The International School for Advanced Studies (SISSA) was founded in 1978 and was the first institution in Italy to promote post-graduate courses leading to a Doctor Philosophiae (or PhD) degree. A centre of excellence among Italian and international universities, the school has around 65 teachers, 100 post docs and 245 PhD students, and is located in Trieste, in a campus of more than 10 hectares with wonderful views over the Gulf of Trieste.

SISSA hosts a very high-ranking, large and multidisciplinary scientific research output. The scientific papers produced by its researchers are published in high impact factor, well-known international journals, and in many cases in the world's most prestigious scientific journals such as Nature and Science. Over 900 students have so far started their careers in the field of mathematics, physics and neuroscience research at SISSA.

Visit www.sissa.it

.

Energy deposition measurements of single 1H, 4He and 12C ions of therapeutic energies in a silicon pixel detector

, , , , , , , and

Published 21 April 2017 © 2017 IOP Publishing Ltd and Sissa Medialab srl
, ,

1748-0221/12/04/P04025

Abstract

In the field of ion-beam radiotherapy and space applications, measurements of the energy deposition of single ions in thin layers are of interest for dosimetry and imaging. The present work investigates the capability of a pixelated detector Timepix to measure the energy deposition of single ions in therapeutic proton, helium- and carbon-ion beams in a 300 μm-thick sensitive silicon layer. For twelve different incident beams, the measured energy deposition distributions of single ions are compared to the expected energy deposition spectra, which were predicted by detailed Monte Carlo simulations using the FLUKA code. A methodology for the analysis of the measured data is introduced in order to identify and reject signals that are either degraded or caused by multiple overlapping ions. Applying a newly proposed linear recalibration, the energy deposition measurements are in good agreement with the simulations. The twelve measured mean energy depositions between 0.72 MeV/mm and 56.63 MeV/mm in a partially depleted silicon sensor do not deviate more than 7% from the corresponding simulated values. Measurements of energy depositions above 10 MeV/mm with a fully depleted sensor are found to suffer from saturation effects due to the too high per-pixel signal. The utilization of thinner sensors, in which a lower signal is induced, could further improve the performance of the Timepix detector for energy deposition measurements.