Abstract
The performance characteristics of the
cell have been determined as a function of discharge rate, electrolyte composition, cathode thickness, and cell temperature. Cells have been discharged at rates ranging from about 3 to nearly 300 mA/cm2. Cathodes with electrolyte solutions have contained either
or
, with the most efficient discharge characteristics being realized with
and
solutions. The use of pure
dissolved in
as the electrolyte results in substantially higher average discharge voltages and discharge capacities than can be achieved with cells containing the conventional
electrolyte. With both electrolytes, however, the discharge capacity per unit cathode volume (the effective cathode utilization) decreases with increasing cathode thickness, the rate of decrease being greater the higher the discharge current density. Increasing cell temperature results in an improvement in cathode utilization and a decrease in overvoltage, again with both
and
electrolyte solutions.
Access this article