Abstract
In order to solve the problem of oil leakage at the flange bolted connection of the casing of combustion chamber, an implementation solution was proposed in this paper. Firstly, a simplified flange bolted connection finite element model was established in ANSYS based on the actual size of the casing. Then, the deformation of the flange joint surface under two different forms of load was analyzed. Finally, according to calculation results, the suggestion of adding gasket was proposed to improve sealing performance of casing, and the sealing effect of gaskets of different thicknesses is also studied. This article provided a reference for improving the oil leakage problem of the casing flange bolted connection.
Export citation and abstract BibTeX RIS
Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.