Heat and Moisture Modelling of Vacuum Insulated Retrofits with Experimental Validation

, and

Published under licence by IOP Publishing Ltd
, , Citation B Conley et al 2021 J. Phys.: Conf. Ser. 2069 012035 DOI 10.1088/1742-6596/2069/1/012035

1742-6596/2069/1/012035

Abstract

Vacuum insulation panels (VIPs) offer 8-10 times the thermal resistance of fiberglass insulation and would fit the need for a low conductivity exterior insulation. A composite insulation panel using VIPs encased in rigid foam was developed, built, and tested. Two different sizes of VIPs were used for that stage of the project, and after monitoring and evaluation, they showed contrasting results. A simulation study was performed to find the optimal VIP solution that maximized the effective thermal conductivity and minimized the mould growth potential. In total, 5 wall assemblies with VIPs used as the exterior insulation were simulated using WUFI and WUFI2D. The simulations showed that the humidity levels at the inside face of the OSB inboard of the VIPs decreased when 200 mm by 300 mm VIPs were used, but they did not reach the thermal performance thresholds of R5.28 m2K/W. The hygrothermal analysis showed that under similar conditions, a VIP insulated wall assembly would have a lower relative humidity at the sheathing surface compared to EPS and XPS. The one-and two-dimensional simulations were compared and found that WUFI Pro was capable to evaluate a VIP-insulated wall assembly.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.
10.1088/1742-6596/2069/1/012035