Abstract
Concurrent linear sweep voltammetry, coulometry, and electrochemical quartz crystal microgravimetry (EQCM) were used, we believe for the first time, to study anodic corrosion layers at lead. These corrosion layers were first generated on the lead surface at 0.8 V (vs.
.
reference) either in 4.5M
or 0.1M
. A subsequent cathodic voltammetry scan revealed waves due to the reduction of the corrosion layer. Coulometry and EQCM analyses were then performed within the potential window corresponding to each cathodic wave. From these charge and mass measurements respectively, an
parameter (
,
difference between solid products and reactants) could be extracted and compared with the value computed for a model reaction candidate. We thus show that basic lead sulfates can be detected in the presence of both
and
. Thus
is shown to be a corrosion product in 4.5M
while
is generated at the lead surface in 0.1M
.