Abstract
We report that the thermal wall load due to locked modes can be decreased by means of gas puffing in the reversed-field pinch (RFP) device, TPE-RX [Y. Yagi et al.: Fus. Eng. Design 45 (1999) 409]. Under standard RFP operation in TPE-RX, the phase- and wall-locked modes, i.e., spatially localized and stationary magnetic perturbations, respectively, appear after the current-rising phase. The locked modes cause a severe thermal wall load of the order of 100 MW/m2 on the first wall. It is estimated that the temperature on the plasma-facing wall at the mode-locking position sometimes exceeds the melting temperature of stainless steel. The thermal wall load increases with plasma current, Ip. We have succeeded in mitigating the high thermal wall load by gas puffing during discharges. It is shown that the maximum temperature increment of the vacuum vessel wall is halved when a gas-puffing rate of 200 Pa m3/s is applied at Ip=350 kA. The characteristics of the temperature increase of the vacuum vessel are presented, and they indicate the nature of the locked mode in RFP discharges in TPE-RX.
Access this article
The computer you are using is not registered by an institution with a subscription to this article. Please choose one of the options below.