Table of contents for issue 5, volume 6, Biomedical Physics & Engineering Express

Volume 6

Number 5, September 2020

Previous issueNext issue

Buy this issue in print

    Paper

  • 055001
    The following article is Open access

    and

    Purpose: To identify the relative positions of the ultimate RBE, at a LET value of LETU (where the LET-RBE turnover point occurs independently of dose), and of the maximum LET (LETM) for a range of ions from protons to Iron ions. Methods: For a range of relativistic velocities (β), the kinetic energies, LET values and ranges for each ion are obtained using SRIM software. For protons and helium ions, the LET changes with β are plotted and LETM is compared with LETU. For all the ions studied the residual ranges of particles at LETU and LETM are subtracted to provide the physical separation (S) between LETU and LETM. Results: Graphical methods are used to show the above parameters for protons and helium ions. For all the ions studied, LETU occurs at kinetic energies which are higher than those at LETM, so the ultimate maximal RBE occurs proximal to the Bragg peak for individual particles and not beyond it, as is commonly supposed. The distance S, between LETU and LETM, appears to increase linearly with the atomic charge value Z. Conclusions: For the lighter elements, from protons to carbon ions, S is sufficiently small (less than the tolerance/accuracy of radiation treatments) and so will probably not influence therapeutic decisions or outcomes. For higher Z numbers such as Argon and Iron, larger S values of several centimetres occur, which may have implications not only in any proposed therapeutic beams but also at very low doses encountered in radiation protection where the few cells that are irradiated will typically be traversed by a single particle.

  • 055002

    , , and

    Particle radiography (pRad) has been proposed and investigated as a promising tool for particle therapy as it provides a water equivalent thickness (WET) image of the patient. In single-event particle imaging, for each measured particle, the related most likely path (MLP) through the object is estimated to account for multiple Coulomb scattering (MCS). In previous studies, the accuracy limit of the MLP has been used to determine the spatial resolution limit. In this work, we investigate the limit of the spatial resolution achievable with different pRad algorithms based on a theoretical model of the particle scattering for an ideal beam and detector. First, we investigate binning the particles in a plane seated at the depth of the object of interest (plane-of-interest binning; PIB) and extend existing theoretical considerations also to objects not located in the binning plane. We use this to model the spatial resolution in case of binning the particles directly at the front or rear tracker (FTB and RTB, respectively). Further, we investigate evenly distributing the particles’ WET along their trajectory into pixel channels and creating the pRad image as channel mean (along-path-binning; APB). Monte Carlo simulations are used to qualitatively investigate the different algorithms and to validate the theoretical predictions. We show that projecting the scattered particle paths onto a single image will inevitably result in a limited spatial resolution lower than expected from only the MLP uncertainty. Only in the case where the depth of a feature is known and used as binning depth for PIB, the spatial resolution of that feature is equal to the path estimation accuracy. For the APB algorithm the spatial resolution decreases with increasing depth in the object, especially if the true particle path through the object would be known. The derived theoretical models will be useful for future development of improved pRad reconstruction algorithms.

  • 055004

    , , , , , , and

    New bioactive scaffolds with improved mechanical properties, biocompatibility and providing structural support for bone tissue are being developed for use in the treatment of bone defects. In this study, we have synthesized bioactive scaffolds consisting of biphasic calcium phosphate (BCP) and zirconia-Mullite (2ZrO2·[3Al2O3 ·2 SiO2] (ZAS)) (BCPZAS) combined with polymers matrix of polycaprolactone (PCL)-alginate (Alg)-chitosan (Chi) (Chi/Alg-PCL) (BCPZAS@Chi/Alg-PCL). The composite material scaffolds were prepared by a blending technique. The microstructure, mechanical, bioactivity and in vitro biological properties with different ratios of BCP to ZAS of 1:0, 3:1, 1:1, 1:3 and 0:1 wt% in polymer matrix were analyzed. Microstructure analysis showed a successful incorporation of the BCPZAS particles with an even distribution of them within the polymer matrix. The mechanical properties were found to gradually decrease with increasing the ratio of ZAS particles in the scaffolds. The highest compressive strength was 42.96 ± 1.01MPa for the 3:1 wt% BCP to ZAS mixing. Bioactivity test, the BCPZAS@Chi/Alg-PCL composite could induce apatite formation in simulate body fluid (SBF). In-vitro experiment using UMR-106 osteoblast-like cells on BCPZAS@Chi/Alg-PCL composite scaffold showed that there is cell attachment to the scaffolds with proliferation. These experimental results demonstrate that the BCPZAS@Chi/Alg-PCL composite especially for the BCP:ZAS at 3:1 wt% could be utilized as a scaffold for bone tissue engineering applications.

  • 055005

    , and

    In this paper, we utilized functional near-infrared spectroscopy (fNIRS) technology to examine the hemodynamic responses in the motor cortex for two conditions, namely standing and sitting tasks. Nine subjects performed five trials of standing and sitting (SAS) tasks with both real movements and imagery thinking of SAS. A group level of statistical parametric mapping (SPM) analysis during these tasks showed bilateral activation of oxy-hemoglobin for both real movements and imagery experiments. Interestingly, the SPM analysis clearly revealed that the sitting tasks induced a higher oxy-hemoglobin level activation compared to the standing task. Remarkably, this finding is persistent across the 22 measured channels at the individual and group levels for both experiments. Furthermore, six features were extracted from pre-processed HbO signals and the performance of four different classifiers was examined in order to test the viability of using SAS tasks in future fNIRS-brain-computer interface (fNIRS-BCI) systems. In particular, two features-combination tests revealed that the signal slope with signal variance represents one of the three best two-combined features for its consistency in providing high accuracy results for both real and imagery experiments. This study shows the potential of implementing such tasks into the fNIRS-BCI system. In the future, the results of this work could pave the way towards the application of fNIRS-BCI in lower limb rehabilitation.

  • 055006
    The following article is Open access

    , and

    This work presents a novel architecture, exemplified for electrophysiological applications like ECoG that can be used to detect Epilepsy. The new ECoG is based on a mixed analog-digital architecture (Pulse Amplitude Modulation PAM), that allows the use of thousands of electrodes for recording. Whilst the increased number of electrodes helps to refine the spatial resolution of the medical application, the transmission of the signals from the electrodes to an external analysing device appears to be a bottleneck. To overcoming this, our work presents a hardware architecture and corresponding protocol for a mixed architecture that improves the information density between channels and their signal-to-noise ratio. This is shown by the correlation between the input and the transmitted signals in comparison to a classical digital transmission (Pulse Code Modulation PCM) system. We show in this work that it is possible to transmit the signals of 10 channels with a analog-digital architecture with the same quality of a full digital architecture.

  • 055007

    Diffusion tensor imaging (DTI) and diffusion kurtosis imaging (DKI) analyses of diffusion-weighted magnetic resonance imaging (MRI) show that diffusional fractional anisotropy (FA) and kurtosis anisotropy (KA) of water inside brain white matter decrease for schizophrenic patients from that for healthy persons. DTI and DKI are statistical approaches and do not directly point to the underlying neurobiological reasons. In schizophrenia, it is believed that the demyelination of axons—microstructures that constitute the brain white matter—increases lateral diffusion of water and causes defective neural communications, resulting cognitive processing-speed deficits. Here, we use a simple but realistic neurobiological model for brain white matter and solve the Bloch-Torrey equation using numerical finite-element method to find out the underlying reasons of cognitive deficits in schizophrenia. FA and KA are calculated from computationally obtained diffusion-weighted MRI data after a Stejskal-Tanner gradient pulse sequence is applied to a periodic array of tubular axons with circular cross-sections. The calculated FA and KA decrease when the axon walls are more permeable to water, agree with the experimental findings, and correlate with the cognitive processing speeds of healthy persons and schizophrenic patients, and thus, help to understand the underlying reasons of cognitive processing-speed deficits in schizophrenia.

  • 055008

    , and

    The efficacy of synthetic polymers as hydrogel phantoms for radiation therapy and dosimetry has been investigated for photon and charged particle (electron, proton and alpha particle) interactions. Tissue equivalence has been studied in terms of photon mass energy-absorption coefficients, KERMA (kinetic energy released per unit mass), equivalent atomic number and energy absorption build-up factors, relative to human tissues (skin, soft tissue, cortical bone and skeletal muscle), in the energy range 0.015–15 MeV. For charged particle interactions, ratio of effective atomic number is examined for tissue-equivalence in the energy region of 10 keV–1 GeV. Well established theoretical formulations are used for computation of photon mass-energy absorption effective atomic number, electron density and KERMA. Five-parameter geometric progression (G-P) fitting approximation is used to compute the values of energy absorption build-up factors. Effective atomic number for charged particle interaction is determined using logarithmic interpolation method. Using the analytical methodology, it has been revealed that all the selected synthetic polymers have good tissue-equivalence relative to all tissue except cortical bone. In particular, polyglycolic acid (PGA) and poly-lactic-co-glycolic acid (PLGA) prove to be best substitute material for photon interactions. On the other hand, % difference between effective atomic number for charged particle relative to human tissues is found least for polyethylene glycol (PEG) demonstrating adequate tissue-equivalence. Therefore, the present study is expected to be useful to choose most appropriate phantom material for radiation therapy.

  • 055009

    , , , , and

    Heart mediastinal and epicardial fat tissues are related to several adverse metabolic effects and cardiovascular risk factors, especially coronary artery disease (CAD). The manual segmentation of those fats is that the high dependence on user intervention and time-consuming analyzes. As a result, the automated measurement of cardiac fats could be considered as one of the most important biomarkers for cardiovascular risks in imaging and medical visualization by physicians. In this paper, we validate an automatic approach for the cardiac fat segmentation in non-contrast CT images then investigate the correlation between cardiac fat volume and CAD using the association rule mining algorithm. The pre-processing step includes threshold and contrast enhancement, the feature extraction step includes Gabor filter bank based on GLCM, the cardiac fat segmentation step is predicated on pattern recognition classification algorithms, and eventually, the step of investigating the relationship between cardiac fat volume and CAD is using FP-Growth algorithm. Experimental validation using CT images of two databases points to a good performance in cardiac fat segmentation. Experiments showed that the accuracy of the designed algorithm using the ensemble classifier with the best performance over other classifiers for the cardiac fat segmentation was 99.2%, with a sensitivity of 96.3% and a specificity of 99.8%. The results of using the FP-Growth algorithm showed that the low volume of epicardial (Confidence = 0.6818, Lift = 1.0626) and mediastinal (Confidence = 0.6696, Lift = 1.0436) fat are associated with healthy individuals and the high volume of epicardial (Confidence = 0.8, Lift = 2.2326) and mediastinal (Confidence = 0.75, Lift = 2.093) fat are related to individuals of CAD. As a result, cardiac fats can be used as a reliable biomarker tool in predicting the extent of CAD stenosis.

  • 055010

    , , and

    Nuclear medicine is the second largest source of medical radiation exposure to the general population after computed tomography imaging. Informed decisions regarding the use of nuclear medicine procedures require a better understanding of the magnitude of radiation dose and associated health risks. However, existing model-based organ dose estimation tools rely on simplified human anatomy models or commercial programs. Therefore, we developed a publicly-available dose calculation tool based on more sophisticated human anatomy models. We calculated a comprehensive library of photon and electron specific absorbed fractions (SAF) for multiple combinations of source and target regions within a series of pediatric and adult computational human phantoms matching the International Commission on Radiological Protection (ICRP)’s reference data, combined with a Monte Carlo radiation transport code. Then, we derived a library of S values from these SAFs and the nuclear decay data from ICRP Publication 107. Finally, we created a graphical user interface, named National Cancer Institute Dosimetry System for Nuclear Medicine (NCINM), to facilitate the dosimetry process. Approximately 13 million S values were derived from 2 million SAFs computed in this work. Comprehensive comparisons were conducted at different steps of the dosimetry chain with data available in software OLINDA/EXM 1.0 and IDAC 2.1. For instance, median ratios of photon self-absorption SAFs available from OLINDA/EXM 1.0 and IDAC 2.1 to those calculated in this study were 1.3 (interquartile range = 1.1–1.6) and 1.0 (interquartile range = 0.98–1.0), respectively. SAF differences between NCINM and OLINDA/EXM 1.0 were explained by the large inter-phantom anatomical variability. Our results illustrate the importance of realistic human anatomy models for use in dosimetry software. More phantoms and radionuclides, as well as a biokinetic module, will soon be added. Applications of the NCINM program include computation of absorbed doses for use in radiation epidemiologic studies and patient dose monitoring in nuclear medicine.

  • 055011
    The following article is Open access

    , , , , , , and

    Computed tomography (CT) is the reference method for cardiac imaging, but concerns have been raised regarding the radiation dose of CT examinations. Recently, photon counting detectors (PCDs) and interior tomography, in which the radiation beam is limited to the organ-of-interest, have been suggested for patient dose reduction. In this study, we investigated interior PCD-CT (iPCD-CT) for non-enhanced quantification of coronary artery calcium (CAC) using an anthropomorphic torso phantom and ex vivo coronary artery samples. We reconstructed the iPCD-CT measurements with filtered back projection (FBP), iterative total variation (TV) regularization, padded FBP, and adaptively detruncated FBP and adaptively detruncated TV. We compared the organ doses between conventional CT and iPCD-CT geometries, assessed the truncation and cupping artifacts with iPCD-CT, and evaluated the CAC quantification performance of iPCD-CT. With approximately the same effective dose between conventional CT geometry (0.30 mSv) and interior PCD-CT with 10.2 cm field-of-view (0.27 mSv), the organ dose of the heart was increased by 52.3% with interior PCD-CT when compared to CT. Conversely, the organ doses to peripheral and radiosensitive organs, such as the stomach (55.0% reduction), were often reduced with interior PCD-CT. FBP and TV did not sufficiently reduce the truncation artifact, whereas padded FBP and adaptively detruncated FBP and TV yielded satisfactory truncation artifact reduction. Notably, the adaptive detruncation algorithm reduced truncation artifacts effectively when it was combined with reconstruction detrending. With this approach, the CAC quantification accuracy was good, and the coronary artery disease grade reclassification rate was particularly low (5.6%). Thus, our results confirm that CAC quantification can be performed with the interior CT geometry, that the artifacts are effectively reduced with suitable interior reconstruction methods, and that interior tomography provides efficient patient dose reduction.

  • 055012

    , and

    It has been reported that when a grounded human is exposed to an electric field at power frequency, a short-circuit current flowing from the feet to the ground is proportional to the square of his or her height. The current, however, should also vary with the body surface area, that is, body shape, even in people with the same height. In the present study, we confirmed this hypothesis using an analytical solution derived from a semi-ellipsoidal model. The short-circuit currents were calculated for various numerical human body models in which the horizontal length of a voxel was varied from 1.8 to 3.0 mm, and the results for different body shapes were compared. Finally, we derived an approximate expression for estimating the short-circuit current from the left-right width (2b), frontal thickness (2c), and height (a) of a human from the analytical solution. The short-circuit currents obtained from the approximate expression are consistent with those obtained from numerical calculations for 48 differently shaped human body models with a correlation coefficient of 0.9942. Hence, we concluded that the short-circuit current can be determined depending on the similarity ratio (a/b) and the ellipticity ratio (c/b) of the human body as well as the height. This finding is consistent with the numerical human body models that have been used previously, in which the similarity and ellipticity ratios were very close. Therefore, we can make the limited conclusion that the short-circuit current is proportional only to the square of the height. Additionally, numerical calculations showed that the short-circuit current is the same whether one foot or both feet are grounded.

  • 055003

    Objective: To investigate the association between subjective pain intensity and objective parameters obtained from two autonomic function tests in a longitudinal study targeting acute pain model in otolaryngology-head and neck region: pupillary light reflex (PLR) and heart rate variability (HRV). Approach: We enrolled 35 patients with acute otolaryngology—head and neck region inflammatory disorders at pre-treatment stage. The acute inflammatory disorders were defined as acute tonsillitis, peritonsillar abscess, acute epiglottitis, acute sinusitis, and deep neck space abscess. Patients underwent a numeric rating scale (NRS) to monitor subjective pain intensity, PLR, and HRV as objective tests at 4 time-points during the follow-up term. As main outcome variables, we used 15 analyzable PLR/HRV parameters. To improve robustness of conclusions about the association between NRS and PLR/HRV parameters, we prepared four linear mixed-effects models (LMMs) including predictor variables such as NRS, sociodemographic factors, and individual variability. And then, we selected the better-fit model based on the lowest Akaike’s information criterion. Main results: NRS significantly decreased due to treatments. In 14 out of 15 parameters, better-fit models were models including not only sociodemographic factors but also individual variability. We observed significant parameter alterations to one unit change of NRS in five PLR and four HRV parameters. Significance: The current study revealed that PLR/HRV parameters can be used as biomarkers reflecting pain relief effects. In addition, the findings suggest the importance of adjusting predictor variables, especially individual variability defined as random effects in LMMs, for obtaining more accurate parameter estimation in the longitudinal study.

  • 055013

    , , and

    We present an open-source platform to aid medical dosimetrists in preventing collisions between gantry head and patient or couch during photon or particle beam therapy treatment planning. This generic framework uses the native scripting interface of the particular planning software to import STL files of the treatment machine elements. These are visualized in 3D together with the contoured or scanned patient surface. A graphical dialog with sliders allows the interactive rotation of the gantry and couch, with real-time feedback. To prevent a future replanning, treatment planners can assess in advance and exclude beam angles resulting in a potential risk of collision. The software platform is publicly available on GitHub and has been validated for RayStation with actual patient plans. Furthermore, the incorporation of the complete patient geometry was tested with a 3D surface scan of a full-body phantom performed with a handheld smartphone. With this study, we aim at minimizing the risk of replanning due to collisions and thus of treatment delays and unscheduled consumption of manpower. The clinical workflow can be streamlined at no cost already at the treatment planning stage. By ensuring a real-time verification of the plan feasibility, the script might boost the use of optimal couch angles that a planner might shy away from otherwise.

  • 055014

    , and

    We propose a new methodology for the fabrication and evaluation of scintillating detector elements using a consumer grade fusion deposition modeling (FDM) 3D printer. In this study we performed a comprehensive investigation into both the effects of the 3D printing process on the scintillation light output of 3D printed plastic scintillation dosimeters (PSDs) and their associated dosimetric properties. Fabrication properties including print variability, layer thickness, anisotropy and extrusion temperature were assessed for 1 cm3 printed samples. We then examined the stability, dose linearity, dose rate proportionality, energy dependence and reproducibility of the 3D printed PSDs compared to benchmarks set by commercially available products. Experimental results indicate that the shape of the emission spectrum of the 3D printed PSDs do not show significant spectral differences when compared to the emission spectrum of the commercial sample. However, the magnitude of scintillation light output was found to be strongly dependent on the parameters of the fabrication process. Dosimetric testing indicates that the 3D printed PSDs share many desirable properties with current commercially available PSDs such as dose linearity, dose rate independence, energy independence in the MV range, repeatability, and stability. These results demonstrate that not only does 3D printing offer a new avenue for the production and manufacturing of PSDs but also allows for further investigation into the application of 3D printing in dosimetry. Such investigations could include options for 3D printed, patient-specific scintillating dosimeters that may be used as standalone dosimeters or incorporated into existing 3D printed patient devices (e.g. bolus or immobilization) used during the delivery of radiation therapy.

  • 055015

    , , , , , , , , and

    Celiac disease is an autoimmune disorder represented by the ingestion of the gluten protein usually found in wheat, barley and rye. To date, ELISA has been the most accurate method for determining the presence of anti-gliadin, which is cumbersome, expensive (compared to a suspension microarray technique), and requires extensive sample preparation. In this study, in order to establish a more accurate assay to identify gliadin at lower concentrations, optical nano biosensors using an indirect immunoassay method for gliadin detection was designed and fabricated. For this, polycaprolactone (PCL) nano- to micro-beads were fabricated as a platform for the gliadin antigen which were optimized and nano functionalized with amine groups for such purposes. The gliadin antibody, which is selective to gliadin, was then added to the beads. Static light scattering tests were conducted to determine PCL particle size distribution and sizes were found from 0.1 to 30 μm, which is suitable for flowcytometry detection devices. Anti-gliadin detection was performed using an anti IgG mouse antibody conjugated with FITC in a flow cytometry device to detect the smallest particle. Fluorescence intensity was investigated at different concentrations of anti-gliadin and a standard curve used to determine gluten concentration based on fluorescence intensity. Results showed that the fluorescence intensity increased with greater concentrations of anti-gliadin providing a very effective method of detection due to selectivity at a 5 ppm detection limit. This represents a new highly sensitive and fast method for anti-gliadin detection. Further, the disuse of a cross linker and the use of a dedicated antibody at a very low level (1 μl) made this new method very economical to identify anti-gliadin concentrations at the nano level. In summary, this study provides a new, more accurate and sensitive, as well as less expensive system to detect anti-gliadin for the improved diagnosis of celiac disease.

  • 055016
    The following article is Open access

    and

    It is thought that osteoarthritis is one of the world’s leading causes of disability, with over 8.75 million people in the UK alone seeking medical treatment in 2013. Although a number of treatments are currently in use, a new wave of tissue engineered structures are being investigated as potential solutions for early intervention. One of the key challenges seen in cartilage tissue engineering is producing constructs that can support the formation of articular cartilage, rather than mechanically inferior fibrocartilage. Some research has suggested that mimicking structural properties of the natural cartilage can be used to enhance this response. Herein directional freezing was used to fabricate scaffolds with directionally aligned pores mimicking the mid-region of cartilage, anti-freeze proteins were used to modify the porous structure, which in turn effected the mechanical properties. Pore areas at the tops of the scaffolds were 180.46 ± 44.17 μm2 and 65.66 ± 36.20 μm2 for the AFP free and the AFP scaffolds respectively, and for the bases of the scaffolds were 91.22 ± 19.05 μm2 and 69.41 ± 21.94 μm2 respectively. Scaffolds were seeded with primary bovine chondrocytes, with viability maintained over the course of the study, and regulation of key genes was observed.

  • 055017

    , , , , , and

    Polymer gel dosimeters are instrumental for clinical and research applications in radiotherapy. These dosimeters possess the unique ability to record dose distribution in three dimensions. A Polymer gel dosimeter is composed of organic molecules in a gel matrix, which upon irradiation polymerize to form a conjugated polymer with optical absorbance proportional to the irradiated dose. Other required characteristics of a radiotherapy clinical dosimeter are soft-tissue equivalency, linear dose-response in a range of clinical treatments, and long term stability for the duration of the analysis. The dosimeter presented in this paper is based on diacetylene bearing fatty acid aggregates embedded in a soft-tissue equivalent gel matrix, Phytagel™, which upon irradiation polymerize to form a blue phase polydiacetylene with a strong optical absorption. Initial characterization showed that PDA-gel irradiated with 160 kV x-ray responded linearly to the irradiated dose, and the calculated diffusion coefficient is $6\cdot {10}^{-3}\tfrac{{{\rm{mm}}}^{2}}{{\rm{Hr}}}$ what is very low. It was also found that the percentage depth dose (PDD) curve of the PDA-gel in a 4 × 4 cm2 field, irradiated with 6 MV x-rays, was with good agreement with the literature. PDA-gel has the potential to detect absorbed dose in a range of clinical radiological irradiation regimes.

  • 055018

    , , , , , , , and

    A complex neutron spectrum generated along with a useful photon beam imposes an additional radiation protection risk around medical linear accelerators (linac). The thermal neutron component of this complex neutron spectrum formed during different photon modes of operation of Elekta Versa HD linac has been quantified using Indium foil activation technique. The thermal neutron fluence (Φth) at isocenter for 15 MV, 10 MV and 10 MV FFF beams was found to be 2.45 × 105, 4.35 × 104 and 3.2 × 104 neutrons cm−2 Gy−1, respectively. The analysis shows a reduction in the Φth as the flattening filter is being taken out from the beam path. A negative correlation in Φth with respect to field size has been observed with an average 18% reduction in Φth per monitor units as field size changes from 10 cm × 10 cm to 40 cm × 40 cm. For particular field size and photon energy, Φth was found to be uniform across the patient plane. From the measured gamma ray spectrum inside the treatment room six major isotopes have been identified which were 122Sb, 187W, 82Br, 56Mn, 24Na and 28Al.

  • 055019

    , and

    This paper describes a novel strategy for the hemocompatibility improvement of poly(ethylene-co-vinyl alcohol) (EVAL) membranes by incorporation of a naturally occurring zwitterion, glycine. Crystalline glycine was directly integrated to the EVAL fibers via electrospinning. The membranes were characterized by Attenuated Total Reflection—Fourier Transform Infrared spectroscopy (ATR-FTIR), Scanning Electron Microscopy (SEM), Water Contact Angle measurements (WCA) and measurement of Critical Wetting Surface Tension (CWST). The impact of glycine integration on the membrane parameters was assessed by variations in fiber diameter, pore size and percentage porosity. The release of glycine from the membranes was also quantitatively evaluated by ninhydrin assay. The interplay of zwitterion structural features on the blood compatibility was studied by in vitro hemocompatibility evaluation and blood filtration studies. The outcomes of these investigations highlight that glycine incorporated membranes offer greater hemocompatibility than virgin EVAL membranes in terms of reduced hemolysis, increased RBC retention, decreased adhesion and activation of platelets. The type of membrane modification can be considered in future for the development of leukodepletion filter membranes.

  • 055020

    , , , and

    One possible application of Near Infrared techniques is to analyze human brain metabolic activity. Currently used models take into account the layered structure of the human head but, usually, they do not consider the non-planar surface of some of the boundaries, i.e. gray matter, which results in a much more complex structure, thus leading to more sophisticated models and longer calculation times. The main objective of this work is to determine if it is worth to replace a planar layered structure by a non-planar one. To this end we implement a Bayesian-based quantitative methodology for choosing between two competitive models describing light propagation in layered turbid media. Experiments of time-resolved diffuse reflectance measurements are performed in layered phantoms and complemented with numerical calculations. The resulting Distributions of Time of Flight of both models are compared using Bayesian model selection analysis. The non-planar interface was introduced in the simulations by a simple surface parametrization. Results suggest that, under certain conditions, a multilayer model with planar boundaries is good enough.

  • 055021
    The following article is Open access

    , , , , , , , , , et al

    Objectives: To study whether a dual-layer spectral CT scout scan-based areal BMD estimation method, called Spectral-detector based x-ray absorptiometry (SDXA), can differentiate patients with versus without osteoporotic fractures. Methods: The ability of the method to differentiate patients with osteoporosis was evaluated by assessing the areal BMD at the spine (L1 to L4) in a group of 19 patients presenting at least one fracture and comparing these results to the areal BMD of age- and gender-matched controls (57 patients). Finally, the reproducibility of SDXA was evaluated in-vivo through the calculation of coefficients of variation (CV), using three repeated analyses performed on each patient. Results: The average areal BMD of patients presenting fractures, measured with the scout scan-based method (0.86 ± 0.17 g cm−2), was found to be significantly lower than the average BMD of the control group (1.00 ± 0.17 g cm−2, p = 0.043). The reproducibility of the method in-vivo was found to be reasonable, with CVs ranging between 3.1 and 6.9%. Conclusions: The results illustrate that the SDXA method for DXA-equivalent areal BMD estimation -delivers the ability to distinguish patients presenting osteoporotic fractures. Considering the total number of CT examinations worldwide, SDXA could develop to be a useful tool for truly opportunistic osteoporosis screening for a future clinical day-to-day routine.

  • 055022

    , and

    Alzheimer’s Disease (AD) begins several years before the symptoms develop. It starts with Mild Cognitive Impairment (MCI) which can be separated into Early MCI and Late MCI (EMCI and LMCI). Functional connectivity analysis and classification are done among the different stages of illness with Functional Magnetic Resonance Imaging (fMRI). In this study, in addition to the four stages including healthy, EMCI, LMCI, and AD, the patients have been tracked for a year. Indeed, the classification has been done among 7 groups to analyze the functional connectivity changes in one year in different stages. After generating the functional connectivity graphs for eliminating the weak links, three different sparsification methods were used. In addition to simple thresholding, spectral sparsification based on effective resistance and sparse autoencoder were performed in order to analyze the effect of sparsification routine on classification results. Also, instead of extracting common features, the correlation matrices were reshaped to a correlation vector and used as a feature vector to enter the classifier. Since the correlation matrix is symmetric, in another analysis half of the feature vector was used, moreover, the Genetic Algorithm (GA) also utilized for feature vector dimension reduction. The non-linear SVM classifier with a polynomial kernel applied. The results showed that the autoencoder sparsification method had the greatest discrimination power with the accuracy of 98.35% for classification when the feature vector was the full correlation matrix.

  • 055023

    , , and

    A novel model of the skin dose in whole-body UV phototherapy treatment cabins is presented. The model is based on an analysis of the thermal radiation exchange between two surfaces, in this case the UV source and the patient. It is shown to allow analytical treatment of the multiple internal reflections in a treatment cabin that account for around 40% of the skin irradiance. The model provides predictions of the absolute irradiance at the skin and shielding factors in seven different UVA and NB-UVB cabins that are within 6% of those measured using a calibrated radiometer and within 12% for all nine cabins. The model predicts reducing skin irradiances with increasingly patient size, a trend demonstrated in clinical measurements. The exact sensitivity to patient size in automated cabin dosimetry systems, however, varies with in-built sensor positioning. The potential to extend the use of the model to investigate improved design of automated dosimetry systems is discussed.

  • 055024

    , and

    The successful development of the image denoising techniques for low-dose computed tomography (LDCT) was largely owing to the public-domain availability of spatially-aligned high- and low-dose CT image pairs. Even though low-dose CT scans are also highly desired in dental imaging, public-domain databases of dental CT image pairs have not been established yet. In this paper, we propose a dental CT image denoising method based on the transfer learning of a generative adversarial network (GAN) from the public-domain CT images. We trained a generative adversarial network with the Wasserstein loss function (WGAN) using 5,100 high- and low-dose medical CT image pairs of human chest and abdomen. For the generative network of GAN, we used the U-net structure of five stages to exploit its high computational efficiency. After training the proposed network, named U-WGAN, we fine-tuned the network with 3,006 dental CT image pairs of two different human skull phantoms. For the high- and low-dose scans of the phantoms, we set the tube current of the dental CT to 10 mA and 4 mA, respectively, with the tube voltage set to 90 kVp in both scans. We applied the trained network to denoising of low-dose dental CT images of dental phantoms and adult humans. The U-net processed images showed over-smoothing effects even though U-net had a good performance in the quantitative metrics. U-WGAN showed similar denoising performance to WGAN, but it reduced the computation time of WGAN by a factor of 10. The fine-tuning procedure in the transfer learning scheme enhanced the network performance in terms of the quantitative metrics, and it also improved visual appearance of the processed images. Even though the number of fine-tuning images was very limited in this study, we think the transfer learning scheme can be a good option for developing deep learning networks for dental CT image denoising.

  • 055025

    and

    Neurofilaments (NFs) are the most abundant cytoskeletal filaments undergoing ‘slow axonal transport’ in axons, and the population of NFs determines the axonal morphology. Both in vitro and ex-vivo experimental evidences show that the caliber of node is much thinner and the number of NFs in the node is much lower than the internode. Based on the Continuity equation, lower population of NFs indicates faster transport velocity. We propose that the local acceleration of NFs transport at node may result from the higher on-track rate ${\gamma }_{on}$ or higher transition rate ${\gamma }_{01}$ from pausing to running. We construct a segment of axon including both node and internode, and inject NFs by a fixed flux into it continuously. By upregulating transition rate of either ${\gamma }_{on}$ or ${\gamma }_{01}$ locally at the Node of Ranvier in the ‘6-state’model, we successfully accelerate NFs velocity and reproduce constriction of nodes. Our work demonstrates that local modulation of NF kinetics can change NFs distribution and shape the morphology of Node of Ranvier.

  • 055026

    , , , , and

    The human body contains approximately 20 billion individual blood vessels that deliver nutrients and oxygen to tissues. While blood flow is a well-developed field of research, no previous studies have calculated the blood flow rates through more than 5 million connected vessels. The goal of this study was to test if it is computationally feasible to calculate the blood flow rates through a vasculature equal in size to that of the human body. We designed and implemented a two-step algorithm to calculate the blood flow rates using principles of steady-state fluid dynamics. Steady-state fluid dynamics is an accurate approximation for the microvascular and venous structures in the human body. To determine the computational feasibility, we measured and evaluated the execution time, scalability, and memory usage to quantify the computational requirements. We demonstrated that it is computationally feasible to calculate the blood flow rate through 17 billion vessels in 6.5 hours using 256 compute nodes. The computational modeling of blood flow rate in entire organisms may find application in research on drug delivery, treatment of cancer metastases, and modulation of physiological performance.

  • 055027

    , , , and

    Vasculature is necessary to the healthy function of most tissues. In radiation therapy, injury of the vasculature can have both beneficial and detrimental effects, such as tumor starvation, cardiac fibrosis, and white-matter necrosis. These effects are caused by changes in blood flow due to the vascular injury. Previously, research has focused on simulating the radiation injury of vasculature in small volumes of tissue, ignoring the systemic effects of local damage on blood flow. Little is known about the computational feasibility of simulating the radiation injury to whole-organ vascular networks. The goal of this study was to test the computational feasibility of simulating the dose deposition to a whole-organ vascular network and the resulting change in blood flow. To do this, we developed an amorphous track-structure model to transport radiation and combined this with existing methods to model the vasculature and blood flow rates. We assessed the algorithm’s computational scalability, execution time, and memory usage. The data demonstrated it is computationally feasible to calculate the radiation dose and resulting changes in blood flow from 2 million protons to a network comprising 8.5 billion blood vessels (approximately the number in the human brain) in 87 hours using a 128-node cluster. Furthermore, the algorithm demonstrated both strong and weak scalability, meaning that additional computational resources can reduce the execution time further. These results demonstrate, for the first time, that it is computationally feasible to calculate radiation dose deposition in whole-organ vascular networks. These findings provide key insights into the computational aspects of modeling whole-organ radiation damage. Modeling the effects radiation has on vasculature could prove useful in the study of radiation effects on tissues, organs, and organisms.

  • 055028

    and

    The human body contains approximately 20 billion blood vessels, which transport nutrients, oxygen, immune cells, and signals throughout the body. The brain's vasculature includes up to 9 billion of these vessels to support cognition, motor processes, and myriad other vital functions. To model blood flowing through a vasculature, a geometric description of the vessels is required. Previously reported attempts to model vascular geometries have produced highly-detailed models. These models, however, are limited to a small fraction of the human brain, and little was known about the feasibility of computationally modeling whole-organ-sized networks. We implemented a fractal-based algorithm to construct a vasculature the size of the human brain and evaluated the algorithm's speed and memory requirements. Using high-performance computing systems, the algorithm constructed a vasculature comprising 17 billion vessels in 1960 core-hours, or 49 minutes of wall-clock time, and required less than 32 GB of memory per node. We demonstrated strong scalability that was limited mainly by input/output operations. The results of this study demonstrated, for the first time, that it is feasible to computationally model the vasculature of the whole human brain. These findings provide key insights into the computational aspects of modeling whole-organ vasculature.