Paper The following article is Open access

Study on the Smoke Spread Law of a Subway Tunnel Fire under the Synergistic Action of Shaft Smoke Exhaust and Longitudinal Ventilation

, , and

Published under licence by IOP Publishing Ltd
, , Citation H Zhang et al 2020 IOP Conf. Ser.: Earth Environ. Sci. 544 012005 DOI 10.1088/1755-1315/544/1/012005

1755-1315/544/1/012005

Abstract

Urban rail transit improves the urban spatial structure, solves the problem of urban traffic congestion, so its safety problem can not be ignored. Fire is one of the major factors threatening the safety of urban rail transit. Taking the tunnel between wengjiao road and Maqing road of Xiamen Rail Transit Line 2 as an example, the paper uses FDS software to simulate the mechanical smoke exhaust of the shaft under different wind speed conditions of the main tunnel, and deeply analyzes the smoke and temperature distribution under the fire conditions of the tunnel with the shaft. The results show that when the longitudinal wind speed v=1.7m/s and the shaft uses mechanical exhaust, there is no smoke upstream of the fire source, all the smoke is discharged through the shaft, and the height of the flue gas layer is significantly smaller than the thickness of the flue gas layer without longitudinal ventilation. The combination of longitudinal wind and mechanical smoke exhaust is more conducive to the safe evacuation of people.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.
10.1088/1755-1315/544/1/012005