The Data-Acquisition System with Cluster-Finding Trigger at the J-PARC KOTO Experiment

, , , , and

Published under licence by IOP Publishing Ltd
, , Citation C Lin et al 2020 J. Phys.: Conf. Ser. 1526 012034 DOI 10.1088/1742-6596/1526/1/012034

1742-6596/1526/1/012034

Abstract

In order to collect the events efficiently with a high intensity beam, we built a new trigger electronics system based on the calibrated energy information and the number of electromagnetic shower clusters in the calorimeter for the J-PARC KOTO experiment. The dead time of this system is 0.16 µs and the loss was measured to be less than 1%. By performing the online clustering algorithm on the simulated data, the trigger efficiency for the primary mode ${K}_{L}\to {\pi }^{0}\nu \bar{\nu }$ is estimated to be 99.6%.