Synopsis
We present experimental mass stopping powers of electrons in gaseous H2 obtained with a newly developed electron time-of-flight spectrometer, for the incident electron energy range of 10 eV to 25 eV. In our procedure the average energy loss is derived from our conversion of measured electron time-of-flight spectra into equivalent electron energy loss spectra so as to obtain the values of mass stopping power for electron scattering from H2.