paper

Calibration method for sway error of three-axis fluxgate

, , , , and

Published 11 August 2021 © 2021 IOP Publishing Ltd and Sissa Medialab
, , Citation L. Xu et al 2021 JINST 16 T08012 DOI 10.1088/1748-0221/16/08/T08012

1748-0221/16/08/T08012

Abstract

Aiming at the problem that attitude changes will cause sway errors of the fluxgate, firstly, the attitude change error model is constructed theoretically, and the influence of attitude changes on the three-axis fluxgate is analyzed; secondly, in order to improve measurement accuracy of the fluxgate, reduce the measurement error caused by the change of attitude, the calibration method for sway error of fluxgate is proposed. Furthermore, the error calibration model is established. Finally, the effectiveness of the method is verified by simulation and actual experiment. The uniaxial absolute error can be up to 4.64% at a minimum. The calibration effect is good, and the calibrated data can basically meet actual needs.

Export citation and abstract BibTeX RIS