AlGaN/GaN high electron mobility transistors (HEMTs) with GaN cap layers were irradiated with high-energy Equation or symbol description not available(17MeV) protons to doses up to Equation or symbol description not available2×1016cm−2. There was no significant degradation in dc electrical parameters such as drain–source current Equation or symbol description not available(IDS) and extrinsic transconductance Equation or symbol description not available(gm) of the HEMTs up to a fluency of Equation or symbol description not available7.2×1013protons/cm2. At the highest dose of Equation or symbol description not available2×1016protons/cm2 there was a decrease of Equation or symbol description not available43% in Equation or symbol description not availableIDS and a Equation or symbol description not available29% decrease in Equation or symbol description not availablegm. The data are consistent with the introduction of defect centers in the HEMT structure by the high-energy protons leading to a reduction in carrier concentration and mobility in the two-dimensional electron gas channel. These results show that AlGaN/GaN HEMTs are attractive for space-based applications where high-energy proton fluxes are present.