Topical Review
032001
Gemma Mestres, Roman A Perez, Noelia Laura D’Elía and Laurent Barbe
The poor correlation between in vitro and in vivo studies emphasises the lack of a reliable methodology for testing the biological properties of biomaterials in the bone tissue regeneration field. Moreover, the success of clinical trials is not guaranteed even with promising results in vivo. Therefore, there is a need for a more physiologically relevant in vitro model to test the biological properties of biomaterials. Microfluidics, which is a field concerning the manipulation and control of liquids at the submillimetre scale, can use channel geometry, cell confinement and fluid flow to recreate a physiological-like environment. This technology has already proven to be a powerful tool in studying the biological response of cells in defined environments, since chemical and mechanical inputs as well as cross-talk between cells can be finely controlled. Moving a step further in complexity, biomaterials can be integrated into microfluidic systems to evaluate biomaterial-cell interactions. The biomaterial-microfluidics combination has the potential to produce more physiologically relevant models to better screen the biological interactions established between biomaterials and cells. This review is divided into two main sections. First, several possible cell-based assays for bone regeneration studies in microfluidic systems are discussed. Second, and the ultimate goal of the review, is to discuss how the gap between in vitro and in vivo studies can be shortened by bridging the biomaterials and microfluidics fields.
Paper
035001
Fumio Hashimoto, Kibo Ote, Ryosuke Ota and Tomoyuki Hasegawa
Cherenkov-based radiation detectors have been developed for time-of-flight positron emission tomography. As Cherenkov photons are emitted in an extremely short time, their use can improve time resolution. However, only up to 10 Cherenkov photons are yielded when a 511 keV gamma ray interacts with Cherenkov radiators, such as lead tungstate and lead fluoride (PbF2). Therefore, accurate estimation of the interaction position was difficult, and intense effort has been devoted to its improvement. We propose an estimation method for the 3D interaction position using a deep neural network. The network was evaluated by Monte Carlo simulations. For the simulations, a Cherenkov-based detector with a monolithic PbF2 radiator of 40 × 40 × 10 mm3 and a photodetector array were used. The gamma-ray interaction position in the radiator was estimated in 3D space by the neural network, whose inputs were the detection positions on the photodetector plane (xy plane) and timestamps of each photon from the detector. Training and validation datasets were generated while varying the single photon time resolution (SPTR) and readout pitch of the photodetector. By comparing several neural network architectures, we determined the best configuration to be the multilayer perceptron with 3 layers and 256 units. The full widths at half maximum of the xy plane and z axis (i.e., depth of interaction) were 1.54 and 1.59 mm with SPTR σ = 10 ps, respectively, and their cumulative histograms at half maximum were 0.65 and 0.81 mm also with σ = 10 ps, respectively. The proposed method retrieved higher estimation accuracy of the interaction position than an existing method based on the center of gravity and principal component analysis. Therefore, it is feasible to estimate the 3D interaction position in the Cherenkov-based detectors using deep neural networks.
035002
Dominic Maes, Rajesh Regmi, Phillip Taddei, Charles Bloch, Steven Bowen, Alexander Nevitt, Erick Leuro, Tony Wong, Anatoly Rosenfeld and Jatinder Saini
Recently, a commercial treatment planning system (TPS) has implemented aperture collimators for PBS dose calculations which can serve to reduce lateral penumbra. This study characterized the variation in magnitude of lateral penumbra for collimated and un-collimated PBS fields versus the parameters of air gap, depth, and range shifter thickness. Comparisons were performed in a homogenous geometry between measured data and calculations made by a commercial TPS. Beam-specific target volumes were generated for collimated and un-collimated PBS fields and optimized for various range shifter thicknesses and air gaps. Lateral penumbra (80%-20% distance) was measured across each target volume to characterize penumbra variation with depth and air gap. An analytic equation was introduced to predict the reduction in lateral penumbra between un-collimated and collimated PBS treatments. Calculated penumbra values increased with depth across all combinations of range shifters for a constant air gap. At 2 cm depth, the reductions in penumbra due to the aperture were 2.7 mm, 3.7 mm and 4.2 mm when using range shifter thicknesses of 0 cm, 4.0 cm and 7.5 cm, respectively. At a depth of approximately 20 cm and air gap of 5 cm, differences between penumbras of collimated and un-collimated beams were less than 1 mm. Penumbra reductions for the collimated beams were largest at small air gaps. All TPS-calculated penumbra values derived in this study were within 1 mm of film measurement values. Finally, the analytic equation was tested using a clinical CT scan, and we found good dosimetric agreement between the model predictions and the result calculated by the TPS. In conclusion, application of collimators to PBS fields can sharpen penumbra by several mm and are most beneficial for shallow targets. Furthermore, measurements indicate that the dose calculation accuracy in the penumbra region of PBS-collimated fields is adequate for clinical use.
035003
Antonio Carlos da S Senra Filho, Fabrício Henrique Simozo, Antonio Carlos dos Santos and Luiz Otavio Murta Junior
Background: Multiple Sclerosis (MS) diagnosis and evaluation is often a challenging task due to its growing need for multimodal MRI acquisition protocol. Recently, the scientific community offers several computational alternatives to the time-consuming and subjective task of manual MS lesion segmentation. Although there is an increasing number of MS lesion segmentation methods, a controlled and realistic simulation environment can benefit the community for a reliable evaluation procedure. Methods: This study proposes an automatic parametric MS lesion simulation framework (MS-MIST) with the objective to emulate real MS-like pattern on MRI data of healthy individuals. The voxel gray-level patterns, spatial location, and shapes extracted from MS patient allow consistent simulation features. We used both visual evaluation from an expert radiologist in the field of MS diagnosis and SPM Lesion Segmentation Tool (LST) for qualitative and quantitative simulation quality, respectively. Results: Our results show that both the agreement between the automatic segmentation with the simulated lesions (Pearson’s correlation R = 0.977) and the segmentation quality scores, i.e., sensitivity (mean = 0.9050), specificity (mean = 0.9992), dice similarity (mean = 0.8972), and accuracy (mean = 0.9984), are consistent between MS-MIST and real clinical settings. Conclusions: MS-MIST proposes a practical solution to common issues discussed in the literature, such as inconsistency with real lesions geometry, imprecise lesion spatial and signal variability, lack of multiple MRI modalities and restrictions to simulate different lesion loads. It is worth noting that the simulation platform is freely available as an open-source code to the community.
035004
Nassim Rafiefard, Pezhman Sasanpour, Somayeh Fardindoost and Azam Irajizad
A novel approach for particles size separation based on dielectrophoresis (DEP) method is introduced and analyzed both computationally and experimentally. The proposed technique has been utilized for the separation of polystyrene (PS) particles with 8, 6 and 2 μm diameters passing through microchannels with planar electrodes. The performance of the technique has been computationally analyzed using the finite element method (FEM). Considering the structure of the planar electrodes, we propose an approach based on applying an electric potential between one of the global electrodes, and a needle touched the top of the cell suspension. Results of both simulation and experiment show that by applying a proper voltage with 500 kHz frequency, the PS particles with 6 and 8 μm diameters will freeze in the direction of the channel while the smaller particles can pass by and exit from the outlet of the channel. Results have shown that the DEP force exerted on the particles by the middle electrode (needle) is stronger and the separation yield is higher compared with the conventional methods.
035005
David Edmunds, Greg Sharp and Brian Winey
Purpose: To automatically segment the diaphragm on individual lung cone-beam CT projection images, to enable real-time tracking of lung tumors using kilovoltage imaging. Methods: The deep neural network Mask R-CNN was trained on 3500 raw cone-beam CT projection images from 10 lung cancer patients, with the diaphragm manually segmented on each image used as a ground truth label. Ground-truth breathing traces were extracted from each patient for both diaphragm hemispheres, and apex positions were compared against the predicted output of the neural network. Ten-fold cross-validation was used to evaluate the segmentation accuracy. Results: The mean diaphragm apex prediction error was 4.4 mm. The mean percentage of projection images for which a successful prediction could me made was 87.3%. Prediction accuracy at some lateral gantry angles was worse due to overlap between diaphragm hemispheres, and the increased amount of fatty tissue. Conclusions: The neural network was able to track the diaphragm apex position successfully. This allows accurate assessment of the breathing phase, which can be used to estimate the position of the lung tumor in real time.
035006
Zikuan Chen, Qing Zhou, Yufeng Zhang and Vince Calhoun
Brain function in the resting state can be decomposed into independent spontaneous subactivities representing brain intrinsic modes. A brain task-performing activity can also be decomposed into independent modes. Previous research has shown a high spatial correspondence between the resting-state and task-present modes, but how the brain task and resting states are related remains elusive. We propose to establish a framework spanned by universal intrinsic modes (generated from a resting data analysis) to represent a brain task state through task-specific modification on a subset of intrinsic modes. We demonstrate our model and method through experimental data analysis on one group of task fMRI data and another group of rest fMRI data (from 40 different subjects). Our fingertapping experiment results show that the primary motor task only modulates a few intrinsic modes in the functional framework. The brain functional framework (spanned by universal intrinsic modes) offers a unification representation of brain task and resting states for simplifying brain functional organization
035007
Ekin Ermiş, Marcela Blatti-Moreno, Dominic Leiser, Nikola Cihoric, Daniel Schmidhalter, Dominik Henzen, Marco Malthaner, Hossein Hemmatazad, Alexandros Tsikkinis, Burim Sermaxhaj et al
Second-generation multi leaf collimator (MLC) has been introduced for the CyberKnife Robotic Radiosurgery System (Accuray Inc., Sunnyvale, USA) in 2016. The aim of the present study was to compare the plan quality between InCise 2 MLC and IRIS by analyzing dose parameters for small and large targets such as brain metastases and liver tumors, respectively. Ten brain metastases targets and 10 liver targets were selected. The following parameters were analyzed: coverage, dose distributions in planning target volume (PTV) and organs at risk (OAR), conformity index (CI), Nakamura CI (nCI), homogeneity index (HI), gradient index (GI), V12 Gy within brain, treatment time, number of beams, nodes and monitor units (MU). For brain patient group, CI and nCI were lower with IRIS plans (1.18 versus 1.26; p = 0.048 and 1.19 versus 1.28; p = 0.033, respectively), whereas GI values were higher in InCise 2 MLC plans (0.36 versus 0.33; p < 0.01). PTV mean doses were higher with IRIS plans (1.13 versus 1.16; p = 0.03). For liver tumors, InCise 2 MLC plans reached higher GI values (0.32 versus 0.29; p < 0.01). PTV minimum and mean doses were higher with IRIS plans (0.85 versus 0.93; p < 0.01 and 1.17 versus 1.2; p = 0.046, respectively). OAR’s mean dose for bowel, left-right kidney and healthy liver tissue were lower with MLC plans (0.02 versus 0.04, 0.02 versus 0.05, 0.07 versus 0.10, and 0.20 versus 0.21; p < 0.01, respectively). Shorter delivery time was reached with InCise 2 MLC for both groups (38 versus 56 min, and 42 versus 56 min; p < 0.01, for brain and liver, respectively). Results of this study showed that second generation MLC plans for intracranial and liver targets were dosimetrically feasible. The main advantages of InCise 2 MLC are the improved dose gradient and delivery time.
035008
Aaron Vance, Klaudio Bari and Arun Arjunan
In order to reduce stress shielding following a segmental bone replacement surgery requires stiffness matching strategies between the host bone and the implant are required. Carefully engineered implant geometry that can mimic the mechanical performance of the host bone is required to achieve this. The development of Additive Layer Manufacturing (ALM) techniques such as Direct Metal Laser Sintering (DMLS) allows for the fabrication of complex geometries that can achieve targeted mechanical performance. Consequently, this work introduces a sheathed Ti6Al4V additively manufactured tibial implant that mimics the circumferential anatomy of the host bone. Performance evaluation of the implant was carried using experimental and numerical technique under axial compression. Furthermore, the influence of sheathing strategy and sheath thickness on the compressive performance of the implant is parametrically analysed. The results of this study shows a promising sheathed implant that can replace a defective tibia bone segment. The implant is superior to conventional porous implants as it allows for easy implantation in surgical operation and allows for the reduction of stress shielding.
035009
The following article is Open access
Farzaneh Shalbaf, Nigel H Lovell, Socrates Dokos, Mark Trew and Ehsan Vaghefi
Purpose: Retinal prosthetic devices have been trialled in patients and encouraging results have been reported. Various factors including retinal disease state and effective electrode placement during surgery, would affect the outcome of retinal prosthesis implementation. In this study, we explore the possible effect of implant foveal eccentricity on retinal activation threshold using computational modelling. Method: Five healthy and five early stage dry age-related macular degeneration human volunteers were scanned using optical coherence tomography. The 3D retinal structure of each individual was extracted from the images and smoothly meshed. A set of five hexapolar electrode configurations was placed in the sub-foveal, 1 mm and 2 mm eccentricity positions from the centre of the retina within the subretinal space. The activation threshold for individual electrodes at all three sites of stimulation were simulated, using bidomain finite element modelling, and compared for all subjects. Results: We found that sub-foveal pit electrode placement required the lowest activation threshold, followed by the 1 mm eccentricity electrode placement. The 2 mm eccentricity electrode placement required the highest activation threshold. Conclusion: Our simulations indicate that clinically minute changes in foveal eccentricity of the subretinal implant can increase activation threshold and therefore, with a given stimulus current, retinal prosthetic performance drops with foveal eccentricity. Translational Relevance: Retinal prosthetic devices have been introduced as a potential therapy for patients suffering from outer retinal diseases. Human subjects with retinal implants demonstrated a varying range of responses to these devices. In this study, we introduce an anatomically-based patient-specific model of the human retina, using it to explore the effect of foveal eccentricity on activation threshold.
035010
A G Orlova, A V Maslennikova, G Yu Golubiatnikov, A S Suryakova, M Yu Kirillin, D A Kurakina, T I Kalganova, A B Volovetsky and I V Turchin
Modern radiation therapy of malignant tumors requires careful selection of conditions that can improve the effectiveness of the treatment. The study of the dynamics and mechanisms of tumor reoxygenation after radiation therapy makes it possible to select the regimens for optimizing the ongoing treatment. Diffuse optical spectroscopy (DOS) is among the methods used for non-invasive assessment of tissue oxygenation. In this work DOS was used for in vivo registration of changes in oxygenation level of an experimental rat tumor after single-dose irradiation at a dose of 10 Gy and investigation of their possible mechanisms. It was demonstrated that in 24 h after treatment, tumor oxygenation increases, which is mainly due to an increase in the oxygen supply to the tissues. DOS is demonstrated to be efficient for study of changes in blood flow parameters when monitoring tumor response to therapy.
035011
Yoshinori Tanabe and Takayuki Ishida
This study evaluated the feasibility of an optimized multiple acquisition planning computed tomography (MPCT) approach, along with daily cone-beam computed tomography (daily CBCT), for intensity-modulated radiotherapy (IMRT) for prostate cancer. We used MPCT to calculate the three-dimensional (3D) displacement error between the pelvic bone and a matching fiducial marker and grouped these error values by whether they were ≤1, 1–2, or ≥3 mm. The 3D displacement errors of MPCT and daily CBCT images were then compared. Correlations between the 3D displacement error values obtained for MPCT and differences between the errors of MPCT were analyzed. Furthermore, the proportions of 3D displacement error values between MPCT and daily CBCT that exceeded 1, 3, and 5 mm were compared among three groups stratified by MPCT 3D displacement error values of ≤1, 1–2, or ≥3 mm. In a correlation analysis of the 3D displacement error values of MPCT and daily CBCT, a significant difference was observed when MPCT groups with 3D displacement errors ≥3 mm were compared (p < 0.0001). The proportions of 3D displacement errors between MPCT and daily CBCT ≥ 3 mm were 13.5%, 27.6%, and 74.5% for the <1 mm, 1–2 mm, and ≥3 mm groups, respectively. Systematic errors during treatment can be attributed to the relationship between the pelvic bone and random shifts in the prostate between each planning MPCT (>3 mm) image. To avoid these errors, optimal planning CT can be estimated by selecting CT images with the smallest 3D displacement error.
035012
Yakdiel Rodríguez-Gallo, Rubén Orozco-Morales and Marlen Pérez-Díaz
Metal artifacts can impair accurate diagnosis, and degrade the image quality and diagnostic value of CT-slices. In this work we propose a novel gradient image smoothing for metal artifact reduction (GISMAR) algorithm for image quality improvement in patients with hip implants, dental fillings, DBS implants and permanent seed implants. Using Image Smoothing via L0 Gradient Minimization method, a global thresholding method, and the principle of NMAR method, the authors developed a new MAR method that does not depend on access to raw projection data. To validate the authors’ approach, 2D-CT data from twenty-two patients with different metal implants were used and processed by GISMAR and three more well- known algorithms. In order to evaluate metal artifact reduction, mean CT number (HU and SD) was calculated as well as a subjective analysis with three expert observers. Image quality on images was compared using the non-parametric Friedman-ANOVA test. We conclude that GISMAR method can efficiently reduce metal artifacts using CT-slice, does not introduce new artifacts, while preserving anatomical structures.
035013
Jyoti Thakur, Sharvan Kumar Pahuja and Roop Pahuja
Sepsis is one of the major causes of neonatal deaths worldwide. Majority of these neonatal deaths occurs in resource-poor countries due to inaccessibility of hospitals and absence of laboratories. Blood culture which is the gold standard to confirm sepsis is time-consuming and requires the presence of a laboratory. To start the antimicrobial therapy at the earliest, prediction models have been developed. A vast number of available prediction models require laboratory tests and cannot be used in the developing countries where such facilities do not exist. Therefore, there is a need for non-invasive prediction models. The objectives of this study are as follows: - (i) to train and test non-invasive prediction models for neonatal sepsis (ii) to compare the performance of the invasive with non-invasive prediction models. For this retrospective study, we extracted the data of 1446 neonates from the Medical Information Mart for Intensive Care (MIMIC) III data set. We trained and tested six prediction models using this data set. Three of these six models were trained using non-invasive parameters (model LR(NI), model ANN(NI) and model MDA(NI)) and three were trained using invasive and non-invasive parameters (model LR(O), model ANN(O) and model MDA(O)). The sensitivity of model LR(NI), model ANN(NI), model MDA(NI), model LR(O), model ANN(O) and model MDA(O) at their optimum threshold values were 81.68%, 79.39%, 82.44%, 77.10%, 79.39% and 78.63% respectively. Whereas, specificity of the above mentioned models were 82.27%, 81.82%, 80.00%, 84.77%, 82.05% and 78.30% respectively. To decrease the neonatal mortality rate in resource-poor areas one may use non-invasive prediction models where invasive parameters are not available due to lack of resources, as shown by our study that non-invasive prediction models can achieve similar predictive capability as the invasive prediction models.
035014
Jaiyam Sharma, Taisuke Ono, Ryoji Yukino, Hideki Miyashita, Naohiro Hanyu, Hiroshi Handa and Adarsh Sandhu
Fluorescent magnetic nanoparticles (f-MNPs) show potential as magnetic labels for detection of biomarkers, with their magnetic properties enhancing biomolecular interaction with external magnetic manipulation and fluorescence enabling optical detection of individual nanometer particles. These features translate into improvements in speed of detection, sensitivity, and low cost when both fluorescent and magnetic properties are utilized for biomarker detection. Specifically, f-MNPs show tremendous potential for developing smartphone based real-time diagnostic systems for monitoring potentially infectious diseases in remote areas, which is important for public healthcare to prevent epidemics, where rapid and sensitive medical diagnostic protocols designed to not only detect biomarkers but also to enable real-time information sharing are critical. We describe a new approach to biosensing by combining the advantages of magnetic and optical detection f-MNPs with the fluorescent imaging capabilities of CCD cameras of smartphones and the information sharing with cloud computing technology. Our protocol is designed to not only provide rapid sensing but also enable real-time sharing of medical diagnostics information between healthcare professionals and remote patients. As a feasibility study, we demonstrate the use of f-MNPs functionalized with prostate specific antigen (PSA) which is detected via the interactions of f-MNPs with the antibody coated silicon oxide surface. Images of ‘dry samples’ were obtained with a smartphone and analysed remotely with dedicated image processing programs on a cloud computer. Our approach enabled the detection of 100 pg ml−1 PSA in less than 60 s, which is an order of magnitude lower than the sensitivity required for clinical detection of PSA in public healthcare.
035015
Ali Ghaffari and Nasimalsadat Madani
Objective: Detection of Atrial fibrillation (AF); as a very common cardiac arrhythmia; is a challenging issue because it is often asymptotic. Most of previous studies were based on feature extraction or training CNNs from scratch. Difficulties in finding appropriate features, requiring an expertise for feature extraction and tuning parameters, and needs for a large amount of labeled data are the most drawbacks of previous studies. The transfer learning is a solution for these problems especially in the medical analysis where available data is limited. The main goal of this study is to investigate the ability of transfer learning method for classification ECG signals into normal, AF, other rhythms and noisy classes. Approach: In our analysis, ECG signals have been transformed to 6 s segments images and fed to three well-known pre-trained models (AlexNet, VGG-16, and ResNet-152). Features have been extracted from different layers of the models and used as the inputs of a classifier for AF detection. Then we have compared the best resulting model to proposed models trained from scratch. The proposed method also investigated the impact of models depth. The algorithms have been trained and validated using the public dataset of 2017 Physionet challenge. Main results: The method achieved average accuracy 87.9, and F-score 86.4 on the validation dataset (publicly available dataset). The second level of extracted features has the highest accuracy for all the pre-trained models in our study. Pre-trained AlexNet outperformed full training CNNs evaluated in this study. Significance: It is shown that the transfer learning method yields good accuracy recognition performance even when source and target datasets are completely different. The results show that the transfer learning is a reliable, accurate and low computational method to classify AF from short ECG signals while requires neither feature selection nor heavy processing steps.
035016
Yasuhiro Doi, Yoshinobu Shimohigashi, Yohei Yotsuji, Masato Maruyama, Yudai Kai and Ryo Toya
Purpose: This study evaluated the target volume (TV) definition and motion position accuracies of 4D cone-beam computed tomography (CBCT) through comparison with 4D-CT, using a dynamic thorax phantom. Methods: A dynamic thorax phantom was used to acquire 4D images with respiration motion. Targets with 20-mm diameters, motion periods of 3, 4, and 6 s, and 1D and 3D motion patterns corresponding to sin and cos6 curves were used. The TV definition was contoured on all 10 phase images via threshold segmentation on all 4D datasets. The TV union was defined as the internal target volume (ITV). The TV and ITV were compared to the theoretical TVR and ITVR. For motion position evaluation, the TV centroid positions were measured and the root mean square errors (RMSEs) of these measured positions calculated relative to the phantom setup positions. In addition, the breathing patterns of patients with lung tumor were evaluated. Results: The maximum differences in TV and ITV for 4D-CT were 0.66 cm3 and −14.03% for a cos6 motion pattern with a 3-s period, respectively. In contrast, the maximum average differences in TV and ITV for 4D-CBCT were 0.43 cm3 and −6.48%, respectively, for all motion patterns and periods. The 4D-CT and 4D-CBCT RMSEs were within 2.5 mm for most motion patterns. For patient breathing patterns, the average differences in TV, ITV, and positions between 4D-CT and 4D-CBCT were 0.18 cm3, 0.23 cm3, and 1.1 mm, respectively. Conclusions: Although 4D-CT and 4D-CBCT have differences in image acquisition and voxel size, the TV and motion position accuracies for 4D-CBCT are consistent with those of 4D-CT.
035017
Abhijeet Gorey, Paul M Jacob, Deepak T Abraham, Reetu John, Marie T Manipadam, M S Ansari, George C K Chen and Srivathsan Vasudevan
Thyroid nodule (TN), a discrete palpable swelling of the thyroid gland, is prevalent among 8% of the adult population. The important concern with these nodules is the differentiation between benign and malignant ones. Since conventional diagnostic techniques (e.g., ultrasound) are not accurate in diagnosis, clinical surgeons adopt to excision biopsy, a golden standard, which requires surgery and removal of the gland. We propose to apply Photoacoustic Spectral Response (PASR), a non-invasive and elasticity based diagnostic technique, onto TN for malignancy diagnosis. In this study, time domain photoacoustic signals were acquired through custom built experimental setup inside the surgical theatre and spectral information were obtained through signal processing. PA spectra could distinguish Follicular Variant of Papillary Thyroid Carcinoma (a thyroid cancer) from the other tissues with a high accuracy which an important challenge in conventional diagnostic techniques. Further, other tissue variants were also successfully differentiated through signal decomposition in a quantitative manner.
035018
Sadegh Mohammadi and Th Leventouri
Wavelet transformation is known as a strong method for signal and image processing tasks in the medical applications. We utilized this transformation to reduce the noise in low-dose x-ray computed tomography (CT) images. The CT images had been acquired with 75% less radiation dose compared to the normal dose scans. In this paper we propose a shrinkage function that outperforms the traditional ones and it doesn’t require any selected parameters, if it is tuned for the specific region of the patient volume. In addition, the denoising performances of combinations of wavelet orders, decomposition levels, and thresholding methods were investigated. The results revealed the best combination of wavelet order and decomposition level for low dose CT denoising.
035019
Guilherme C Parcero, José F S Costa-Júnior and João C Machado
In ultrasound elastography, the shear wave phase velocity, cs, is often used to calculate the stiffness, which can indicate whether a biological tissue has an abnormality. The shear wave phase velocity can also be used to compute shear wave dispersion, which can be related to viscosity or guided wave effects. The most common methods used for extracting the phase from waveform vibration to estimate cs are the Kalman filter (KF), the fast Fourier Transform (FFT), and the Levenberg–Marquardt Algorithm (LMA). Currently, there are no studies in the literature comparing the performance of these methods; hence, this study aims to show the error in estimating the phase velocity obtained with the mentioned methods and to compare them through computational simulations and experiments. In the computational simulations, the absolute value of mean and the standard deviation of relative error of cs were evaluated as a function of signal-to-noise ratio, number of cycles of the shear wave, pulse repetition frequency, and initial phase. The experimental setup used an ultrasonic benchtop system, with a 2.104-MHz frequency transducer, TV, to generate acoustic radiation force at a plastic sphere and consequently induce shear wave propagation in a 7% gelatin phantom. Another ultrasonic benchtop system, with a 4.89-MHz frequency transducer, was used on pulse-echo mode to monitor the shear wave propagation at different positions within the phantom. The computational simulation results demonstrated that LMA and KF demonstrated the best performance in extracting the phase employed to estimate the shear wave phase velocity. In some situations, the cs values obtained by means of KF, FFT, and LMA methods in the experimental results presented a statistical difference, but the highest differences between the mean of cs was smaller than 0.03 m s−1.
035020
Patrick C Bonasso, Kevin W Sexton, Steven C Mehl, Michael S Golinko, Md Abul Hayat, Jingxian Wu, Morten O Jensen, Samuel D Smith, Jeffrey M Burford and Melvin S Dassinger
Objectives: The purpose is to describe our institution’s experience with collecting peripheral venous pressure (PVP) waveforms using a standard peripheral intravenous catheter in a pediatric patient under general anesthesia. Approach: PVP waveforms, piezoelectric monitoring, arterial blood pressure recording, and electrocardiogram (EKG) tracings were collected from patients undergoing cranial vault reconstruction for craniosynostosis. Data was obtained prospectively in a continuous manner from time of patient final positioning to closure of incision. Description of the technical aspects are discussed. Main Results: The waveform data collection was affected by the following: use of electrocautery, location of electrocautery in relation to PVP monitor, and movement of the operating room table. Significance: PVP waveforms can be collected in a pediatric patient undergoing general anesthesia with accurate data acquisition. Additionally, the set-up used also allows for accurate collecting of piezoelectric monitoring, arterial blood pressure recording, and EKG tracings in real time.
035021
Muhammad Sufyan, Muzamil Hussain, Hassaan Ahmad, Naseem Abbas, Jawaria Ashraf and Nida Zahra
Ultra-High Molecular Weight Polyethylene (UHMWPE) is an engineering polymer used as a bearing material with metallic or ceramics counter surfaces in orthopedic implants because of its high ductility, compatibility and impact resistance. Several methods, including cross-linking, surface texturing and particle or fiber reinforcement have been employed to improve the tribological performance of UHMWPE. In this study, square and rectangular bulge textures were introduced on UHMWPE and their influence on friction and wear properties under Phosphatidylcholine (Lipid) and Bovine Serum Albumin (BSA) solutions were investigated. The laser texturing was performed under different conditions such as using distilled water layer, aluminum foil and at freezing and room temperature with varying laser processing parameters including scanning speed, pulse frequency, and laser intensity. The textures in the required dimension were produced using only aluminum foil by controlling melt viscosity. The ball-on-disk tribometer was used for tribological tests. The reduction in coefficient of friction (COF) was recorded in case of textured specimens as compared to un-textured specimens at low concentration of BSA and at higher concentration of lipid. However for both cases, the square texturing was proved optimal as compared to rectangular texturing because of the higher area ratio of square textures.
035022
D A Pollacco, L Farrugia, M Caligari Conti, L Farina, P Schembri Wismayer and C V Sammut
The aim of this study was to characterize the hydration fractions of biological tissues and to model these accurately from mixture equations. Hydration fractions, better known as volume fractions, are based on quantification of tissue hydration and accurate knowledge about the physiological composition of tissue fluids. Data on weight loss percentages for excised muscle and adipose tissue from a previous study were utilized for this purpose. The Bruggeman and Maxwell Garnett equations were then used to characterize the dielectric properties of the tissues in terms of mixtures of dry biological constituents and physiological saline solutions. It is shown that these models are accurate in modelling in vivo and ex vivo tissue in different states of hydration. This is based on precise knowledge of the physiological composition of biological fluids and their corresponding percentage contents.
035023
Toygun Başaklar, Yiğit Tuncel and Yusuf Ziya Ider
Objective: This study aims at investigating the effects of high stimulus presentation rates on the characteristics of c-VEP responses along with the change in performance depending on the stimulus presentation rate by utilizing a c-VEP based speller BCI. Approach: Twenty subjects participated in three different experiments with refresh rates of 60 Hz (E1), 120 Hz (E2) and 240 Hz (E3), where a 127-bit m-sequence is used. To observe the change in frequency content of c-VEP responses, PSD estimates of c-VEP responses were evaluated. Principal component analysis (PCA) was applied to observe how many distinguishable responses could be evoked with a 127-bit length m-sequence for three different refresh rates. Main Results: Average ITR and accuracy values are 85.87 bits min−1 and 92% for E1, 94.21 bits min−1 and 97% for E2, and 78.65 bits min−1 and 87% for E3 respectively. The c-VEP responses are band-limited although the bandwidth of the input signal significantly increases as the refresh rate increases. The spectral densities of c-VEP templates are concentrated on several frequency intervals, especially for E3, which eventually results in a target misclassification. PCA shows that the number of well distinguishable responses decreases with the increasing refresh rate. Considering all results and observations, we suggest that 120 Hz refresh rate is best to use in BCIs with high number of targets whereas 240 Hz refresh rate may be prefered for low number of targets. Significance: This study mainly investigates the alterations in the characteristics of c-VEP responses according to the stimulus presentation rate which have never been investigated thoroughly before. Our results show that increasing refresh rate does not necessarily increase the overall performance of the system due to the changes in characteristics of c-VEP responses. Further applications and designs of a c-VEP based BCIs will benefit from the observations and results of this study.
035024
Seiichi Yamamoto, Kouhei Nakanishi, Takako Furukawa and Hideki Tomita
The in-vivo imaging of C-14 is thought to be impossible because it is a pure beta-emitting radionuclide and the energy of beta particles is low. However, beta particles emit bremsstrahlung x-rays in subjects that may be imaged from the outside subjects. Thus, we imaged bremsstrahlung x-rays from a C-14 solution using a high resolution Ce-doped (Gd, La)2Si2O7 (LaGPS) radiation imaging system. With a LaGPS radiation imaging system, we conducted bremsstrahlung x-ray imaging from a C-14 solution in a plastic container with 37 MBq radioactivity with and without a parallel hole collimator. Without it, images were obtained with a spatial resolution of ∼1 mm FWHM in less than 1 min of acquisition time. The energy spectrum of the bremsstrahlung x-rays from a C-14 solution showed a broad distribution with an average energy of ∼30 keV. With a parallel hole collimator, images of the C-14 solutions were also possible although the detected counts decreased to 2.4% of those without a collimator. The measured sensitivities of the LaGPS imaging system without and with a collimator for bremsstrahlung x-rays from C-14 solutions in a plastic container were 3.5 × 10−5 and 8.5 × 10−7, respectively. We conclude that the imaging of bremsstrahlung x-rays from C-14 might be a new method for the in-vivo distribution imaging of small animals or plants.
035025
Mario Sansone, Roberta Fusco and Antonella Petrillo
The aim of this paper is to optimally design the set of b-values for diffusion weighted MRI with the aim of precise estimation of intra-voxel incoherent motion (IVIM) parameters (f perfusion fraction, Ds slow diffusion, Df fast diffusion) according to the model developed by Le Bihan. Previous studies have addressed the design in a Monte Carlo fashion; however, due to huge computation times, this approach is practical only for a limited number of values of the parameters (local design): however, as the parameters of a specific patient are not known a priori, it would be desirable to optimise b-values over a region of parameters. In order to address this issue, we propose to use a D-optimal design approach. Our study has two key results: first, under fairy general conditions, the optimal design does not depend on perfusion fraction: this allow to perform a search over a 2D parameter space instead of 3D; second, as an exhaustive search over all possible designs would still be time consuming, we proposed an algorithm to find an approximate solution very quickly.
035026
Elodie Lugez, Hossein Sadjadi, Chandra P Joshi, Keyvan Hashtrudi-Zaad, Selim G Akl and Gabor Fichtinger
Purpose: Electromagnetic (EM) tracking of ultrasound (US) probes has been introduced to expand US imaging capabilities and benefit challenging procedures. However, various instruments—including the US probe itself—may introduce dynamic distortions to the EM field, and compromise the EM measurements. Basic filtering methods, such as those provided by manufacturers, are usually inefficient as they do not allow for field distortion compensation. We propose to use a simultaneous localization and mapping (SLAM) algorithm to track the transrectal US (TRUS) probe while dynamically detect, map, and correct the EM field distortions. Methods: Combining the motion model of the tracked probe, the observations made by a few redundant EM sensors, and the field distortions map, the SLAM algorithm relied on an extended Kalman filter (EKF) to estimate the tracking measurements. The SLAM technique was experimentally validated in a brachytherapy suite. Tracking of a TRUS probe was performed by means of an Ascension trakSTAR tracking system and four EM sensors. In addition, an optical tracking system was employed to provide a ground truth to our data. The performance of the SLAM technique was analysed by varying pertinent parameters, such as the number of redundant measurements and the motion trajectory. Probe trajectories included longitudinal translation, rotation, and freehand motions (consisting of simultaneous longitudinal translation and rotation motions) in order to comprehensively simulate imaging scenarios. Finally, the accuracy of the SLAM estimations was compared with that of the standard filtering methods provided by the manufacturer, as well as that of a simpler sensor fusion technique. Results: SLAM efficiently reduced position tracking errors up to 46.4% during freehand motions of the TRUS probe. Moreover, higher SLAM estimation accuracies were observed as the number of redundant measurements increased. While both TRUS probe motions did not yield a clinically significant trend on position tracking accuracy, orientation measurements were considerably improved during translation of the TRUS probe. Conclusions: The SLAM technique was effective in increasing the tracking accuracy of the TRUS probe. Higher number of redundant sensors and favorable sensor configurations improved the SLAM estimations of EM measurements. In turn, SLAM can further encourage the introduction of EM tracking assistance in clinical procedures such as prostate brachytherapy.
035027
Craig S Moore, Tim J Wood, Steven Jones, John R Saunderson and Andrew W Beavis
We have established in recent virtual clinical trials that signal-to-noise ratio (SNR) is the most appropriate metric for calibrating AEC devices used with digital imaging systems for chest, abdomen, pelvis and spine radiography. However, the practical calibration of such devices is not straightforward. The purpose of this study was to expand on previous work by developing a practical method for AEC calibration using the validated SNR metric that may be used by medical physicists in the field for phosphor plate radiography (CR) and direct digital radiography (DR - wireless and integrated) imaging systems. This methodology used a uniform tissue equivalent phantom (Poly-methyl methacrylate (PMMA)) so comparison was made with an installation vendor’s method of using copper plates. System transfer properties (STP) of each system were derived to linearise all images required for analyses. All STP correction was done in real time. The relationship between detector air kerma (DAK) and STP corrected SNR was then derived at four tube voltages (60, 80, 100 and 120 kVp) and using this relationship, together with the target value of the calibration metric (SNRtarget), it was possible to calculate the DAK required at each tube voltage to derive a calibration curve for each system; CR systems exhibited a linear increase with kVp, DR systems exhibited a ‘U’ shape. The curve derived using the vendor’s method was not considered optimised because it did not hold SNR constant. This work has demonstrated that a relatively simple method to calibrate AEC devices, using an easily accessible tissue equivalent phantom, can be used in the field in real time by medical physicists working with installation engineers. AEC calibration curves that produce clinically adequate image quality with acceptable patient dose have been installed in our radiology department for CR and DR systems using the methodology described in this paper.
035028
Olivia M Giza, Daniel Sánchez-Parcerisa, Víctor Sánchez-Tembleque, Joaquin L Herraiz, Jorge Camacho, Stephen Avery and José Manuel Udías
This work describes all stages of development (setup, optimization, performance, and first experimental measurements) of an acoustic sensor that can be used for range monitoring and dosimetry of clinical radiotherapy beams. The detection device consists of an ultrasonic transducer, a combination of preamplifiers and differential amplifiers with filtered outputs and a digital oscilloscope. Simulations of the experimental setup were carried out to study the optimal measurement geometry and choice of transducer. The dose distributions were calculated with the Monte Carlo code FLUKA, while the acoustic simulations were performed with the analytical wave transport code k-Wave. The temporal profiles of the dose pulses, in the order of μs, were measured with a scintillating crystal coupled to a photomultiplier and used as input for the acoustic simulation. Measurements were performed in a Cyberknife™ radiosurgery beam and a TrueBeam unit. A lead block was submerged in water and placed partially or totally in the irradiation field in order to increase the acoustic signal. Photoacoustic signals were detected with both beams with the expected shape and time-delay, after the frequency response of the detection system was taken into account. The proposed setup can detect photoacoustic signals originating from the penumbra of the treatment fields after being processed with the appropriate image analysis tools.
035029
Maryam Ali and Jason B Shear
Development of materials that can dynamically alter the topographic experience of cultured cells is key to accurately modeling in vivo processes such as tissue development and repair. Current technologies have largely focused on smart substrate materials that can be programmed to undergo topographical transformations in the presence of adhered cells, but such materials provide limited spatiotemporal resolution and generally are triggered by undesirable changes to environmental conditions. Here, we present an approach for investigating cellular responses to dynamic topographical cues in which multiphoton photochemistry is used to remotely imprint a substrate with arbitrary topographical patterns in real time (i.e., in the presence of adherent cells). In these studies, fibroblastic NIH3T3 cells were plated on a planar protein hydrogel substrate, where they generally established stereotypical polygonal morphology before the underlying substrate was dynamically transformed to a grooved topography. Elongation and alignment of cells exposed to low-micrometer-pitch grooves imprinted in this manner occurred less rapidly than for cells directly deposited on substrates having pre-formed grooves. Further, cell alignment on dynamically imprinted grooves was notably delayed relative to elongation, suggesting that the structural attributes of a cell at the time it first experiences a grooved topography may differentially influence these two processes. This minimally invasive approach for subjecting cells to dynamic topographical experiences represents a versatile means to model evolving conditions within in vivo systems and to systematically explore mechanisms of cellular morphology and behavior.
035030
N H Meshram, C C Mitchell, S M Wilbrand, R J Dempsey and T Varghese
Carotid plaque rupture can result in stroke or transient ischemic attack that can be devastating for patients. Ultrasound strain imaging provides a noninvasive method to identify unstable plaque likely to rupture. Axial, lateral and shear strains in carotid plaque have been shown to be linked to carotid plaque instability. Recently, there has been interest in using principal strains, which do not depend on angle of insonification of the carotid artery for quantifying instability in plaque along the longitudinal view. In this work relationships between angle dependent axial, lateral and shear strain along with axis independent principal strains are compared. Three strain indices were defined, (1) Average Mean Strain (AMS), (2) Maximum Mean Strain (MMS) and (3) Mean Standard Deviation (MSD) to identify relationships between these five strain image types in a group of 76 in vivo patients. The maximum principal strain demonstrated the highest strain values when compared to axial strain for all patients with a linear regression slope of 1.6 and a y intercept of 2.4 percent strain for AMS. The maximum shear strain when compared to shear strain had a slope of 1.15 and a y intercept of 0.21 percent for AMS. Next, the effect of insonification angle, which is the angle subtended by the artery at the location of plaque was studied. Patients were divided into three sub groups, i.e. less than 5 degrees (n = 31), between 5 and 10 degrees (n = 24) and above 10 degrees (n = 21). The angle of insonification did not make a significant difference between the three angle groups when comparing the relationship between the angle dependent and independent strain values.
035031
R Zerafa, T Camilleri, K P Camilleri and O Falzon
Objective. This study analyses the effect of distractors on steady-state visually evoked potentials (SSVEP) to establish how these nuisance signals, typically present in the real-world, would effect an SSVEP-based brain-computer interface (BCI). The distractors introduced to the SSVEP-based experiments are auditory, visual and movement distractors, specifically selected to reflect the use of various BCIs outside the laboratory. Approach. An assessment on the influence of these nuisance signals on SSVEP data as compared to SSVEP data with no distractors is presented. This is done by examining the frequency spectrum of the SSVEP responses followed by the implementation of feature extraction techniques, specifically canonical correlation analysis (CCA) and power spectral density analysis (PSDA), and a statistical analysis on the results obtained. As an added contribution, this study is designed to have each subject repeat the same experiments on different days such that the variation in performance with and without distractors may be investigated longitudinally. Main results. The results revealed that the spectra and the classification performance of the auditory distractors condition are comparable with the no distractors condition. On the other hand, there is a decrease in the signal-to-noise ratios (SNRs) of the visual and movement distractors conditions. This is reflected with a significant decrease in the SSVEP performance of 4.29% and 12.14% for the two distractor conditions respectively compared to the no distractors condition. A significant above-chance level SSVEP performance could still be obtained with all the distractor conditions. The longitudinal analysis revealed that the difference in performance between the SSVEP experimental conditions was consistent across sessions. Significance. This study provides a comparison on the performance of an SSVEP-based BCI with various external distractors. This analysis is necessary for the transition of BCI applications to be used every day in uncontrolled environments.
035032
Pejman Shojaee and Hanieh Niroomand-Oscuii
Today, one of the biggest challenges for the physicians and scientists is optimizing the drug transport to the solid tumors. Predicting the behavior of the formation of the vasculature in tumor and normal tissues is the hallmark for the drug delivery to the cancerous cells. In this study, we assume a geometry with microvessels in tumor and its surrounding tissue. We employed Darcy’s law and starling’s law to obtain the steady-state interstitial fluid pressure and velocity. Then, these values are used for the transient drug transport equation. Our aim is to investigate the drug transport in a vascularized medium by considering the plasma concentration as a variable. Our results show that the high interstitial fluid pressure and heterogeneity of tumor’s vasculature are the main barriers to drug penetration and cell killing. In this study, we used a denser network of microvasculature in both tumor and normal tissues. Different doses and time periods for the drug administration are also investigated under the tri-exponential plasma concentration. Interstitial drug concentration is highly depended on the pressure gradient. The convection term is negligible in comparing with diffusion owing to the low interstitial fluid velocity. Two methods of drug injection are compared that both suffered from the low convection rate through the cancerous tissue. The elimination rate of the drug is shown based on the different amount of dosages.
035033
Emilie Roncali, Sun Il Kwon, Sebastien Jan, Eric Berg and Simon R Cherry
Purpose: We are investigating the use of promptly emitted Cerenkov photons to improve scintillation detector timing resolution for time-of-flight (TOF) positron emission tomography (PET). Bismuth germanate (BGO) scintillator was used in most commercial PET scanners until the emergence of lutetium oxyorthosilicate, which allowed for TOF PET by triggering on the fast and bright scintillation signal. Yet BGO is also a candidate to generate fast timing triggers based on Cerenkov light produced in the first few picoseconds following a gamma interaction. Triggering on the Cerenkov light produces excellent timing resolution in BGO but is complicated by the very low number of photons produced. A better understanding of the transport and collection of Cerenkov photons is needed to optimize their use for effective triggering of the detectors. Methods: We simultaneously generated and tracked Cerenkov and scintillation photons with a new model of light transport that we have released in GATE V8.0. This crystal reflectance model was used to study photon detection and timing properties, building realistic waveforms as measured with silicon photomultipliers. Results: We compared the behavior and effect of detecting Cerenkov and scintillation photons at several levels, including detection time stamps, travel time, and coincidence resolving time in 3 × 3 × 20 mm3 BGO crystals. Simulations showed excellent agreement with experimental results and indicated that Cerenkov photons constitute the majority of the signal rising edge. They are therefore critical to provide early triggering and improved the coincidence timing resolution by 50%. Potential applications: To our knowledge, this is the first complete simulation of the generation, transport, and detection of the combination of Cerenkov and scintillation photons for TOF detectors. This simulation framework will allow for quantitative study of the factors influencing timing resolution, including the photodetector characteristics, and ultimately aid the development of BGO and other Cerenkov-based detectors for TOF PET.
035034
Fulya Ersoy and Emel Sokullu
Tissue engineers seek for the practical and affordable fabrication methods to be able to create the best biomimicking scaffold. The aim of the study was to create an easy-to use device to fabricate precisely designed 3D hydrogel scaffolds for co-culturing, tri-culturing and multi-culturing practices. In this study, gelatin methacryloyl (GelMA) was synthesized and textured three-dimensional hydrogel scaffolds were fabricated via photopolymerization using compartmental fabrication device. This device allowed fabricating computer aided designed (CAD) geometries precisely and encapsulating different cells in different hydrogel posts while building a whole geometry. The hydrogel texture characterization was performed using colored hydrogel solutions and it is observed that the device keep the distinct posts in contact precisely. A neural tissue model was created using neural, epithelial and endothelial cells as a proof of concept. Cell distribution was evaluated using cell trackers. The viability and the proliferation assays were also performed and the viability was above 80% while a positive proliferation was been observing. Overall findings showed that this device offers a practical way to fabricate and align precisely designed three-dimensional hydrogel scaffolds which allows modelling various types of tissues and organs and it tis promising for further applications in many fields.
035035
Youngung Seok, Hyungjun Jang, Jusung Oh, Hyou-Arm Joung and Min-Gon Kim
Deoxyribonucleic acid (DNA) extraction procedure is commonly based on well-developed and commercialized silica-based techniques. However, there are limits to utilize in resource-limited environments due to being time-consuming, labor-intensive, and expensive. Although simple DNA extraction systems have been recently reported, there are still remaining challenges for conventional treatment to complex samples such as blood, food, and soil. Here, we demonstrated a handheld lateral flow strip for rapid DNA extraction from complex samples. We designed the lateral flow system based on investigation of basic property for DNA binding and proper arrangements of various materials. Engineering structure of the lateral flow strip made by the arrangement of convenient pad materials is playing a key role for DNA extraction device without expensive fabrication technique. Different binding affinity to DNA molecules of pad materials is inducing DNA transportation and concentration on the elution hole by lateral flow separation. Result of rapid DNA extraction by the handheld strip was shown similar efficiency to a commercialized silica column. In the concentration between 10 CFU to 106 CFU, and the volume of 5 μl to 100 μl, DNA extraction from Staphylococcus aureus cells in buffer was successfully performed by the handheld strip. We successfully showed that the rapid and effective DNA extraction in various type of complex samples (such as saliva, whole blood, urine, milk, meat, soil, and pond water) can be performed using the handheld strip within 3 min. Moreover, this fabricated strip could be an excellent platform for DNA storage and transportation, thus being potentially suitable for expanding the area of DNA analysis in resource-limited environments.
035036
Anubha Kalra, Andrew Lowe and Ahmed Al-Jumaily
This article focusses on preparation and mechanical testing of thin-polymer electrodes to efficiently measure the biomedical signals while providing a conformal skin-contact. The method to prepare thin electrode films using Polydimethylsiloxane (PDMS) with different Young’s moduli has been described. The Young’s modulus was evaluated for each film by conducting tension-relaxation tests. The PDMS electrodes were made conductive by mixing them with Multi-Walled Carbon Nano Tubes (MWCNTs) and Graphene Nano Powder (GNP) using an ultrasonic mixer. The current study addresses a novel approach of preparing PDMS based sensors by doping them with CNTs and GNPs and wetting them in N-N Dimethylformamide (DMF) prior to their dispersion in PDMS. This was done to avoid their clumping in PDMS and to ensure more uniform dispersion. The conductance of the PDMS/MWCNT and PDMS/GNP electrodes were measured using an impedance spectrometer and were compared with that of standard silver-silver chloride (Ag/AgCl) and dry silver (Ag) electrodes.
Note
037001
Gengsheng L Zeng
Green’s one-step-late (OSL) algorithm is a popular image reconstruction algorithm in emission-data tomography, in spite of its convergence issues. One drawback of Green’s algorithm is that the algorithm exhibits non-stationary regularization when the algorithm’s projector and backprojector model the attenuation effects in single photon emission computed tomography (SPECT). This paper suggests a remedy to improve Green’s OSL algorithm so that stationary regularization can be obtained. This paper also observes some similarities between the modified Green’s OSL algorithm and the gradient descent algorithm.
037002
Mechelli Filippo, Arendt-Nielsen Lars, Stokes Maria and Agyapong-Badu Sandra
Objective: To determine intra-rater and inter-rater reliability of ultrasound imaging for measuring muscle and non-contractile (subcutaneous fat and perimuscular fascia) tissue thickness of the anterior thigh. Approach: Ultrasound imaging has been used for clinical research to assess the morphology and cross-sectional area of muscles and other musculoskeletal structures. Repeatability of measurements with the ultrasound imaging technique between operators and test re-test reliability are important and need to be established for specific muscles. Twenty-four healthy moderately active adults (aged 36–64 years), underwent B-mode ultrasound imaging by two investigators. The anterior thighs were scanned at a site two-thirds of the distance between the antero-superior iliac spine and the superior pole of the patella. Intraclass Correlation Coefficients (ICCs, model 3, 1 for inter-rater and 3, 2 for intra-rater reliability between-days) with 95% confidence intervals (CI) was used to assess reliability. Main results: Inter-rater reliability of ultrasound imaging measurements were ICC3, 1 of 0.98 (95% CI: 0.95–0.99) for muscle thickness, 0.81 (95% CI: 0.60–0.91) for subcutaneous fat, 0.78 (95% CI: 0.56–0.90) for non-contractile tissue (subcutaneous fat combined with perimuscular fascia), and 0.70 (95% CI: 0.42–0.86) for perimuscular fascia. Intra-rater reliability values were ICC3, 2 0.96 (95% CI: 0.90–0.98) for muscle thickness, 0.99 (95% CI: 0.97–0.99) for subcutaneous fat, 0.98 (95% CI: 0.96–0.99) for non-contractile tissue, and −0.02 (95% CI: −0.41–0.38) for perimuscular fascia. Significance: The present findings indicate very high inter-rater and intra-rater reliability of ultrasound imaging thickness measurements of the quadriceps muscles and non-contractile tissue of the anterior thigh, while perimuscular fascia measurements alone were not reliable between days.
037003
Benjamin Lewis, Robert Cadrain, Emma Fields, Siyong Kim and Taeho Kim
Purpose:Motion must be accounted for with focal treatments such as liver directed stereotactic body radiotherapy otherwise there is a risk of marginal miss and/or increased toxicity to surrounding structure. There have been many proposed methods for motion management including respiratory gating, inhibition and tracking. The purpose of this study is to evaluate a pressure-based respiratory motion management system with biofeedback to the patient for MR-guided radiotherapy treatments. Methods:A respiratory motion management belt was modified in house to provide visual biofeedback of subject respiratory trace using pressure readings from an air bladder. Three groups participated in the study: Group I included two investigators who were imaged twice, with imaging sessions separated by one week, while wearing the motion management belt. Group II included four healthy volunteers, imaged using the belt for CINE and anatomical imaging. Group III included two cancer patients with liver lesions imaged while wearing the device, imaged pre-radiotherapy treatment, and post-treatment. During image acquisition, a display showed participants their respiratory traces and guidelines to indicate the desired respiratory amplitude. Results:The average peak-to-peak motion of the liver dome was decreased from 30.55 ± 7.83 mm to 5.58 ± 0.85 mm for free-breathing and utilizing a small window guiding box with visual guidance CINE image sets respectively in the investigator study. Volunteers and cancer patients were able to consistently manage their breath traces, including sequential breath holds, over the course of 30–60 min imaging sessions. Conclusions: The proposed motion management belt with visual biofeedback design is able to provide greatly reduced respiratory motion of the liver, and repeatable breath hold in MR simulation. The components used in the device also allow it to be in place during all steps of the radiotherapy planning process, including MR anatomical imaging, CT simulation, and treatment delivery due to the absence of high z or metallic material.