The ability of poly(p‐xylyl‐viologen) adsorbed on gold to block solute transport is strongly affected by film solvation and the electrolyte counterion. Permeability measurements with hydroxymethyl ferrocene and Equation or symbol description not availableRu(NH3)6+2 imply controlled solute permeation/diffusion rather than a partially blocked electrode. Electrostatic effects on calculated double layer potentials adequately rationalize the observed decrease in heterogeneous electron transfer rate.