This site uses cookies. By continuing to use this site you agree to our use of cookies. To find out more, see our Privacy and Cookies policy.
technical report

Traceable dosimetry for MeV ion beams

, and

Published 8 February 2022 © 2022 IOP Publishing Ltd and Sissa Medialab
, , Citation G. Garty et al 2022 JINST 17 T02002 DOI 10.1088/1748-0221/17/02/T02002

1748-0221/17/02/T02002

Abstract

Standard dosimetry protocols exist for highly penetrating photon and particle beams used in the clinic and in research. However, these protocols cannot be directly applied to shallow penetration MeV-range ion beams. The Radiological Research Accelerator Facility has been using such beams for almost 50 years to irradiate cell monolayers, using self-developed dosimetry, based on tissue equivalent ionization chambers. To better align with the internationally accepted standards, we describe implementation of a commercial, NIST-traceable, air-filled ionization chamber for measurement of absorbed dose to water from low energy ions, using radiation quality correction factors calculated using TRS-398 recommendations. The reported dose does not depend on the ionization density in the range of 10–150 keV/μm.

Export citation and abstract BibTeX RIS

10.1088/1748-0221/17/02/T02002