Properties of a two stage adiabatic demagnetization refrigerator

, , , , , and

Published under licence by IOP Publishing Ltd
, , Citation H Fukuda et al 2015 IOP Conf. Ser.: Mater. Sci. Eng. 101 012047 DOI 10.1088/1757-899X/101/1/012047

1757-899X/101/1/012047

Abstract

Currently, many space missions using cryogenic temperatures are being planned. In particular, high resolution sensors such as Transition Edge Sensors need very low temperatures, below 100 mK. It is well known that the adiabatic demagnetization refrigerator (ADR) is one of most useful tools for producing ultra-low temperatures in space because it is gravity independent. We studied a continuous ADR system consisting of 4 stages and demonstrated it could provide continuous temperatures around 100 mK. However, there was some heat leakage from the power leads which resulted in reduced cooling power. Our efforts to upgrade our ADR system are presented. We show the effect of using the HTS power leads and discuss a cascaded Carnot cycle consisting of 2 ADR units.