Abstract
From the viewpoint of device reliability of a 0.35 nm WSi Gate GaAs heterostructure insulated gate field effect transistors, we studied the effect of the passivation film (SiON)/semiconductor (GaAs) interface stability on device degradation. The degradation discussed here is characterized by an increase in the gate leakage current under a continuous reverse-voltage stress. We proposed a degradation model assuming the hole-trapping centers in the passivation film (SiON)/semiconductor (GaAs) interface. We found that this degradation did not occur after removing the SiON film and that a
plasma surface treatment after the WSi gate dry etching effectively suppressed this degradation. These phenomena suggest the presence of hole-trapping centers in SiON/GaAs interface in the peripheral area of the WSi gate. To clarify the effect of the
plasma surface treatment, GaAs surfaces were inspected using physicochemical analyses. X-ray photoelectron spectroscopy and total reflection X-ray fluorescence revealed that
plasma treatment removed the arsenic compounds, such as
and
which were formed on the GaAs surfaces during the gate dry etching with a gas mixture of
and
These arsenic compounds are considered to be the origin of hole-trapping centers, which cause this degradation. The physicochemical analyses fully support a previously proposed degradation mechanism. © 2001 The Electrochemical Society. All rights reserved.