Abstract
The development of compact low profile gamma-ray detectors has allowed the production of small field of view, hand held imaging devices for use at the patient bedside and in operating theatres. The combination of an optical and a gamma camera, in a co-aligned configuration, offers high spatial resolution multi-modal imaging giving a superimposed scintigraphic and optical image. This innovative introduction of hybrid imaging offers new possibilities for assisting surgeons in localising the site of uptake in procedures such as sentinel node detection. Recent improvements to the camera system along with results of phantom and clinical imaging are reported.
Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 License. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
References
- [1]J. Duch, 2011 Portable gamma cameras: the real value of an additional view in the operating theatre, Eur. J. Nucl. Med. Mol. Imaging 38 633
- [2]J.E. Lees, D.J. Bassford, O.E. Blake, P.E. Blackshaw and A.C. Perkins, 2011 A high resolution Small Field Of View (SFOV) gamma camera: a columnar scintillator coated CCD imager for medical applications, JInst 6 C12033
- [3]M. Tsuchimochi and K. Hayama, 2013 Intraoperative gamma cameras for radioguided surgery: Technical characteristics, performance parameters, and clinical applications, Phys. Med. 29 126
- [4]S. Pitre et al., 2003 A hand-held imaging probe for radio-guided surgery: physical performance and preliminary clinical experience, Eur. J. Nucl. Med. Mol. Imaging 30 339
- [5]A. Ferretti et al., 2013 Phantom study of a new hand-held gamma-imaging probe for radio-guided surgery, Nucl. Med. Commun. 34 86
- [6]C. Trotta et al., 2007 New high spatial resolution portable camera in medical imaging, Nucl. Instrum. Meth. A 577 604
- [7]W. Siman and S.C. Kappadath, 2012 Performance characteristics of a new pixelated portable gamma camera, Med. Phys. 39 3435
- [8]P. Russo et al., 2011 Evaluation of a CdTe semiconductor based compact gamma camera for sentinel lymph node imaging, Med. Phys. 38 1547
- [9]P.D. Olcott et al., Performance Characterization of a Miniature, High Sensitivity Gamma Ray Camera, IEEE Trans. Nucl. Sci. 54 2007 1492
- [10]A. Abe et al., 2003 Performance evaluation of a hand-held, semiconductor (CdZnTe)-based gamma camera Eur. J. Nucl. Med. Mol. Imaging 30 805
- [11]e2v Technologies Ltd, 106 Waterhouse Lane, Chelmsford, Essex, CM1 2QU, U.K
- [12]Hamamatsu Photonics UK Limited, 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire, AL7 1BW, U.K
- [13]Ultimate Metals, 46 Larkshall Road, Chingford, London, E4 7HZ, U.K
- [14]A. MacDonald and S. Burrell, 2008 Infrequently performed studies in nuclear medicine: Part 1, J. Nucl. Med. Technol. 36 132
- [15]S. Salvador et al., 2007 Sentinel node imaging via lymphoscintigraphy, JInst 2 P07003
- [16]H.S. Koops et al., 1999 Sentinal node biopsy as a surgical staging method for solid cancers, Radiother. Oncol., 51 1
Citations
-
A novel compact small field of view hybrid gamma camera
Aik H. Ng et al 2017 Nuclear Medicine Communications 38 729 - Renato A. Valdés Olmos et al 2016 1
-
Assessment of the performance of small field of view gamma cameras for sentinel node imaging
Aik Hao Ng et al 2015 Nuclear Medicine Communications 36 1134