Open-circuit durability tests are carried out for intentionally Pt-precipitated membranes with and without electrodes to clarify the roles of Pt-band and the electrodes. The Pt-precipitated membrane without electrodes gives a small but non-zero fluoride emission rate (FER). The Pt-precipitated membrane with electrodes gives the highest FER, which is much higher than that of membrane with electrodes (conventional MEA). Chemically aggressive species are produced on both Pt-band and electrodes. Pt band, without electrodes, is only slightly detrimental for the membrane but, with electrodes, it significantly accelerates membrane degradation.