Abstract
It has been shown that treatment of cast antimonial lead alloys with mixtures of hydrogen peroxide and sulfuric acid at 20° C dissolves surface antimony at an appreciably greater rate than occurs with sulfuric acid alone, even at elevated temperatures. Optimum hydrogen peroxide‐sulfuric acid reagent compositions have been established for the maximum solution of antimony from the alloy. A correlation exists between the quantity of antimony removed by this treatment and the quantity of antimony that is subsequently released from the alloy into sulfuric acid electrolyte when it is set up as an anode against pure lead cathodes. Batteries made using positive grids which have been pickled in hydrogen peroxide‐sulfuric acid mixtures, then brightened by dipping in a 10% aqueous solution of diethylene triamine have been shown to have a greater life on charge/discharge cycles than batteries made using standard unpickled grids.
Access this article