Several characteristics of Equation or symbol description not availableSiS2‐Li2S‐LiX glasses have been measured using ac and dc techniques. The ionic conductivity of isostatically pressed pellets with Equation or symbol description not availableTiS2 electrodes was studied as a function of pressing conditions, temperature, and electrolyte thickness. The electrolyte thickness study showed significant electrode/electrolyte contact resistance withEquation or symbol description not availableTiS2‐filled polymer sheets, but essentially no contact resistance with pressed powder Equation or symbol description not availableTiS2. Cells containing lithium electrodes showed the importance of using fresh, high purity lithium foil. Galvanic cells, Equation or symbol description not availableLi/glass/TiS2, exhibited OCV of 2.65V at 20°C and 10–15 mA/cm2 could be drawn for short periods of time with <0.3V polarization (IR‐free) at ambient temperature.