Corrosion and redox potentials measured at 285°C against a zirconium oxide, membrane‐type pH sensor have been found to be more stable than similar measurements against more conventional reference electrodes. This is attributed to the excellent resistance of zirconium oxide to attack by high temperature water and to the absence of a liquid junction that permits exchange of an internal filling solution with the medium being monitored.