Weight and size characteristics modelling of the power plants contact condensers

, , , , and

Published under licence by IOP Publishing Ltd
, , Citation A N Mrakin et al 2019 J. Phys.: Conf. Ser. 1210 012100 DOI 10.1088/1742-6596/1210/1/012100

1742-6596/1210/1/012100

Abstract

The article presents the fundamental principles of mixing condensers calculation. The design calculation flow chart of apparatuses of this type is proposed. A good convergence of the droplet motion hydromechanics with the other authors works results is identified. The operating conditions calculation results of the contact condenser as a part of the chemical energy unit with hydrocarbon raw material partial oxidation showed that mass transfer impact on the heat exchange is quite significant (the Gukhman criterion is 0.0076), which affects the high process intensity (heat transfer coefficient is ∼179 W/(m2·°C)). However, as expected, the device is characterized by the low resistance of ∼6 Pa.

Export citation and abstract BibTeX RIS