This research describes the behaviour of equipment and safety devices during use in extreme environmental conditions, in order to establish the technical conditions and additional health and safety requirements during operation, to ensure the health and safety of users, regardless of conditions and working environment in which they are use. The studies have been conducted both on new equipment and means of protection used in electrical installations. There has been evaluated protective equipment made of insulating rubber, reinforced fiberglass or PVC. They have been followed the technical characteristics and protection against electric shock by measuring the leakage current of different insulating materials.