Papers

8597

, , and

In this paper, procedures to determine compliance of low-frequency pulsed exposures are investigated. Current methods specified by international standards or guidelines (e.g., from the ICNIRP or IEEE) are recognized to be conservative in order to account for uncertainties coming from the assessment procedures. In this way, protection of workers and the general public should be guaranteed. However, overly conservative procedures could hinder the application of technologies employing complex, intermittent, or pulsed waveforms without improving safety. Besides over conservatism, variabilities among the results of several procedures are examined for the first time. These limits pose several concerns on the applicability of the existing compliance formulae. A more stable technique, which is still easy to implement, is therefore proposed.

8609

, , , , , and

Knowledge of x-ray attenuation is essential for developing and evaluating x-ray imaging technologies. For instance, techniques to better characterize cysts at mammography screening would be highly desirable to reduce recalls, but the development is hampered by the lack of attenuation data for cysts. We have developed a method to measure x-ray attenuation of tissue samples using a prototype photon-counting spectral mammography unit. The method was applied to measure the attenuation of 50 samples of breast cyst fluid and 50 samples of water. Spectral (energy-resolved) images of the samples were acquired and the image signal was mapped to equivalent thicknesses of two known reference materials, which can be used to derive the x-ray attenuation as a function of energy. The attenuation of cyst fluid was found to be significantly different from water. There was a relatively large natural spread between different samples of cyst fluid, whereas the homogeneity of each individual sample was found to be good; the variation within samples did not reach above the quantum noise floor. The spectral method proved stable between several measurements on the same sample. Further, chemical analysis and elemental attenuation calculation were used to validate the spectral measurement on a subset of the samples. The two methods agreed within the precision of the elemental attenuation calculation over the mammographic energy range.

8621

, , , and

Organ motion is a major problem for any dynamic radiotherapy delivery technique, and is particularly so for spot scanned proton therapy. On the other hand, the use of narrow, magnetically deflected proton pencil beams is potentially an ideal delivery technique for tracking tumour motion on-line. At PSI, our new Gantry is equipped with a Beams Eye View (BEV) imaging system which will be able to acquire 2D x-ray images in fluoroscopy mode during treatment delivery. However, besides precisely tracking motion from BEVs, it is also essential to obtain information on the 3D motion vector throughout the whole region of interest, and any sparsely acquired surrogate motion is generally not sufficient to describe the deformable behaviour of the whole volume in three dimensions. In this study, we propose a method by which 3D deformable motions can be estimated from surrogate motions obtained using this monoscopic imaging system. The method assumes that example motions over a number of breathing cycles can be acquired before treatment for each patient using 4DMRI. In this study, for each of 11 different subjects, 100 continuous breathing cycles have been extracted from extended 4DMRI studies in the liver and then subject specific motion models have been built using principle component analysis (PCA). To simulate treatment conditions, a different set of 30 continuous breathing cycles from the same subjects have then been used to generate a set of simulated 4DCT data sets (so-called 4DCT(MRI) data sets), from which time-resolved digitally reconstructed radiographs (DRRs) were calculated using the BEV geometry for three treatment fields respectively. From these DRRs, surrogate motions from fiducial markers or the diaphragm have been used as a predictor to estimate 3D motions in the liver region for each subject. The prediction results have been directly compared to the 'ground truth' motions extracted from the same 30 breath cycles of the originating 4DMRI data set. Averaged over all 11 subjects, and for three field directions, for 99% of predicted positions, median (max) error magnitudes of better than 2.63(5.67) mm can be achieved when fiducial markers was chosen as predictor. Furthermore, three single fields, 4D dose calculations have been performed as a verification tool to evaluate the prediction performance of such a model in the context of scanned proton beam therapy. These show a high similarity between plans considering either PCA predicted motion or ground truth motion, where absolute dose differences of more than 5% (Vdosediff = 5%) occur for the worst field scenarios in only 3.61% (median) or 15.13% (max) of dose calculation points in the irradiated volume. The magnitude of these dose differences were insignificantly dependent on whether surrogate motions were tracked by monoscopic or stereoscopic imaging systems, or whether fiducial markers or diaphragm were chosen as surrogate. This study has demonstrated that on-line deformable motion reconstruction from sparse surrogate motions is feasible, even when using only a monoscopic imaging system. In addition, it has also been found that diaphragm motion can be considered as a good predictor for respiratory deformable liver motion prediction, implying that fiducial markers might not be compulsory if used in conjunction with a patient specific PCA based model.

8647

, , and

Valid risk stratification for carotid atherosclerotic plaques represents a crucial public health issue toward preventing fatal cerebrovascular events. Although motion analysis (MA) provides useful information about arterial wall dynamics, the identification of motion-based risk markers remains a significant challenge. Considering that the ability of a motion estimator (ME) to handle changes in the appearance of motion targets has a major effect on accuracy in MA, we investigated the potential of adaptive block matching (ABM) MEs, which consider changes in image intensities over time. To assure the validity in MA, we optimized and evaluated the ABM MEs in the context of a specially designed in silico framework. ABMFIRF2, which takes advantage of the periodicity characterizing the arterial wall motion, was the most effective ABM algorithm, yielding a 47% accuracy increase with respect to the conventional block matching. The in vivo application of ABMFIRF2 revealed five potential risk markers: low movement amplitude of the normal part of the wall adjacent to the plaques in the radial (RMAPWL) and longitudinal (LMAPWL) directions, high radial motion amplitude of the plaque top surface (RMAPTS), and high relative movement, expressed in terms of radial strain (RSIPL) and longitudinal shear strain (LSSIPL), between plaque top and bottom surfaces. The in vivo results were reproduced by OFLK(WLS) and ABMKF-K2, MEs previously proposed by the authors and with remarkable in silico performances, thereby reinforcing the clinical values of the markers and the potential of those MEs. Future in vivo studies will elucidate with confidence the full potential of the markers.

8663
The following article is Open access

, , and

SampLe Interval Modulation-magnetic resonance elastography (SLIM-MRE) is introduced for simultaneously encoding all three displacement projections of a monofrequency vibration into the MR signal phase. In SLIM-MRE, the individual displacement components are observed using different sample intervals. In doing so, the components are modulated with different apparent frequencies in the MR signal phase expressed as a harmonic function of the start time of the motion encoding gradients and can thus be decomposed by applying a Fourier transform to the sampled multidirectional MR phases. In this work, the theoretical foundations of SLIM-MRE are presented and the new idea is implemented using a high field (11.7 T) vertical bore magnetic resonance imaging system on an inhomogeneous agarose gel phantom sample. The local frequency estimation-derived stiffness values were the same within the error margins for both the new SLIM-MRE method and for conventional MRE, while the number of temporally-resolved MRE experiments needed for each study was reduced from three to one. In this work, we present for the first time, monofrequency displacement data along three sensitization directions that were acquired simultaneously and stored in the same k-space.

8677

, , , and

Our aim was to measure the performance of desktop magnetic resonance imaging (MRI) systems using specially designed phantoms, by testing imaging parameters and analysing the imaging quality. We designed multifunction phantoms with diameters of 18 and 60 mm for desktop MRI scanners in accordance with the American Association of Physicists in Medicine (AAPM) report no. 28. We scanned the phantoms with three permanent magnet 0.5 T desktop MRI systems, measured the MRI image parameters, and analysed imaging quality by comparing the data with the AAPM criteria and Chinese national standards. Image parameters included: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, signal-to-noise ratio (SNR), and image uniformity. The image parameters of three desktop MRI machines could be measured using our specially designed phantoms, and most parameters were in line with MRI quality control criterion, including: resonance frequency, high contrast spatial resolution, low contrast object detectability, slice thickness, geometrical distortion, image uniformity and slice position accuracy. However, SNR was significantly lower than in some references. The imaging test and quality control are necessary for desktop MRI systems, and should be performed with the applicable phantom and corresponding standards.

8689
The following article is Open access

, and

In this paper the propagation of a UWB pulse into a layered model of the human body is studied to characterize absorption and reflection of the UWB signal due to the different body tissues. Several time behaviours for the incident UWB pulse are considered and compared with reference to the feasibility of breath and heartbeat activity monitoring. Results show that if the UWB source is placed far from the human body, the reflection coming from the interface between air and skin can be used to detect the respiratory activity. On the contrary, if the UWB source is placed close to the human body, a small reflection due to the interface between the posterior lung wall and the bone, which is well distanced in time from the reflections due to the first layers of the body model, can be used to detect lung and heart changes associated with the cardio-respiratory activity.

8709

, , and

Neutron production is of concern for proton therapy, especially for passive scattering proton beam delivery methods. The levels of neutron dose equivalent vary significantly with system design and treatment parameters. The purpose of this study was to examine neutron dose equivalent per therapeutic dose (H/D) around the Mevion S250 proton therapy system, a novel design of proton therapy systems. The benchmark comparisons between measurement and simulation were found to be within a factor of 2 for most cases. The H/D values were evaluated as a function of various parameters. The results showed that, at a standard reference condition (10 × 10 cm2 field size, distance 1 m detector-to-isocenter lateral to the primary proton beam direction), the H/D values range from 0.72 to 3.37 mSv Gy−1 for all configurations studied. The H/D values generally (1) decreased as the neutron detectors moved away from the isocenter, (2) decreased with increasing aperture field sizes, (3) increased with increasing angle from the initial beam axis and (4) were independent of treatment nozzle position. The H/D trends were consistent with other existing passive scattering proton accelerators reported in the literature.

8725

, , , , , , , , , et al

Adaptive radiation therapy (ART) can reduce normal tissue toxicity and/or improve tumor control through treatment adaptations based on the current patient anatomy. Developing an efficient and effective re-planning algorithm is an important step toward the clinical realization of ART. For the re-planning process, manual trial-and-error approach to fine-tune planning parameters is time-consuming and is usually considered unpractical, especially for online ART. It is desirable to automate this step to yield a plan of acceptable quality with minimal interventions. In ART, prior information in the original plan is available, such as dose–volume histogram (DVH), which can be employed to facilitate the automatic re-planning process. The goal of this work is to develop an automatic re-planning algorithm to generate a plan with similar, or possibly better, DVH curves compared with the clinically delivered original plan. Specifically, our algorithm iterates the following two loops. An inner loop is the traditional fluence map optimization, in which we optimize a quadratic objective function penalizing the deviation of the dose received by each voxel from its prescribed or threshold dose with a set of fixed voxel weighting factors. In outer loop, the voxel weighting factors in the objective function are adjusted according to the deviation of the current DVH curves from those in the original plan. The process is repeated until the DVH curves are acceptable or maximum iteration step is reached. The whole algorithm is implemented on GPU for high efficiency. The feasibility of our algorithm has been demonstrated with three head-and-neck cancer IMRT cases, each having an initial planning CT scan and another treatment CT scan acquired in the middle of treatment course. Compared with the DVH curves in the original plan, the DVH curves in the resulting plan using our algorithm with 30 iterations are better for almost all structures. The re-optimization process takes about 30 s using our in-house optimization engine.

8739

, , , , , , , , , et al

Following cancer radiotherapy, reconstruction of doses to organs, other than the target organ, is of interest for retrospective health risk studies. Reliable estimation of doses to organs that may be partially within or fully outside the treatment field requires reliable knowledge of the location and size of the organs, e.g., the stomach, which is at risk from abdominal irradiation. The stomach location and size are known to be highly variable between individuals, but have been little studied. Moreover, for treatments conducted years ago, medical images of patients are usually not available in medical records to locate the stomach. In light of the poor information available to locate the stomach in historical dose reconstructions, the purpose of this work was to investigate the variability of stomach location and size among adult male patients and to develop prediction models for the stomach location and size using predictor variables generally available in medical records of radiotherapy patients treated in the past. To collect data on stomach size and position, we segmented the contours of the stomach and of the skeleton on contemporary computed tomography (CT) images for 30 male patients in supine position. The location and size of the stomach was found to depend on body mass index (BMI), ponderal index (PI), and age. For example, the anteroposterior dimension of the stomach was found to increase with increasing BMI (≈0.25 cm kg–1 m2) whereas its craniocaudal dimension decreased with increasing PI (≈−3.3 cm kg–1 m3) and its transverse dimension increased with increasing PI (≈2.5 cm kg–1 m3). Using the prediction models, we generated three-dimensional computational stomach models from a deformable hybrid phantom for three patients of different BMI. Based on a typical radiotherapy treatment, we simulated radiotherapy treatments on the predicted stomach models and on the CT images of the corresponding patients. Those dose calculations demonstrated good agreement between predicted and actual stomachs compared with doses derived from a reference model of the body that might be used in the absence of individual CT scan data.

8755

, , , , and

Recent studies have shown the feasibility of estimating patient dose from a CT exam using CTDIvol-normalized-organ dose (denoted as h), DLP-normalized-effective dose (denoted as k), and DLP-normalized-risk index (denoted as q). However, previous studies were limited to a small number of phantom models. The purpose of this work was to provide dose coefficients (h, k, and q) across a large number of computational models covering a broad range of patient anatomy, age, size percentile, and gender. The study consisted of 100 patient computer models (age range, 0 to 78 y.o.; weight range, 2–180 kg) including 42 pediatric models (age range, 0 to 16 y.o.; weight range, 2–80 kg) and 58 adult models (age range, 18 to 78 y.o.; weight range, 57–180 kg). Multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare) were included. A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which h, k, and q were derived. The relationships between h, k, and q and patient characteristics (size, age, and gender) were ascertained. The differences in conversion coefficients across the scanners were further characterized. CTDIvol-normalized-organ dose (h) showed an exponential decrease with increasing patient size. For organs within the image coverage, the average differences of h across scanners were less than 15%. That value increased to 29% for organs on the periphery or outside the image coverage, and to 8% for distributed organs, respectively. The DLP-normalized-effective dose (k) decreased exponentially with increasing patient size. For a given gender, the DLP-normalized-risk index (q) showed an exponential decrease with both increasing patient size and patient age. The average differences in k and q across scanners were 8% and 10%, respectively. This study demonstrated that the knowledge of patient information and CTDIvol/DLP values may be used to estimate organ dose, effective dose, and risk index in abdominopelvic CT based on the coefficients derived from a large population of pediatric and adult patients.

8769

, , , , and

Intra-operative electron radiation therapy (IOERT) combines surgery and ionizing radiation applied directly to an exposed unresected tumour mass or to a post-resection tumour bed. The radiation is collimated and conducted by a specific applicator docked to the linear accelerator. The dose distribution in tissues to be irradiated and in organs at risk can be planned through a pre-operative computed tomography (CT) study. However, surgical retraction of structures and resection of a tumour affecting normal tissues significantly modify the patient's geometry. Therefore, the treatment parameters (applicator dimension, pose (position and orientation), bevel angle, and beam energy) may require the original IOERT treatment plan to be modified depending on the actual surgical scenario. We propose the use of a multi-camera optical tracking system to reliably record the actual pose of the IOERT applicator in relation to the patient's anatomy in an environment prone to occlusion problems. This information can be integrated in the radio-surgical treatment planning system in order to generate a real-time accurate description of the IOERT scenario. We assessed the accuracy of the applicator pose by performing a phantom-based study that resembled three real clinical IOERT scenarios. The error obtained (2 mm) was below the acceptance threshold for external radiotherapy practice, thus encouraging future implementation of this approach in real clinical IOERT scenarios.

Note

N321

, and

Performance analysis of a modified 3D dosimetry optical scanner based on the first generation optical CT scanner OCTOPUS is presented. The system consists of PRESAGE™ dosimeters, the modified 3D scanner, and a new developed in-house user control panel written in Labview program which provides more flexibility to optimize mechanical control and data acquisition technique. The total scanning time has been significantly reduced from initial 8 h to ∼2 h by using the modified scanner. The functional performance of the modified scanner has been evaluated in terms of the mechanical integrity uncertainty of the data acquisition process. Optical density distribution comparison between the modified scanner, OCTOPUS and the treatment plan system has been studied. It has been demonstrated that the agreement between the modified scanner and treatment plans is comparable with that between the OCTOPUS and treatment plans.