This paper presents a performance test of a 110 cm2 molten carbonate fuel cell bench cell as a function of output current and gas utilization. These results are compared with the predictions of cell performance of two analytical models, the simple and extended model, for which a revised derivation is given. A comparison of measurements and models results in a value for the quasi-ohmic resistance, r, of 1.02 and 1.07 Ω cm2, respectively, for the simple model and the extended model. Using this as the only fitted parameter and other theoretical parameters, the simple and the extended model describe the cell performance with a relative error of at most 5 and 1%, respectively, for fuel utilization above 10%. Both models have therefore shown their reliability. © 2001 The Electrochemical Society. All rights reserved.