Paper The following article is Open access

Dynamic response and failure mode of series isolation system under explosion load

, , and

Published under licence by IOP Publishing Ltd
, , Citation Wang Yanan et al 2021 IOP Conf. Ser.: Earth Environ. Sci. 791 012139 DOI 10.1088/1755-1315/791/1/012139

1755-1315/791/1/012139

Abstract

The numerical model of the series isolation structure was established by using the finite element software to simulate the dynamic behavior of the series isolation structure after explosions occurred at different positions, and study the dynamic response and failure mode of the series isolation structure under explosion load. The results show that the vertical displacement and speed of the beams on each floor show a certain regularity with the passage of time. When columns at different positions encounter explosive loads, they will cause local collapse and damage of the structure, and the damage is mainly distributed in the longitudinal and transverse ranges where the columns are located. Compared with the inner column, the structural damage caused by the explosion load on the corner column and side column is more serious.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.
10.1088/1755-1315/791/1/012139