Paper The following article is Open access

3D Detectors on Hydrogenated Amorphous Silicon for particle tracking in high radiation environment

, , , , , , , , , , , , and

Published under licence by IOP Publishing Ltd
, , Citation M Menichelli et al 2020 J. Phys.: Conf. Ser. 1561 012016 DOI 10.1088/1742-6596/1561/1/012016

1742-6596/1561/1/012016

Abstract

The vertex detectors for the future hadronic colliders will operate under proton fluencies above 1016 p/cm2. Crystalline Silicon detector technology, up to now, has kept the pace of the increasing fluencies in the LHC era and it is still the prevalent vertex detector material for the present and for the immediate future. Looking ahead in time, an alternative solution for such a detector has to be found because for the future there is no guarantee that Crystalline Silicon will hold this challenge. For this reason the development of hydrogenated amorphous silicon vertex detectors based on 3D-technology have been proposed and the technological solutions in order to build these detectors are described in this paper.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.
10.1088/1742-6596/1561/1/012016