Paper The following article is Open access

Operational tests of CRYRING@ESR without electron cooler solenoid compensation

, , , , , , , , , , , , and

Published under licence by IOP Publishing Ltd
, , Citation C Krantz et al 2024 J. Phys.: Conf. Ser. 2687 052026 DOI 10.1088/1742-6596/2687/5/052026

1742-6596/2687/5/052026

Abstract

We have tested operation of FAIR's low-energy ion storage ring CRYRING@ESR with uncompensated electron cooler solenoid. With its standard working point on the lowest-order difference resonance, a second solenoid is normally used to cancel betatron coupling introduced by the cooler's magnetic field. In operation with a D+ test beam, we found that omission of the compensation solenoid did not lead to a notable deterioration of beam intensity, quality, or cooling time, though the expected coupling of betatron motion is then clearly observed.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.
10.1088/1742-6596/2687/5/052026