Paper The following article is Open access

Structural Health Monitoring Issues Using Inclinometers on Prestressed Concrete Girder Bridge Decks

, and

Published under licence by IOP Publishing Ltd
, , Citation Gabriele Bertagnoli et al 2021 IOP Conf. Ser.: Mater. Sci. Eng. 1203 032101 DOI 10.1088/1757-899X/1203/3/032101

1757-899X/1203/3/032101

Abstract

In the last decades, assessment and rehabilitation of the existing built environment constitute one of the major challenges for engineers, practitioners and code-makers all over the world. Aging, deterioration processes, lack of or improper maintenance, and increasing occurrence of extreme events have led to the need of more efficient methods for the safety assessment and retrofitting/rehabilitation of existing concrete structures like bridges. New approaches deriving from research should be able to provide solutions devoted to reduce and/or avoid the necessity of interventions, verifying the safety conditions for human life and performances for serviceability on aged infrastructures. Structural Health Monitoring (SHM) of existing bridges has become a key issue in all western world as most of the infrastructures of each Country are reaching the end of their design life. SHM can be divided classically in two approaches: static and dynamic. Static SHM is based on the measure of displacements and their derivatives like rotations or strains regardless of the dynamic behaviour of the structure. Clinometers are among the most used devices to measure angles on structures; they can provide high accuracy when used in static mode as advanced techniques of signal processing can be used to reduce the noise of the signal working on acquisitions that can last several seconds to provide one single accurate measure of angle. Nevertheless, many issues one the affidability and the correct use of measures done with clinometers have to be addressed to achieve a trustworthy SHM using such devices. In this paper the most relevant issues related to the f.e.m. modelling of a bridge deck in view of the use of clinometers for SHM are presented providing explanation using a test case bridge that has been under continuous investigation for many months. A brief explanation of the process for data cleaning and interpretation is also given, stressing out the limits of the technology and the possible outcomes.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.
10.1088/1757-899X/1203/3/032101