The design and operation of a laboratory electrolytic cell for the production of ductile Ti with continuous Equation or symbol description not availableTiCl4 feed is described. The cell is metal, with an alumina diaphragm; the electrolyte is Equation or symbol description not availableLiCl‐KCl‐NaCl plus several per cent Ti ion, at 550°C. Reproducibility of results was good, and the cell was used chiefly to study the effects of varying operating conditions on metal quality. Observations are reported on the influences of Ti ion valence and concentration, current density, agitation, salt melt purity, air leakage, and gaseous and metallic impurities on the cathode deposit. A pronounced improvement in metal quality, with no sacrifice in yield, was achieved by delaying the immersion of the main deposition cathode for a considerable period after the start of electrolysis.