Abstract
A consistent set of rate constants describing simultaneous
and CO adsorption and electro-oxidation in a proton exchange membrane fuel cell with high-performance membrane electrode assemblies is reported. The parameters were estimated from regression of a first-principles model to anode overpotential data collected at 70 and
at 101 and 202 kPa. A Langmuir isotherm was found to be sufficient for the CO adsorption equilibrium for this catalyst when the Heyrowski–Volmer mechanism for
oxidation on a Pt/Ru–C catalyst is used. These parameters and the ability to predict performance loss that are critical as standards for hydrogen quality are established.
Access this article