Abstract

The characterization of mobile charge carriers of semiconductor materials has spurred the development of numerous two dimensional carrier profiling tools. Here, we investigate the mobile charge carriers of several samples by multi-harmonic electrostatic force microscopy (MH-EFM) and scanning microwave impedance microscopy (sMIM). We present the basic principles and experiment setups of these two methods. And then several typical samples, i.e. a standard n-type doped Si sample, mechanical exfoliation and chemical vapor deposition grown molybdenum disulfide (MoS2) layers are systemically investigated by sMIM and MH-EFM. The difference and (dis)advantages of these two modes are discussed. Both modes can provide carrier concentration profiles and have sub-surface sensitivity. They also have advantages in sample preparation in which contact electrodes are not required and insulating or electrically isolated samples can readily be studied. The basic mode, physics quantities extracted, dielectric response form and parasitic charges in scanning environment result in difference in experiment results for these two kinds of methods. The techniques described in this study will effectively promote research on basic science and semiconductor applications.

Export citation and abstract BibTeX RIS

Original content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

1. Introduction

Two dimensional (2D) semiconductor materials is the foundation of modern electronics and performance of their devices is influenced by electrical parameters such as carrier type, dopant concentration, defects densities and so on. Hence, the development of semiconductor industry demands for sub 10 nm resolution, combined with sufficient sensitivity (down to the 1015 atoms cm–3 level) and high-quantification accuracy over a dynamic range of 1015–1020 atoms cm–3 [1]. The need for such an extreme spatial resolution as well as the applicability towards standard devices has spurred the development of numerous 2D carrier profiling tools. Until today, various methods have been developed for this purpose, such as secondary ion mass spectrometry, field-effect scanning electron microscopy, etc. One category of these methods is scanning probe microscopy (SPM)-based techniques.

SPM is implemented by position various types of probes in very close proximity with extremely high precision to the sample. These probes can detect electrical current, atomic and molecular forces, electrostatic forces, or other types of interactions with the sample. SPM-based mobile charge carriers detection methods include scanning Kelvin probe force microscopy (SKPM) [24], scanning capacitance microscopy (SCM) [5, 6], scanning surface harmonic microscopy (SSHM) [7] and scanning spreading resistance microscopy (SSRM) [8, 9], etc. The SKPM methods can measure contact potential difference between the probe and sample surface, which is dependent on the carrier concentration-related work function difference, and can qualitatively obtain the local carrier concentration. In the SCM, tip–sample contact forms a metal–insulator–semiconductor (MIS) capacitor, whose local carrier type and concentration can be obtained by capacitance–voltage (CV) behavior. In the SSHM (consists with a STM with a microwave cavity), the nonlinear tip–sample MIS capacitance C results in higher-order harmonics in the tunneling current. The capacitance is a measure for the local active carrier concentration of the semiconductor in the same way as in the SCM technique. In SSRM method, the local carrier concentration depends inverse proportionally on the spreading resistance around the probe–sample contact. Although the above methods can characterize the charge carrier type and concentration of sample, they are restricted by limited sensitivity, laborious sample preparation, destructive of sample, lower signal-to-noise ratio and others.

The newly-developing powerful method scanning microwave impedance microscopy (sMIM) is a promising tool for 2D mobile charge carriers profiling with nanometer resolution [1020]. It also has advantages in sub-surface scanning ability and simple in sample preparation [21]. Considering the limitation of fiscal condition, multi-harmonic electrical force microscopy (MH-EFM) can be used in mobile charge carriers characterization of semiconductor 2D materials [22]. An exhaustive delineation of the mobile charge carriers characterization by the sMIM and MH-EFM needs further investigated theoretically and experimentally.

Here, the mobile charge carriers profiling of several samples has been investigated by multi-harmonic electrostatic force microscopy (MH-EFM) and sMIM, respectively. We present the basic principles and experiment setups of these two methods. And then several typical samples, i.e. a standard n-type doped Si sample, mechanical exfoliation and chemical vapor deposition (CVD) grown molybdenum disulfide (MoS2) layers are systemically investigated by sMIM and MH-EFM. The difference and (dis)advantages of these two modes are discussed. Both modes can provide carrier concentration profiles and have sub-surface sensitivity. They also have advantages in sample preparation, which do not need electrode preparation on samples. The basic mode, physics quantities extracted, dielectric response form and parasitic charges in scanning environment result in difference experiment results of these two kinds of methods.

2. Basic principles and experimental setup

sMIM is a combination of microwave technology and AFM, which has demonstrated a very broad range of applications. sMIM was proposed by Lai et al and developing quickly these years [10, 11, 23, 24]. It can detect many kinds of electrical properties of various samples (including conductors, semiconductors, insulators and other functional materials) at the micro/nano scale [14, 2535].

Figure 1 illustrates the microwave electronics. Generally speaking, a gigahertz (GHz) signal applied to a scanning probe to detecting the complete complex-valued tip−sample impedance Ztip–sample, which results from the local electronic properties. Because of the large mismatch between tip–sample impedance Ztip–sample and the transmission line impedance Z0 = 50 Ω, impedance matching section is need to maximizing the microwave power delivered to probe [10, 11]. As shown in figure 1, firstly, microwave transmits into the probe from the microwave source. Then microwave near-field interacts with sample and backtracks. The microwave reflection coefficient is ${\rm{\Gamma }}=\displaystyle \frac{{Z}_{{\rm{t}}{\rm{i}}{\rm{p}}\mbox{--}{\rm{s}}{\rm{a}}{\rm{m}}{\rm{p}}{\rm{l}}{\rm{e}}}-50\,{\rm{\Omega }}}{{Z}_{{\rm{t}}{\rm{i}}{\rm{p}}\mbox{--}{\rm{s}}{\rm{a}}{\rm{m}}{\rm{p}}{\rm{l}}{\rm{e}}}+50\,{\rm{\Omega }}}.$ A cancellation signal is provided to suppress the background so that small changes can be amplified without saturating the output. And finally amplified signal demodulated by the mixer M1. The effective tip–sample impedance can be divided into two parts—the real and imaginary parts. Standard dielectric sample (Al2O3@SiO2) is needed to calibration the phase of the M1, until the output contrast only occurs in one channel (this is imaginary part of Ztip–sample, sMIM-Im). The other channel is the real part of Ztip–sample (sMIM-Re). For semiconductors or insulators, the sMIM-Im and sMIM-Re are corresponding to the capacitance (C) and resistance (R) between tip–sample, respectively, as shown in the insert image lumped element model.

Figure 1.

Figure 1. A schematic of sMIM setup. The shielded probe connected with microwave source (∼GHz frequency band). Microwave transmits into the probe, near-field interacted with the sample, and then reflection microwave backtrack. The reflected signal is suppressed by the common-mode cancellation through a directional coupler (D), amplified by radio frequency (RF) amplifiers (A), and then demodulated by a quadrature mixer (M1). sMIM-Im and sMIM-Re information can be obtained. The signal further modulated by quadrature mixer M2, dC/dV and dR/dV can be obtained. Insert: schematic of lumped element model.

Standard image High-resolution image

An alternating current (AC) voltage with frequency ∼kHz is applied to the tip as a modulation voltage. Using the quadrature mixer M2, dC/dV and dR/dV amplitude (carrier concentration) and phase (carrier type) can be obtained. (See details in supplementary material is available online at stacks.iop.org/JPCO/2/025013/mmedia.) Furthermore, any stray field contribution from the non-tip part (i.e. cantilever and base) is essentially constant during a single scan. The effect of stray capacitance can be removed by simulations.

In this letter, the AFM, Asylum Research MFP-3D Infinity (under ambient condition) was used. Microwave (3 GHz) imaging was performed with a ScanWave (Prime Nano, Inc.) sMIM add-on unit installed on the AFM. The sMIM microwave output power was set to 100 mW. Fully shielded sMIM cantilever probes had spring constants in a range 1–2 N m−1. The CV curves were obtained in ambient with a home-made system, which combining the Dynamic Signal Analyzer (HF2LI, Zurich Instruments) with an Asylum MFP-3D infinity.

Figure 2.

Figure 2. A schematic of MH-EFM setup. A metal-coated tip was used. Two scan passes are needed in this technique. In the first pass, amplitude at resonant frequency of probe fr is used as feedback to obtain the topography of sample. In the second pass (lift mode), an AC bias voltage with a ∼kHz frequency (fω) is applied between the tip and sample, and feedback is off. The amplitude of cantilever vibration at fω, f2ω and f3ω are obtained by Lock-in amplifier, named as Aω, A2ω and A3ω. Aω is proportional to surface potential, while A2ω has relation with dielectric constant. The amplitude A3ω is corresponding to carrier concentration of the sample.

Standard image High-resolution image

MH-EFM is also a powerful tool to study the carrier concentration of semiconductor 2D materials [22] without adversely affected by stray capacitance, as shown in figure 2. In MH-EFM, dual pass mode was used to detect topography and electrical properties of sample. In first pass, the AFM works the same way as the typical AC mode (tapping model). In second pass (lift mode), short-range repulsive forces and the van der Waals force can be ignored because the tip–sample distance is large enough; meanwhile an AC voltage with a frequency of fω is applied between the tip and sample, resulting in multi-harmonic electrostatic force. The electrical force is as follows:

Equation (1)

Accordingly, the second and third harmonic component given by:

Equation (2)

Equation (3)

Therefore, the information corresponding to $\tfrac{\partial C}{\partial z}$ and $\tfrac{\partial C}{\partial V}$ can be obtained by detecting the 2ω and 3ω components. In another word, the amplitude of cantilever vibration (A2ω and A3ω) can reflect the capacitance (or dielectric constant) and carrier concentration of the sample, respectively [3638]. Furthermore, the A3ω has been amplified greatly by a resonance phenomenon. Specifically, resonant frequency of probe f0 is about 72 kHz; so we setting the frequency of applied AC voltage fω = f0/3 ∼ 24 kHz. By setting the frequency in such way, f3ω is coincident with the free resonance frequency of cantilever. It should be noted that the theory of MH-EFM is also applicable when f3ω located at non-resonance frequency. In this letter, we set f3ω at probe resonance frequency in order to get better sensitivity.

In this paper, the MH-EFM imaging were performed in ambient with a home-made system, which combining the Dynamic Signal Analyzer (HF2LI, Zurich Instruments) with an Asylum MFP-3D infinity. Metal coated probe are used in this mode.

The above studies proved that MH-EFM and sMIM can both profile the carrier concentration of semiconductors. In order to exhaustive delineation of the carrier concentration characterization by these two modes, several typical samples have been chosen to investigate here. Firstly, a standard n-type doped Si sample was used as a representative of traditional semiconductor material. Then, mechanical exfoliation and CVD grown molybdenum disulfide (MoS2) layers are chosen as the representative of 2D semiconductor materials. Furthermore, the penetration depth of these two modes has been studied by suspended MoS2 over circular holes arrays. During the experiment, all the samples are grounded. The experimental results are shown in the following parts.

3. Results

3.1. Traditional semiconductor material

Here, a traditional semiconductor material—standard n-type doped Si sample with different dopant concentration has been studied systemically. This standard sample is provided by Prime Nano. The dopant concentration of sample is different: the lower area is highly doped area (nominal ∼1021 cm−2), the center of higher strip area is light doped (nominal ∼1015 cm−2). (See details in supplementary material.)

Figure 3(a) shows the topography of doped Si sample. Figure 3(b) shows the CV curves taken in sMIM mode. The CV curves acquired at different positions show quite different characteristics, which is attributed to the difference of dopant concentration in sample. In the CV curves, the depletion region (slope rapidly changed region) can be used to describe the carrier concentration of sample. The higher the slope is, the lower carrier concentration is, which agrees with the parameters of the given sample.

Figure 3.

Figure 3. (a) Topography of standard N-doped Si sample. Heavy doped (nominal ∼1021 cm−2) region is lower than light doped (nominal ∼1015 cm−2) area. (b) The CV curves at different positions, which are marked by the color dots in (a). (c)–(e) Series of dC/dV amplitude images with different tip bias VG taken in sMIM mode. (f)–(h) Series of amplitude A3ω images with different tip bias VG taken in MH-EFM mode. All the scale bars are 2 μm.

Standard image High-resolution image

The dC/dV amplitude images with different tip bias VG taken in sMIM mode are shown in figures 3(c)–(e). The contrast between lower doped and higher doped regions can be seen clearly when VG is 1.2 V, while it is invisible when VG is 3 and −2V. Since dC/dV can be seen as the slope of CV curve, the behavior of dC/dV amplitude can be understood derived from the CV curves. When VG is 1.2 V, the slop of CV curve is significant different for different doping areas, and this resulting in the strong contrast of light dopant regions, as shown in figure 3(d). However, when VG larger than 3 V or smaller than −2 V, the slopes of all the CV curves are basically same (slopes are all approximately zero), so there is no contrast can be seen between high doped and less doped regions, as show in figures 3(c) and (e).

Figures 3(f)–(h) show amplitude A3ω images taken in MH-EFM mode with different gate voltages. The contrast of light or heavy doped areas is different when VG changes from −2 to 3 V. When VG is 1.2 V, the contrast of light doped area is brighter than that of heavy doped areas, shown as figure 3(g). However, there is no contrast can be seen when VG is 3 and −2 V. In MH-EFM, the sample is under low-frequency AC modulation, the carriers are driven in and out of the area underneath the tip. Although the electric field distributions around sample are not strictly same in MH-EFM and sMIM modes, the modulated A3ω signals are basically consistent with our observation in sMIM mode.

3.2. 2D semiconductor materials

2D MoS2, as a member of transition metal dichalcogenides, has shown promising potential in next generation optoelectronic and electrical devices due to its unique optical and electrical properties. Synthesis of few layers MoS2 has obtained a huge development, such as mechanical exfoliation, solution-based exfoliation, vapor-phase growth [39]. Here both the mechanical exfoliation and CVD grown MoS2 are chosen as our sample. Firstly, the MoS2 flakes obtained by mechanical exfoliation using adhesive tape (Scotch) and transferred to SiO2/Si substrate has been studied.

Figure 4(a) shows the topography of mechanical exfoliation MoS2 flakes. The topography profiling and Raman spectroscopy [40] (figure S3) show that the thickness of MoS2 changes from two layers (2L) to bulk, marked in figure 4(a).

Figure 4.

Figure 4. (a) Topography of MoS2 flakes on SiO2/Si. (b) Lumped element model with cantilever-sample stray impedance Zstr and sample admittance Zsample. (c) The CV curves taken at different positions, which are marked by the color dots in (a). (d)–(f) Series of dC/dV amplitude images with different tip bias VG taken in sMIM mode. (g)–(i) Series of A3ω images with different tip bias VG taken in MH-EFM mode. All the scale bars are 1 μm.

Standard image High-resolution image

The sMIM characterize of few layers MoS2 are shown here. The lumped element model [41] between tip and sample is shown in figure 4(b). Considering the following parts are also use MoS2 as sample, the lumped element model is also applicable for figure 5. The CV curves taken at different positions are demonstrated in figure 4(c). The sMIM-Im value of substrate (SiO2/Si) does not change with the gate voltages, showing an insulator behavior. The CV curves taken on MoS2 flakes show that the MoS2 flakes are n-type doped, and the carrier concentration is different for different thickness. It shows that the carrier concentration of 2L and bulk MoS2 are larger than that of three layers (3L) MoS2. Besides the influence of layer thickness, local carrier concentration may be influenced by interfacial impurities, strain, disorders and charge transfer [42, 43].

Figure 5.

Figure 5. (a) Topography of CVD-grown MoS2 on SiO2/Si substrate. (b) The corresponding sMIM-Im image of MoS2 taken in sMIM mode. (c) The CV curves taken at different positions, which are marked by the arrows in (a). The CV curves are shifted vertically in order to see it clearly. (d), (e) Topography and A2ω images of typical CVD-grown MoS2. (f) The close-up topography image of the pyramid-shaped flakes central part. (g)–(i) Series of A3ω images with different tip bias VG taken in MH-EFM mode.

Standard image High-resolution image

Figures 4(d)–(f) are dC/dV amplitude images with different tip bias VG, which are taken in sMIM mode. Comparing to the substrate, the contrast of 2L, 3L and bulk MoS2 flakes all can be seen clearly when VG is −5 V, while 2L and bulk regions became weaker when VG is 0 V and disappear when VG is 5 V. The behavior of dC/dV amplitude can be easy interpreted by the CV curves. When VG is −5 V, the slop of CV curves are similar for different thickness MoS2 layers and significant different from substrate. So the contrast between MoS2 layers is small and the contrast between MoS2 and substrate is large. When VG = 5 V is applied, the slopes of CV curves at 2L and bulk layers are similar to substrate, so there is no contrast can be seen between substrate, 2L and bulk MoS2, as shown in figure 4(f). However, the slope of CV curve at 3L MoS2 is larger than others region at VG = 5 V, so the contrast of 3L is much brighter than others regions.

Figures 4(g)–(i) show A3ω images of MoS2 flakes obtained in MH-EFM mode, and the gate voltages are marked in it. The contrast of them is different when VG changes. However, the change is absolutely different from the data obtained by sMIM mode, and it is hard to understand. The reasons will be discussed in the following Discussions parts.

Expect the mechanical exfoliation samples, the CVD grown MoS2 flakes [4446] has been studied by sMIM and MH-EFM. The MoS2 flakes were grown on SiO2 (300 nm)/Si substrate, via traditional CVD method.

The MoS2 flakes have a mixed zigzag/armchair edges because the edges are not straight [47], as shown in figures 5(a) and (d). These flakes can be divided into two different kinds: the purely uniform monolayer (marked by red arrow) and pyramid-shaped flakes (marked by blue arrow). The formation of different structures may be origin from different defects and dislocation concentration, i.e. screw dislocation can result in pyramid-shaped flakes [48].

These two kinds of sample have different contrast in sMIM-Im image, as shown in figure 5(b). The monolayers are hard to be distinguished from substrate, while the pyramid-shaped flakes are easy to be seen. The reason is that the thickness of monolayer is too small, so that the reflection microwave mainly reflecting the properties of substrate, other than properties of monolayers MoS2. Meanwhile, the pyramid-shaped flakes thick enough, so the electrical properties of pyramid-shaped flakes can be obtained by sMIM.

It is known that the conductivity of pyramid-shaped flakes is larger than monolayer because of the decreased band gap or dislocation [48, 49]. Hence, the difference of conductivity between pyramid-shaped MoS2 and substrate results in the sMIM contrast [46]. Classically, the sMIM-Im is corresponding to the dielectrics of sample. One may ignore the sMIM-Im can also indicate the conductivity of sample. According to the finite-element analysis (FEA) in [46], we can see the sMIM-Im is relating to electrical conductivity. And the lower the sMIM-Im is, the lower conductivity is. So we believe the sMIM-Im contrast (in figure 5(b)) of different thickness MoS2 derived from their conductivity.

Figure 5(c) shows the CV curves taken at substrate, monolayer and pyramid-shaped flakes, respectively. The sMIM-Im value of substrate does not change with the gate voltages, showing an insulator behavior. The CV curve of monolayer is basically same as the substrate, which confirms the reflection microwave on monolayers mainly reflecting the properties of substrate. However, the CV curve of pyramid-shaped flakes shows n-type semiconductor behavior.

Figures 5(d) and (e) show the simultaneously obtained topography and A2ω images of sample taken in the MH-EFM mode. In the A2ω image, the brighter the contrast is, the more quantity mobile charge is. The brighter contrast of the MoS2 layers represents they have more mobile charges, in contrast with the simple dielectric response of insulating SiO2 substrate. Furthermore, it can be seen the contrast of pyramid-shaped MoS2 is brighter than that of monolayer sample. This suggests the conductivity of the pyramid-shaped MoS2 is larger than monolayer, which is consists with previously works [48, 49].

Figures 5(g)–(i) show A3ω images of sample with different gate voltages taken in MH-EFM mode. The contrast of uniform monolayer does not change with the gate voltage, while that of pyramid-shaped flakes changes a lot as the gate voltage changing. It means that, in pyramid-shaped flakes, locally mobile charge carriers of sample can be modified by VG. The uneven contrast in figure 5(g) suggests defects and adsorptions existed near the triangular vertex of a small crystal, resulting in the mobile carrier distribution not uniform. Comparing the experimental data taken in these two modes, one can find that the MH-EFM is more sensitive than the sMIM for CVD grown MoS2 layers. The high sensitivity may be derived from the linear dielectric response form and signal amplified by a resonance phenomenon.

3.3. Sub-surface capability: MoS2 over SiO2/Si with circular holes arrays

In order to study sub-surface capability of these two modes, the MoS2 flake over SiO2/Si with circular holes arrays has also been studied. Briefly, the SiO2/Si substrate patterned with different diameter holes defined by e-beam lithography. Then mechanical exfoliation MoS2 flakes have been transferred onto the substrate to form suspended MoS2.

Figure 6(a) shows topography image of locally suspended MoS2 membranes over holes arrays. Thickness of the MoS2 layers is uniform ∼30 nm. The buried holes cannot be seen in the topography, however, they can be observed in sMIM-Im image, as shown in figure 6(b). Although the thickness of MoS2 is uniform, sMIM-Im signal of sample is not homogeneous. The sMIM signal near MoS2 edge is stronger than the central region of sample.

Figure 6.

Figure 6. (a) Topography of MoS2 flake transferred onto prepatterned SiO2/Si substrate containing arrays of circular holes. The red circles represent positions of holes. (b) The sMIM-Im image of MoS2. (c) The CV curves at different positions, which is marked by the color dots in (b). (d)–(f) Series of dC/dV amplitude images with different tip bias VG taken in sMIM mode. (g), (h) Series of A3ω images with different tip bias VG taken in MH-EFM mode. All the scale bars are 5 μm.

Standard image High-resolution image

Figure 6(c) shows the CV curves taken at different positions, which are marked by the color dots in figure 6(b). The CV curves indicate that the carrier concentration of MoS2 flakes is non-uniform. The carrier concentration difference may be resulting from strain, interfacial impurities, disorders and charge transfer [42, 43]. Figures 6(d)–(f) are dC/dV amplitude images with different tip bias VG taken in sMIM mode. The dC/dV amplitude contrast of whole MoS2 is uneven, which confirm the difference of carrier concentration in MoS2 flakes. The dC/dV images show the same physics as the CV curve, i.e. when VG is 5 V, the same contrast of the central region of MoS2 and substrate (include exposed holes) means the slope of CV curves at these areas are same.

Figures 6(g)–(i) show A3ω images of sample with different gate voltages taken in MH-EFM mode. The buried holes can also be observed in figures 6(g), (h), which indicate the MH-EFM also has sub-surface scanning ability. According to our experimental data, the penetration depth of MH-EFM method at least can reach to 75 nm (see details in supplementary material), which agrees with previously work [50]. The reason is that electrostatic fore is long-range interaction force. The contrast in A3ω images changes for different VG. However, the change is absolutely different from the data obtained by sMIM mode. The reasons will be discussed in the following Discussions parts.

4. Discussions

Theoretically and experiment results of sMIM and MH-EFM modes have been performed. They both can profile the carrier concentration of sample, and have sub-surface scanning ability. They also have advantages in sample preparation. Contact electrodes are not required and insulating or electrically isolated samples can readily be studied.

The difference and (dis)advantages of these two modes are further discussed here. Firstly, the basic mode of sMIM and MH-EFM are different. The sMIM can be implemented in both contact mode and AC mode, while the MH-EFM is implemented in AC mode [11, 51]. In our work, all the sMIM data is obtained at contact mode since better signal-to-noise ratio and more physical quantity can be obtained. More importantly, the basic mode may have great influence on the experiment data. The MH-EFM data is likely to be affected by charges in moisture adhered to the sample as well as in the ambient air around the tip, both of which are potential sources of alterations in charge distribution. Conversely, in sMIM mode (contact mode), tip makes direct contact with the sample surface by penetrating through any moisture layer, producing a point of direct contact, which is less likely to be influenced by parasitic charges from the scanning environment.

Secondly, the physics quantities extracted by the two methods are different. The MH-EFM can extract surface potential, capacitance and carrier concentration qualitatively. While the conductivity, permittivity, carrier type and concentration can be extracted quantitatively combining the FEA with spectroscopy study (i.e. CV, RV and Cz curves) in sMIM mode [11, 46, 52, 53].

Thirdly, detection sensitivity would be different for the determined carrier concentration. The dielectric response form may effect on the detection sensitivity. The dielectric response (the relationship between capacitance and dielectric constant, Cε) has different form in these two modes. The dielectric response is linear in MH-EFM, while it is nonlinear in sMIM mode. Expect the influence of dielectric response form, signal amplified by a resonance phenomenon improve the detection sensitivity in MH-EFM mode. So the sensitivity is different for the determined carrier concentration. Note that the A3ω images sometimes even has better sensitivity than sMIM mode, as shown in figure 5.

5. Conclusions

The mobile charge carriers profiling of several samples has been investigated by MH-EFM and sMIM, respectively. These two modes both enable provide carriers concentration imaging and have sub-surface sensitivity. The dielectric response form and parasitic charges in scanning environment may result in difference of the two kinds of methods. The techniques described in this study will effectively promote research on basic science and semiconductor applications.

Acknowledgments

This project is supported the Ministry of Science and Technology (MOST) of China (No. 2016YFA0200700), the Natural Science Foundation of China (NSFC) (No. 21622304, 61674045, 11604063), Key Research Program of Frontier Sciences, CAS (No. QYZDB-SSW-SYS031) and Osaka University's International Joint Research Promotion Program (J171013014, J171013007). Z H Cheng was supported by Distinguished Technical Talents Project and Youth Innovation Promotion Association CAS.