Modal identification of output-only systems using frequency domain decomposition

, and

Published under licence by IOP Publishing Ltd
, , Citation Rune Brincker et al 2001 Smart Mater. Struct. 10 441 DOI 10.1088/0964-1726/10/3/303

0964-1726/10/3/441

Abstract

In this paper a new frequency domain technique is introduced for the modal identification of output-only systems, i.e. in the case where the modal parameters must be estimated without knowing the input exciting the system. By its user friendliness the technique is closely related to the classical approach where the modal parameters are estimated by simple peak picking. However, by introducing a decomposition of the spectral density function matrix, the response spectra can be separated into a set of single degree of freedom systems, each corresponding to an individual mode. By using this decomposition technique close modes can be identified with high accuracy even in the case of strong noise contamination of the signals. Also, the technique clearly indicates harmonic components in the response signals.

Export citation and abstract BibTeX RIS

Please wait… references are loading.