An environmentally controlled MRI technique was used to investigate the effect of relative humidity and current density on the transverse water content profile in a membrane under fuel cell operation at elevated temperature. MRI visualization revealed that, in the dry condition (40% RH), the water content in the membrane was around 3 and the water content profile was flat. In the wet condition (92% RH), a higher water content of around λ=15 was observed than that at 80% RH, suggesting that the generated water in the cathode catalyst layer was transported to the membrane at 92% RH. A larger water concentration gradient was observed at 0.1A/cm2 with 92% RH than that at 80% RH, suggesting that the larger water content in the membrane induced greater electro-osmotic drag, since the electro-osmosis coefficient was positively correlated with the water content.