Galvanostatic transients arising from multi‐step processes of the type: Equation or symbol description not availableν0O+ne=νRR are treated mathematically for systems subjected to both activation and diffusion control. Analysis of error based on the error matrix is presented. The galvanostatic method is characterized by the information contents [Equation or symbol description not availableI̅(i0) and Equation or symbol description not availableI̅(Cdl)] for a single‐estimate analysis (i.e., estimate of Equation or symbol description not availablei0 for known Equation or symbol description not availableCdl or the reverse) and that for a two‐estimate analysis (simultaneous determination of Equation or symbol description not availablei0and Equation or symbol description not availableCdl). The correlation between the estimates of Equation or symbol description not availablei0 and Equation or symbol description not availableCdl is given as a function of the dimensionless scale Equation or symbol description not availableT/τc. Information contents for Equation or symbol description not availablei0 and Equation or symbol description not availableCdl in single and two‐estimate systems are given and this permits the determination of the accuracy and the limits of the method as well as the choice of optimal experimental conditions. The optimal full time scale for estimation of Equation or symbol description not availablei0 depends on the value of Equation or symbol description not availableτc/τd. For Equation or symbol description not availableτc/τd between 0.5–500, Equation or symbol description not availableTopt/τc varies from 6 to 18 (single‐estimate system) and from 4 to 25 (two‐estimate system). The upper limit for Equation or symbol description not availablei0 in a single‐parameter estimation is 3–12 A cm−2 (for Equation or symbol description not availableCdl 10–40 μF cm−2) and the upper limit for Equation or symbol description not availableks(αa=αc=0.5) is 8 cm sec−1. This is three times greater than Equation or symbol description not availableks for the coulostatic method. For a given value of Equation or symbol description not availableks, the accuracy of the galvanostatic method is better than that of the coulostatic for systems when Equation or symbol description not availableτc/τd>0.6, but is not as good when Equation or symbol description not availableτc/τd<0.6. The upper limit of Equation or symbol description not availableks and the accuracy of the galvanostatic method for two‐estimate analysis (Equation or symbol description not availablei0 and Equation or symbol description not availableCdl) are considerably lower than those for single‐estimate analysis. An iteration method is developed with which a large improvement is achieved. Estimation ofEquation or symbol description not availablei0 and Equation or symbol description not availableCdl with a computerized curvilinear regression analysis is proposed.