Abstract
This article presents the methodology and results of experimental studies of the parameters of the electrode system "Potential plane with corona needles - grounded plane". The parameters of the electrode system were determined for a distance between the electrodes of 0.15 m. The parameters of the electrode system determined on the basis of these studies were verified on the basis of experimental studies of the process of trapping dust particles from an air stream. The methodology and analysis of the results of these studies are given. Based on these studies, the best ratios of the parameters of the electrode system were determined according to the highest degree of purification of the cleaned air. The difference in the distances between the needles in a row located perpendicular to the flow of the cleaned air and between the rows of needles is determined.
Export citation and abstract BibTeX RIS
Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.