Papers
P06023
J. Ashenfelter, A.B. Balantekin, H.R. Band, C.D. Bass, D.E. Bergeron, D. Berish, N.S. Bowden, J.P. Brodsky, C.D. Bryan, A. Bykadorova Telles et al
This paper describes the design and performance of a 50 liter, two-segment 6Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the 6Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850±20 PE/MeV, an energy resolution of σ = 4.0±0.2% at 1 MeV, and efficient pulse-shape discrimination of low dE/dx (electronic recoil) and high dE/dx (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85±3 cm is measured in each segment. The 0.1% by mass concentration of 6Li in the scintillator results in a measured neutron capture time of τ = 42.8±0.2 μs. The long-term stability of the scintillator is also discussed. The detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.
P06022
The following article is Open access
D.L. Adams, T. Alion, J.T. Anderson, L. Bagby, M. Baird, G. Barr, N. Barros, K. Biery, A. Blake, E. Blaufuss et al
The 35-ton prototype for the Deep Underground Neutrino Experiment far detector was a single-phase liquid argon time projection chamber with an integrated photon detector system, all situated inside a membrane cryostat. The detector took cosmic-ray data for six weeks during the period of February 1, 2016 to March 12, 2016. The performance of the photon detection system was checked with these data. An installed photon detector was demonstrated to measure the arrival times of cosmic-ray muons with a resolution better than 32 ns, limited by the timing of the trigger system. A measurement of the timing resolution using closely-spaced calibration pulses yielded a resolution of 15 ns for pulses at a level of 6 photo-electrons. Scintillation light from cosmic-ray muons was observed to be attenuated with increasing distance with a characteristic length of 155 ± 28 cm.
P06021
S. Kasaei, Sh. Sanaye Hajari, M. Bahrami and H. Shaker
A spectrometer design has been presented for the electron linear accelerator at Institute for Research in Fundamental Sciences (IPM), Tehran, Iran. The energy of the linac is 8 MeV (upgradable to 11 MeV) with a maximum current of 10 mA. The design and construction of the machine is nearly finished and it is in the commissioning stage. The linac consists of a thermionic electron gun followed by a pre-buncher and some travelling wave tubes connected together via appropriate flanges. The commissioning process is foreseen in stages of different energies. At each stage an RF cavity will be appended in order to investigate its performance. Therefore, the energy diagnostics is demanded in a wide range—from 50 keV to 8 MeV . A spectrometer based on a dipole magnet, a movable view screen and a focusing solenoid is proposed for this purpose. The challenge is to keep the resolution in the wide range of measurements. This paper first describes the beam dynamics design of the spectrometer with the focus on the measurement resolution. Then the magnetic design of the dipole is presented in details. Two and three dimensional simulations have been carried out in order to optimize the dipole parameters such as the magnetic flux density, multipole components, and the integrated field quality. Finally, magnetic design features of the solenoid have been discussed.
P06020
A.A. Ibrahim, M.A. Abdalla and W.A.E. Ali
Band stop/pass filters using octagonal and rectangular-shaped open loop resonators are proposed for wireless applications. The filter has the advantage of low insertion loss in the passbands and high return loss in the stopbands. The main idea of the filter is to achieve transmission bands by utilizing rectangular shape open loop resonators which are coupled to the input and output ports. The open loop resonators are used to generate stopbands in the filter response. The filter has small size, good response and the simulated results agree with the measured results. The lower insertion loss, and higher rejection band levels are investigated which confirm the suitability of the proposed dual BPF for WLAN and WiMAX applications.
P06019
The following article is Open access
R. de Olivera and M. Cortesi
We describe a new micro-pattern gas detector structure comprising a multi-layer hole-type multiplier (M-THGEM) combined with two in-built electrode meshes: the Multi-Mesh THGEM-type multiplier (MM-THGEM). Suitable potential differences applied between the various electrodes provide an efficient collection of ionization electrons within the MM-THGEM holes and a large charge avalanche multiplication between the meshes. Different from conventional hole-type multipliers (e.g. Gas Electron Multipliers - GEMs, Thick Gas Electron Multipliers—THGEMs, etc.), which are characterized by a variable (dipole-like) field strength inside the avalanche gap, electrons in MM-THGEMs are largely multiplied by a strong uniform field established between the two meshes, like in the parallel-plate avalanche geometry. The presence of the two meshes within the holes allows for the trapping of a large fraction of the positive ions that stream back to the drift region. A gas gain above 105 has been achieved for single photo-electron detection with a single MM-THGEM in Ar/(10%)CH4 and He/(10%)CO2, at standard conditions for temperature and pressure. When the MM-THGEM is coupled to a conventional THGEM and used as first cascade element, the maximum achievable gains reach values above 106 in He/(10%)CO2, while the IBF approaches of 1.5% in the case of optimum detector-bias configuration. This IBF value is several times lower compared to the one obtained by a double GEM/THGEM detector (5–10%), and equivalent to the performance attained by a Micromegas detector.
P06018
A.M. Baldini, E. Baracchini, G. Cavoto, F. Cei, M. Chiappini, G. Chiarello, C. Chiri, M. Francesconi, L. Galli, F. Grancagnolo et al
The reconstruction of the positron trajectory in the MEG II experiment searching for the μ+ → e+ γ decay uses a cylindrical drift chamber operated with a helium-isobutane gas mixture. A stable performance of the detector in terms of its electron drift properties, avalanche multiplication, and with a gas mixture of controlled composition and purity has to be provided and continuously monitored. In this paper we describe the strategies adopted to meet the requirements imposed by the target sensitivity of MEG II, including the construction and commissioning of a small chamber for an online monitoring of the gas quality.
P06017
The following article is Open access
C. Allaire, J. Benitez, M. Bomben, G. Calderini, M. Carulla, E. Cavallaro, A. Falou, D. Flores, P. Freeman, Z. Galloway et al
For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at |z|= 3.5 m and covering the region 2.4 <|η|< 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 μm thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sensors with a surface area of 1.3×1.3 mm2 and arrays with 2×2 pads with a surface area of 2×2 mm2 or 3×3 mm2 each and different implant doses of the p+ multiplication layer. They are obtained from data collected during a beam test campaign in autumn 2016 with a pion beam of 120 GeV energy at the CERN SPS. In addition to several quantities measured inclusively for each pad, the gain, efficiency and time resolution have been estimated as a function of the position of the incident particle inside the pad by using a beam telescope with a position resolution of few μm. Different methods to measure the time resolution are compared, yielding consistent results. The sensors with a surface area of 1.3×1.3 mm2 have a time resolution of about 40 ps for a gain of 20 and of about 27 ps for a gain of 50 and fulfil the HGTD requirements. Larger sensors have, as expected, a degraded time resolution. All sensors show very good efficiency and time resolution uniformity.
P06016
P. Lyu, D. Han, Y. Wang, B. Guo, F. Wang, X. Chen, Y. Yu, Y. Li, L. Naumann, A. Lazo Garcia et al
Towards the future CMS RPC upgrade, a real-size mosaic high-rate MRPC has been designed and developed by Tsinghua University. The prototype is a 5-gap counter composed of the low-resistive glass. Because the maximum size of this glass cannot exceed 330 × 280 mm2, 6 regions of glass stacks are mosaicked together in order to achieve a large active area. This prototype was tested in HZDR-ELBE with 30 MeV e-beam. It shows an efficiency above 95% at the rate of 2 kHz/cm2. The time resolution is around 55 ps, and the cluster size is below 1.5. The performance is almost unaffected by increasing the rate to 11 kHz/cm2. This design is proved to be fully capable of the CMS upgrade requirement by this HZDR beam test. The mosaic technology will make the high-rate MRPC a good choice in large-area timing systems.
P06015
The following article is Open access
A.M. Sirunyan, A. Tumasyan, W. Adam, F. Ambrogi, E. Asilar, T. Bergauer, J. Brandstetter, E. Brondolin, M. Dragicevic, J. Erö et al
The CMS muon detector system, muon reconstruction software, and high-level trigger underwent significant changes in 2013–2014 in preparation for running at higher LHC collision energy and instantaneous luminosity. The performance of the modified system is studied using proton-proton collision data at center-of-mass energy √s=13 TeV, collected at the LHC in 2015 and 2016. The measured performance parameters, including spatial resolution, efficiency, and timing, are found to meet all design specifications and are well reproduced by simulation. Despite the more challenging running conditions, the modified muon system is found to perform as well as, and in many aspects better than, previously. We dedicate this paper to the memory of Prof. Alberto Benvenuti, whose work was fundamental for the CMS muon detector.
P06014
B.K. Ofori-Okai, M.C. Hoffmann, A.H. Reid, S. Edstrom, R.K. Jobe, R.K. Li, E.M. Mannebach, S.J. Park, W. Polzin, X. Shen et al
We describe a new experimental setup capable of measuring structural dynamics following intense terahertz excitation. This system, developed at the SLAC Accelerator Structure Test Area facility, uses a high-energy ultrafast laser to produce intense terahertz pulses and femtosecond electron bunches that are accelerated to mega-electron-volt kinetic energies. The focused terahertz pulses have electric fields in excess of 600 kV/cm, and the resulting structural dynamics can be followed by electron diffraction. We also present some examples demonstrating its implementation where interactions between the THz pulses and the electron bunch are used to characterize the spatial and temporal characteristics of the THz field.
P06013
M. Sohrabi and A. Komijani
The effects of charge polarity and thickness on the surface charge potential stability responses of large-area Teflon polytetrafluoroethylene (PTFE) discs electrostatically charged by a new “modified single point-to-plane corona poling rotating system” were studied. Large-area Teflon discs (6 cm diameter) with 0.2, 0.5 and 1 mm thicknesses were used to produce both negatively or positively charged Teflon discs, at the same charging conditions. The deposited charge potential stability of the Teflon discs of different thicknesses monitored by a non-contacting electrostatic voltmeter for an extended time were monitored up to 77 days. Some inter-related parameters such as surface charge potential and external electrostatic field, internal electrostatic field, surface charge density, and the storage duration were also studied. The thick large-area Teflon disc electrets produced provided a steady-state charge stability on either negative (0.2, 0.5 and 1 mm thick) or positive (1 mm thick) surface charge potentials for the long period studied. The Teflon electret discs produced demonstrated having the highest charge potential stability in thicker electrets (1 mm), either negative or positive polarity, with provision of high potential for different applications in general and radiation protection dosimetry in particular.
P06012
H. Lin, D. Calvet, L. Chen, X. Chen, T. Dafni, C. Fu, J. Galan, K. Han, S. Hu, Y. Huo et al
We report the design, construction, and initial commissioning results of a large high pressure gaseous Time Projection Chamber (TPC) with Micromegas modules for charge readout. The detector vessel has an inner volume of about 600 L and an active volume of 270 L. At 10 bar operating pressure, the active volume contains about 20 kg of xenon gas and can image charged particle tracks. Drift electrons are collected by the charge readout plane, which accommodates a tessellation of seven Micromegas modules. Each of the Micromegas covers a square of 20 cm by 20 cm. A new type of Microbulk Micromegas is chosen for this application due to its good gain uniformity and low radioactive contamination. Initial commissioning results with 1 Micromegas module running with 1 bar argon and isobutane gas mixture and 5 bar xenon and trimethylamine (TMA) gas mixture are reported. We also recorded extended background tracks from cosmic ray events and highlighted the unique tracking feature of this gaseous TPC.
P06011
H.B. Feng, H.B. Liu, Q. Liu, Z.G. Wang, X.W. Liu, W.J. Xie, B. Huang, X.F. Huang, Y.H. Zheng and E.W. Liang
Micro Pattern Gas Detector (MPGD) coupled to an optical imaging system is a good candidate for detecting polarization of X-ray, dark matter, neutron, etc. In this paper, a MicroMegas detector is designed for detecting the photoelectron track of X-ray, which working gas compose of an Ar+CF4 mixture and optical signal readout with an ICCD. The correlation of scintillation light intensity and electrical current is obtained in the varying strength of the electric field at avalanche region, and the position resolution is 385 μm. The clear track images of the 241Am alpha source and 5.9 KeV X-ray are obtained, and the X-ray imaging is achieved in the experiment.
P06010
J. Hu, Z. Zhang, L. Chen, J. Liu, M. Yan, K. Zhao, S. He, M. Xu, L. Zhou, P. Jin et al
High sensitivity and good neutron/gamma discrimination, as well as online determination, are goals that researchers are pursuing for fast neutron spectrum measurements (FNSM). For this purpose, we are attempting a novel approach based on the recoil-proton track imaging (RPTI) method to do FNSM. The RPTI neutron spectrometer has been designed and built, and it mainly consists of a polyethylene foil for converting neutrons to protons, a gas scintillation chamber for generating photons along the recoil proton track, and a scientific camera system for recording the track photons in real time. Proof-of-principle experiments have been performed with the RPTI neutron spectrometer at a DT neutron generator at China Institute of Atomic Energy. As a result, numerous recoil proton track images at the single-particle level were successfully acquired and revealed in real time. Also, the proton tracks can be clearly distinguished from the background in the track images, indicating good signal-to-background ratio of the system. Particularly, both the proton ranges and the Bragg curve peak positions can be extracted online from the track images, which can lead to online generation of DT neutron spectra. These results show promising performance of the novel fast neutron spectrometer, which will bring significant advantages in various applications.
P06009
J. Smyrski, T. Fiutowski, P. Gianotti, A. Heczko, M. Idzik, M. Kajetanowicz, G. Korcyl, B. Korzeniak, R. Lalik, E. Lisowski et al
The design of straw tube detector modules developed for the PANDA Forward Tracker is presented. One module consists of 32 straws with 10 mm diameter, arranged in two staggered layers, and has a very low material budget of only 8.8⋅10−4X0. The overpressure of the working gas mixture of 1 bar makes the module self-supporting and enables the use of lightweight and compact support frames. Detection planes in the Forward Tracker consist of modules mounted closely, without gaps, next to each other on a support frame. A module can be mounted and dismounted from the frame without the need to remove the neighboring modules, enabling fast repairs. Technical details of the detector design and the assembly procedure of the straw tubes and the straw modules as well as results of performed tests of the modules are given.
P06008
The following article is Open access
M. Alexander, W. Barter, A. Bay, L.J. Bel, M. van Beuzekom, G. Bogdanova, S. Borghi, T.J.V. Bowcock, E. Buchanan, J. Buytaert et al
Precise knowledge of the location of the material in the LHCb vertex locator (VELO) is essential to reducing background in searches for long-lived exotic particles, and in identifying jets that originate from beauty and charm quarks. Secondary interactions of hadrons produced in beam-gas collisions are used to map the location of material in the VELO. Using this material map, along with properties of a reconstructed secondary vertex and its constituent tracks, a p-value can be assigned to the hypothesis that the secondary vertex originates from a material interaction. A validation of this procedure is presented using photon conversions to dimuons.
P06007
R.P. Rout, R. Mishra, R. Prajith, S.P. Tripathy, B.K. Sapra and S. Jalaluddin
As measurement of inhalation dose due to radon and thoron progeny is very important in indoor as well as occupational environments, the solid state nuclear track (LR-115) based passive progeny sensors such as Direct Radon Progeny Sensor (DRPS) and Direct Thoron Progeny Sensor (DTPS) are extensively used for this purpose. These detectors need to be chemically etched and spark counted for estimation of track density which is then converted into progeny concentration and finally into inhalation dose using appropriate calibration factors. But for high exposure situations, these detectors have limitations and leads to underestimation of dose. In the present study, we have investigated the possibility of using UV-Visible spectroscopy as an alternative way to estimate the track density in these detectors which can be converted into corresponding progeny concentrations and ultimately to inhalation dose. The transmission spectrum of these progeny sensors under UV-Visible spectrophotometer shows a characteristic peak about wavelength of 380 nm and the variation in transmission at this wavelength was analyzed against the varying alpha exposure. The variation of transmission at 380 nm was observed to be linear with respect to the track density and these linear relations could be used for estimating track density for unknown exposure. This method is a non-destructive alternative way of measuring track density in the DTPS and DRPS and it will be useful for high exposure conditions.
P06006
K. Kanxheri, L. Alunni Solestizi, M. Biasini, M. Caprai, A.C. Dipilato, M. Iacco, M. Ionica, S. Lagomarsino, M. Menichelli, A. Morozzi et al
Recently, a polycrystalline chemical vapor deposited (pCVD) 3D diamond detector with graphitic in bulk electrodes, fabricated using a pulsed laser technique has been evaluated for photon beam radiation dosimetry during in-air exposure. The same 3D diamond detector, has now been investigated to evaluate its performance under clinically relevant conditions putting the detector inside a Polymethylmethacrylate (PMMA) phantom, to obtain higher precision dosimetric measurements. The detector leakage current was of the order of ± 25 pA or less for bias voltages up to −100 V. The 3D detector was tested for time stability and repeatability showing excellent performance with less than 0.6% signal variation. It also showed a linear response for low dose rates with a deviation from linearity of 2%. It was also possible to verify the detector response as a function of the depth in PMMA up to 18 cm.
P06005
H. Hemmati, A. Kamali-Asl, P. Ghafarian and M.R. Ay
A challenge to have quantitative positron emission tomography (PET) images is to provide an accurate and patient-specific photon attenuation correction. In PET/MR scanners, the nature of MR signals and hardware limitations have led to a real challenge on the attenuation map extraction. Except for a constant factor, the activity and attenuation maps from emission data on TOF-PET system can be determined by the maximum likelihood reconstruction of attenuation and activity approach (MLAA) from emission data. The aim of the present study is to constrain the joint estimations of activity and attenuation approach for PET system using a mixture model prior based on the attenuation map histogram. This novel prior enforces non-negativity and its hyperparameters can be estimated using a mixture decomposition step from the current estimation of the attenuation map. The proposed method can also be helpful on the solving of scaling problem and is capable to assign the predefined regional attenuation coefficients with some degree of confidence to the attenuation map similar to segmentation-based attenuation correction approaches. The performance of the algorithm is studied with numerical and Monte Carlo simulations and a phantom experiment and was compared with MLAA algorithm with and without the smoothing prior. The results demonstrate that the proposed algorithm is capable of producing the cross-talk free activity and attenuation images from emission data. The proposed approach has potential to be a practical and competitive method for joint reconstruction of activity and attenuation maps from emission data on PET/MR and can be integrated on the other methods.
P06004
The following article is Open access
S. Aghion, C. Amsler, M. Antonello, A. Belov, G. Bonomi, R.S. Brusa, M. Caccia, A. Camper, R. Caravita, F. Castelli et al
Studies of antimatter are important for understanding our universe at a fundamental level. There are still unsolved problems, such as the matter-antimatter asymmetry in the universe. The AEgIS experiment at CERN aims at measuring the gravitational fall of antihydrogen in order to determine the gravitational force on antimatter. The proposed method will make use of a position-sensitive detector to measure the annihilation point of antihydrogen. Such a detector must be able to tag the antiproton, measure its time of arrival and reconstruct its annihilation point with high precision in the vertical direction. This work explores a new method for tagging antiprotons and reconstructing their annihilation point. Antiprotons from the Antiproton Decelerator at CERN were used to obtain data on direct annihilations on the surface of a silicon pixel sensor with Timepix3 readout. These data were used to develop and verify a detector response model for annihilation of antiprotons in this detector. Using this model and the antiproton data it is shown that a tagging efficiency of 50± 10% and a vertical position resolution of 22 ± 0.5 μm can be obtained.
P06003
M.A. Abdalla, M.H. Ghouz and M. Abo El-Dahab
In this paper, two different designs for new metamaterial loaded dipole antenna are presented. The designs are based on loading printed dipole antennas with modified versions of composite right left handed cells. Different objectives are intended for these new designs; which are achieving compact size, dual band functionalities and good gain of the loaded dipole antenna. The designed antennas can serve different wireless services for GPS (1.227 GHz and 1.57 GHz), Universal Telecommunications System (UMTS 1.9 GHz), and WiFi (2.4 GHz). The two presented antennas have gain whose values are better than 1.9 dB up to 3.5 dB at all operating frequencies. The designed loading has reduced the physical / electrical length of conventional dipole antenna by 25%. The theoretical analysis, circuit model, full wave simulations and experimental measurements of the reported antennas are introduced.
P06002
M. Rongen and M. Schaufel
Many experimental setups, such as for the calibration of photosensors, require light sources with sub-nanosecond timing precision. We present the design and evaluation of a brightness controlled, picosecond light pulser based on an avalanche transistor pulse driving circuit. It can be used with a large variety of LEDs and VCSELs, enabling usage over a wide wavelength range, with light curves as short as ∼ 100 ps standard deviation.
P06001
The following article is Open access
T. Bretz, R. Engel, T. Hebbeker, J. Kemp, L. Middendorf, C. Peters, J. Schumacher, R. Šmída and D. Veberič
Silicon photomultipliers (SiPMs) are semiconductor-based light-sensors offering a high gain, a mechanically and optically robust design and high photon detection efficiency. Due to these characteristics, they started to replace conventional photomultiplier tubes in many applications in recent years. This paper presents an optical module based on SiPMs designed for the application in scintillators as well as lab measurements. The module hosts the SiPM bias voltage supply and three pre-amplifiers with different gain levels to exploit the full dynamic range of the SiPMs. Two SiPMs, read-out in parallel, are equipped with light guides to increase the sensitive area. The light guides are optimized for the read-out of wavelength shifting fibers as used in many plastic scintillator detectors. The optical and electrical performance of the module is characterized in detail in laboratory measurements. Prototypes have been installed and tested in a modified version of the Scintillator Surface Detector developed for AugerPrime, the upgrade of the Pierre Auger Observatory. The SiPM module is operated in the Argentinian Pampas and first data proves its usability in such harsh environments.
Conference proceedings
C06008
E.I. Jussiani, M.V. Colaço, L. Kuplich, F. Carrerete, R. Pinto, R. Cély Barroso, C.R. Appoloni and L. Parreiras Nogueira
Urinary stone is a common clinical problem whose most frequent chemical compositions are calcium oxalate, calcium phosphate, uric acid and cystine. In this work we propose a new method for quantification of urinary stones using single-energy computed tomography (SECT). The results were validated with X-ray powder diffraction (XRPD). The proposed SECT method consists of obtaining a calibration curve that relates the gray levels of the sample with its density and effective atomic number. XRPD results showed that one of the samples is purely composed of uracite, another is a mixed stone composed of hydroxyapatite and struvite, and the last one is composed of hydroxyapatite and calcium oxalate monohydrate (whewellite). X-ray computed microtomography (micro-CT) results showed that the standard samples presented an excellent correlation. The gray levels of the studied samples were determined theoretically through the calibration curve and its values agreed with the experimental results. The XRPD results reinforced the data obtained by micro-CT.
C06007
R.M. Nazhmudinov, P. Karataev, A. Kubankin, K. Lekomtsev, A. Potylitsyn and A. Vukolov
In this report we describe a new facility designed, manufactured and commissioned at Belgorod National Research University. It is a compact and cost-efficient low energy continuous electron beam installation developed to underpin research and education foundation of the University group. We present the measurements of the beam size, emittance, position and trajectory. A THz detection beam line has also been constructed and tested. The status of the THz radiation generation programme, future upgrades and experimental plans have been described.
C06006
D. Micieli, T. Minniti, V. Formoso, W. Kockelmann and G. Gorini
Neutron Tomography (NT) is an established technique to non-destructively investigate the inner structure of a wide range of objects. The major drawback of NT is the long acquisition time required to perform a tomographic scan compared to an X-ray Computed Tomography (CT) scan, due to the limited particle flux of the existing neutron sources. Therefore, in the NT field there is great interest in the reduction of scan time, dictated by the high neutrons production cost, aimed at optimizing the beamtime use at neutron imaging beamlines. A way for decreasing the total scan time is to reduce the number of projections. Generally, iterative reconstruction methods have advantages over analytical algorithms, such as the widely used Filtered Back-Projection (FBP), when data are noisy and limited. This research is focused on the comparative analysis of different reconstruction techniques, aimed at finding the data processing procedure suitable for NT, that reduces the scan time without reduction of the reconstructed image quality. For this purpose, a phantom sample was analysed by means of a white beam NT performed at the IMAT beamline, ISIS Neutron Source, U.K . Experimental data were used to test the performances of the FBP algorithm and different iterative reconstruction methods as a function of the number of projections and for different setups of the imaging system. The reconstructed images were quantitatively compared in terms of image quality indexes and the benefits of iterative methods for the limited data problem are discussed.
C06005
A. Haidl, K. Andrianov, T. Nisius, L. Lühl, A. Dehlinger, H. Dierks, R. Gnewkow, B. Kanngießer and T. Wilhein
This paper presents a setup for the fast detection of soft x-rays using a high speed camera as multimodal detector for application in the AnImaX scanning transmission x-ray microscope (STXM). AnImaX is a flexible endstation for combining scanning and full field microscopy for the XUV beamline P04 at PETRA III. While using the scanning mode there is the additional option to gather fluorescence spectra for each scanned pixel. Because of the brilliance of the P04 beamline, fast image acquisition is possible and in consequence demands a fast and efficient data management.
C06004
M. Havranek, T. Benka, M. Hejtmanek, Z. Janoska, V. Kafka, J. Kopecek, M. Kuklova, M. Marcisovska, M. Marcisovsky, G. Neue et al
In this work, we present a prototype of the Monolithic Active Pixel Sensor (MAPS) called X-CHIP-02 designed in 180 nm SOI CMOS technology. The selected technology has attractive features for fabrication of X-ray imaging sensors: 100 Ω⋅ cm handle wafer resistivity, thick epitaxial layer to suppress back-gate effect, support of high voltage devices and deep trench isolation. X-CHIP-02 has two pixel matrices with the pixel pitch of 50 μm and 100 μm with integrated 8-bit photon counting circuitry. Fine pitch SOI monolithic pixels imply small capacitance and thus small electronic noise of ≈50 e−. Design of the sensor chip and basic radiation imaging capabilities are described in this paper.
C06003
L. Pascolo, I. Venturin, A. Gianoncelli, M. Salomé, M. Altissimo, D.E. Bedolla, E. Giolo, M. Martinelli, S. Luppi, F. Romano et al
Many clinical circumstances impose the necessity of collection and prolonged storage of gametes and/or ovarian tissue in order to preserve the reproduction potential of subjects. This is particularly appropriate in the case of young women and pre-pubertal girls undergoing chemotherapeutic treatments. The success of later assisted fertilization will depend on the suitable cooling protocols minimizing cryo-damages and preserving their biological function. The freeze-thaw processes of cryopreservation may induce, in fact, morphological and structural damages of oocytes and tissue mainly due to the formation of intracellular ice and to the toxicity of cryoprotectant. The most used cryo-protocol is the slow freezing procedure, but recently many authors have proposed vitrification as an alternative, because of its simplicity. The damage extent and the quality of follicles after cryopreservation are usually evaluated morphologically by conventional histological procedures, light and electron microscopy. Our laboratory, to further improve the evaluation and to better investigate damages, is adopting a combination of Synchrotron soft X-ray Microscopy (at TwinMic – Elettra) and XRF at different incident energies (at TwinMic – Elettra and ID21 – ESRF). X-ray techniques were performed on histological sections at micro and sub-micron resolution. Phase contrast and absorption images revealed changes in the compactness of the tissues, as well as cellular abnormalities revealed at sub-micrometric resolution. The distributions of the elements detected at 7.3 and 1.5 keV were compared and particularly Cl resulted to be indicative of follicle integrity. The results demonstrate the utility and the potential of X-ray microscopy and fluorescence in this research field.
C06002
F. Guzzi, G. Kourousias, F. Billè, R. Pugliese, C. Reis, A. Gianoncelli and S. Carrato
Ptychography is an advanced technique whose latest developments have allowed for exceptionally high resolution in X-ray microscopy, as well as new setups that can even be lensless; the spatial resolution has already reached <5 nm in synchrotron beamlines. Still there are certain demanding requirements such as beam coherence and strong involvement of computational methods that make it a rather difficult technique to implement. In this paper we introduce a computational work-flow aiming at refining the individual probe positions of a ptychography scan. Indeed, the precision of those positions is of high importance as it impacts the reconstruction. Special setups using precise sample stages with nanopositioning and advanced interferometers are important; however, positioning errors still remain a problem for many operating laboratories. This paper examines the Structural Similarity Index as a suitable metric for evaluating the registration in alignment of individually reconstructed probes. Eventually it suggests the use of Machine Learning techniques as future direction in probe alignment. It also presents a new software tool for precise manual alignment and visualization. All the software developed during this research project is provided to the scientific community as open source.
C06001
T.M.P. Santos, A.S. Machado, O.M.O. Araújo, C.G. Ferreira and R.T. Lopes
X-ray computed microtomography (microCT) is a powerful nondestructive and noninvasive technique for 2D and 3D structure analyses. However, the parameters used in the image acquisition process have a direct influence on the qualitative and quantitative results, such as porosity, and on the characterization of samples, such as carbonate rocks, due to the spatial resolution of the image. The aim of this study is to determine the influence of these parameters on the results through tests in which these parameters are changed in different scenarios and system characterizations. In addition, with the optimum parameters, the whole sample image was acquired for characterization and compared to the homogeneity and representativeness of one part of the sample. The results demonstrate that the pixel size and detector matrix are the main parameters that influence the spatial resolution and that the use of additional filters for better image quality is essential. Microtomography is considered an excellent technique for rock characterization by using the best image spatial resolution possible.
Technical reports
T06007
T. Xue, J. Zhu, G. Gong, L. Wei and J. Li
High-speed pulse digitalization is critical for modern physics experiments with photomultiplier tubes (PMTs). This prototype design integrates the high-speed analogue to digital converter (ADC) for pulse digitalization, high voltage generator, high-speed buffer, synchronized clock, PoE (Power over Ethernet) power management and ZYNQ SoC (System on Chip) in a compact base which can be mounted with the PMT directly. There is only one category 5 Gigabit Ethernet cable needed for power, data and synchronized timing. This integrated design can be used to replace the conventional readout electronics system with PMTs which use the discrete or integrated pulse shaping circuit and FADC boards based on NIM or VME system. In the applications of several PMTs are used, or in the system where thousands of PMTs are deployed, this prototype design of integrated base for PMT has advantages to simplify the tremendous long distance analogue cables and high voltage cables. This paper presents the mechanical and hardware design, challenges and software design, the ENOB (effective number of bits) of ADC and the TCP data throughput of the Gigabit Ethernet will also be discussed. A scintillator neutron detector mounted with PMTs is connected to this prototype and spectrum analysis with the 137Cs γ source is performed to verify the system function; the preliminary results are also illustrated.
T06006
O. Jakovlevs, A. Pchelintsev, V. Malgin, A. Sokolov and V. Gostilo
We have developed two miniaturized HPGe gamma spectrometers for airborne environmental monitoring with unmanned aerial vehicles (UAVs). The spectrometers have been optimised for UAVs with a load capacity of up to 10 kg, a control radius of up to 3 km and a flight endurance without recharging of up to 30 min at a loading of 6 kg. The weights of the spectrometers with Stirling electrical cooling and cooling by liquid nitrogen were 5.8 and 2.6 kg, respectively. Both spectrometers were tested at two photon energy levels—122 keV and 1332 keV. Energy resolution with electrical cooling was 2.1 keV and 2.6 keV while the spectrometer with liquid nitrogen cooling had energy resolution of 1.2 keV and 2.2 keV when tested at the same energy levels.
T06005
G. Adhikari, P. Adhikari, C. Ha, E.J. Jeon, K.W. Kim, N.Y. Kim, Y.D. Kim, Y.J. Ko, H.S. Lee, J. Lee et al
A monitoring system for fast neutrons is planned in the COSINE experiment, a dark matter experiment with NaI crystals. We pursued several R&D approaches for a neutron detector using a liquid scintillator (LS). A pulse shape discrimination (PSD) technique is used for the identification of neutron events and the PSD properties of two different LS were compared. A good separation power between neutrons and γ has been achieved for energies between 200 keVee to 1500 keVee. The combination of alumina adsorption, filtration, and water extraction is effective in purifying the LS, which leads to a reduction in the α contamination by 210Po of more than a factor of two. The measured activities of the internal α are 0.36±0.04 mBq/kg and 0.21±0.03 mBq/kg before and after purification, respectively.
T06004
W. Yudong, L. Xiaobing, Z. Chi, Z. Rong and Y. Chaowen
In order to measure the gamma dose more accurately than before, methods of spectrum-dose conversion have been in practice more often instead of count-dose conversion. There are two common methods that have been developed and published. They are the method of G(E) function and the method of unfolding spectrum. The method of G(E) function has been applied in the instrument, because it is easier to implement with limited resources of embedded computers. It is reported that the method of unfolding spectrum cannot only obtain the gamma dose, but also identify nuclides. In this paper these two methods were compared with each other using same initial data. The data was acquired by NaI(Tl) scintillation detectors and other relevant nuclear electronic instruments with three gamma radiation point sources 137Cs, 60Co and 152Eu. The simulation software Geant4 has been used in both methods to calculate the response function and matrix. Results were presented and compared with each other, and all relative deviations were better than 15%.
T06003
The following article is Free article
J-P. Delahaye, C.M. Ankenbrandt, S.A. Bogacz, P. Huber, H.G. Kirk, D. Neuffer, M.A. Palmer, R. Ryne and P.V. Snopok
A Neutrino Factory where neutrinos of all species are produced in equal quantities by muon decay is described as a facility at the intensity frontier for exquisite precision providing ideal conditions for ultimate neutrino studies and the ideal complement to Long Baseline Facilities like LBNF at Fermilab. It is foreseen to be built in stages with progressively increasing complexity and performance, taking advantage of existing or proposed facilities at an existing laboratory like Fermilab. A tentative layout based on a recirculating linac providing opportunities for considerable saving is discussed as well as its possible evolution toward a muon collider if and when requested by Physics. Tentative parameters of the various stages are presented as well as the necessary R&D to address the technological issues and demonstrate their feasibility.
T06002
B. Mukherjee
The ratio of thermoluminescence glow curve area of BeO and LiF dosimeters was found to be proportional to average LET and quality factor (Q) of impinging mixed radiations. Using this phenomenon and widely available Thermoluminescence Dosimeter TLD-700 (7LiF: Mg,Ti) and BeO (Thermolux 995) chips a TLD-Microdosimeter (LiBe-14) emulating a much larger gas-filled Tissue Equivalent Proportional Counter (TEPC) was developed. The TEPC is an essential device of space radiation dosimetry widely used by international space agencies. The LiBe-14 is capable of assessing the LETTissue (5–300 keV/μm), quality factor Q (1–30) and associated dose equivalent H (0.1–1000 mSv) of any mixed radiation fields of interest, including space radiations predominant in Low Earth Orbit (LEO) environment. The TLD microdosimeter was calibrated using the secondary radiation fields produced by bombarding a 25 cm × 25 cm × 35 cm polystyrene phantom with 81, 119, 150, 177, 201 and 231 MeV protons from a Proton Therapy Medical Cyclotron. The TLD pair (BeO/LiF) was attached to the TEPC and placed lateral to the proton beam. The characteristics of space radiation inside the spacecraft are complex. Hence, personal dosimetry of astronauts in the space habitat is performed using “multi-element” dosimeters made of different types of TLD and CR-39 plastic nuclear track detector (PNTD). The TLD and PNTD are used to assess the sparsely (low LET) and densely (high LET) ionising radiation component respectively. This report elucidates the feasibility of LiBe-14 microdosimeter for the estimation of overall dose equivalent and “risk of exposure induced death” (REID) of astronauts working in LEO space stations.
T06001
P. Vitulo
We succeeded in modifying and controlling the electrical resistance of a standard High Pressure Laminate (HPL) panel through the use of a Gas Electron Multiplier (GEM) foil that has been embedded into the bulk of the HPL plate itself. Electrical characterizations were made and preliminary data show that this HPL-GEM embedded system can easily vary its bulk resistance by more than one order of magnitude. Data show that the bulk resistance change is exponential with the applied voltage to the embedded GEM.