Paper The following article is Open access

Using In-situ Cryogenic Radiometers to Measure the Performance of a Large Thermal Vacuum Chamber

, , , , , , and

Published under licence by IOP Publishing Ltd
, , Citation Michael DiPirro et al 2015 IOP Conf. Ser.: Mater. Sci. Eng. 101 012129 DOI 10.1088/1757-899X/101/1/012129

1757-899X/101/1/012129

Abstract

The James Webb Space Telescope will operate in space at temperatures lower than 50 K. To test the major parts of the telescope and instruments on the ground requires a very large thermal vacuum chamber with a helium-cooled shroud operating below 20 K. This chamber and shroud are being subjected to a series of 4 preliminary tests to characterize the chamber and the ground support equipment before the telescope and instruments are tested. We have made measurements in the first of these preliminary tests using simple radiometers, which are located in the chamber and are pointed at various locations and items of interest within the chamber. The radiometers, which have been previously described[1], consist of a Cernox thermometer attached to an absorber suspended behind a Winston cone with an acceptance half-angle of 11 degrees. 9 of these radiometers were anchored to the chamber at temperatures between 17 and 25 K and were able to resolve 2 mW over an area of one m2. This level of sensitivity corresponds to a 60 K blackbody, which spans the radiometer field of view, changing in temperature by 0.04 K. The results of this test and plans for future tests will be described.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.
10.1088/1757-899X/101/1/012129