Abstract
This paper introduces a method to determine the located region of trap position by the analysis of three-level random telegraph signal (RTS) in partially-depleted silicon-on-insulator n-channel metal-oxide-semiconductor field-effect-transistors. For the cases of two traps, the average time at the 2nd level (〈τ2〉) is composed of average emission time of one trap and average capture time of the other. Comparison and analysis of 〈τ2〉 curves varying with gate voltage in RTS measurements with and without interchanged source/drain can clarify the located regions of the two traps. Moreover, the simplified equations are also considered and used to confirm the trap positions.
Access this article
The computer you are using is not registered by an institution with a subscription to this article. Please choose one of the options below.