Lead storage batteries were allowed to stand after preparation, and were then recharged and tested. A marked increase in the initial yields was observed for standing periods of 30 days or more, especially in the case of batteries containing fairly dense positives such as would normally increase in capacity during continued cycling. The self‐discharge of duplicate batteries was also investigated as a possible explanation of the increase in capacity on standing.