The following article is Free article

Electrochemical Impedance Spectroscopy on Lead Acid Battery Positive Active Material

, and

© 2025 ECS - The Electrochemical Society
, , Citation Frederick Agyapong-Fordjour et al 2025 Meet. Abstr. MA2025-02 907DOI 10.1149/MA2025-026907mtgabs

2151-2043/MA2025-02/6/907

Abstract

Aqueous batteries are poised to play a key role in grid energy storage solutions, given their low flammability and abundant materials. Battery condition indicators, such as the state of charge (SOC) and state of health (SOH), are critical for effective battery monitoring and control. However, these indicators are not easily accessible from simple voltage/current measurements and must instead be estimated using models. This is challenging because they are influenced by operating conditions such as temperature and charge/discharge rates, resting periods, etc. Electrochemical impedance spectroscopy (EIS) is a valuable tool for tracking the SOH of batteries. It can accurately determine equivalent resistances, which help characterize electrochemical processes through parameters like ohmic (solution) resistance (Rs), charge transfer resistance (Rct), and double layer capacitance (Cdl). These parameters can, in turn, help estimate the electrochemical active surface area (ECSA). In our study, we used EIS to monitor Cdl, Rct, and Rs of the positive active materials (PAM) in lead-acid batteries. This approach allowed us to investigate battery failure mechanisms, such as material loss and grid corrosion, which are influenced by charge cut-off potential and gassing reactions. We found a correlation between Rct and Rs, as gassing leads to material loss due to changes in adhesion and cohesion within the active material, causing expansion and grid corrosion. Further, a clear correlation was observed between discharge voltage drop and reductions in Cdl, ECSA, and electrode capacity. Notably, a decline in real surface area (ECSA) prior to any noticeable decrease in electrode capacity is revealed from EIS analysis. Therefore, EIS-derived metrics like Cdl, Rct, and Rs could serve as indicators of the state of health for the positive active materials in lead-acid batteries.

Acknowledgements: The research was conducted at Argonne National Laboratory, a U.S. Department of Energy Office of Science laboratory, operated by UChicago Argonne, LLC under Contract no. DE-AC02-06CH11357. The authors acknowledge the support from the Lead Battery Science Research Program via a Collaborative Research and Development Agreement. The submitted abstract has been created by UChicago Argonne, LLC, Operator of Argonne National Laboratory (“Argonne”). Argonne, a U.S. Department of Energy Office of Science laboratory, is operated under Contract No. DE-AC02-06CH11357. The U.S. Government retains for itself, and others acting on its behalf, a paid-up nonexclusive, irrevocable worldwide license in said article to reproduce, prepare derivative works, distribute copies to the public, and perform publicly and display publicly, by or on behalf of the Government. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan. http://energy.gov/downloads/doe-public-access-plan

Export citation and abstractBibTeXRIS

10.1149/MA2025-026907mtgabs