A precooled Joule-Thomson (J-T) cooler refrigerates at liquid helium temperature. Its third stage heat exchanger works below 20 K. Hot fluid cannot be sufficiently cooled due to nonidealism of the heat exchanger and helium-4 properties. In a J-T cycle of low pressure ratio, the heat exchanger with bypass and throttling improves the refrigeration capacity. Bypass and throttling reduces the temperature difference and entropy generation within the heat exchanger.