Comparison of ozone production by DBDP reactors: difference external electrodes

, , , , , , and

Published under licence by IOP Publishing Ltd
, , Citation E Yulianto et al 2019 J. Phys.: Conf. Ser. 1153 012088 DOI 10.1088/1742-6596/1153/1/012088

1742-6596/1153/1/012088

Abstract

Research on ozone generator performance technology of dielectric barrier discharge plasma (DBDP) has been conducted. The study was carried out by using two models of reactor configuration. The first model uses a wire mesh - aluminum foil configuration. The second model uses the wire mesh electrode configuration - wire mesh wrapped in aluminum foil. Ozone was generated using AC high Voltage. Oxygen that source of ozone has been taken from the water. The ozone was produced by DBDP reactor with voltage variation from 0.5 to 14 kV and a fixed air flow rate of 10 L / min. The first models of the reactor was Be Able to produce ozone of 138 ppm at a voltage of 14.3 kV with a maximum temperature of the inner reactor at 49 ° C. The second model of ozone produced with concentration of 163 ppm at a voltage of 14.2 kV and a maximum temperature of the inner reactor of 52 ° C. We found that reactor with wire mesh electrode configuration - wire mesh wrapped in aluminum foil can produce more high ozone concentration with the same voltage.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.