The effect of the electrode size on the diffusion current of the cathodic reaction Equation or symbol description not availableI3−+2e=3I− was investigated under transient conditions. Plane circular surfaces of platinum electrodes with diameters, d, ranging from 1.27 to 0.0127 cm were used. The diffusion current under potentiostatic conditions could be expressed as

Equation or symbol description not availablei=nFADCπ 1t+2MπDd

where Equation or symbol description not availableM is an empirical parameter which is a function of Equation or symbol description not availabled. For Equation or symbol description not availabled<0.1 cm,M=1 and the diffusion mode was equivalent to semi‐infinite spherical diffusion. On the other hand, for Equation or symbol description not availabled>0.3 cm,M=0, and semi‐infinite linear diffusion was the controlling mode. The change in the diffusion mode occurred rather abruptly at about Equation or symbol description not availabled=0.2 cm.