This site uses cookies. By continuing to use this site you agree to our use of cookies. To find out more, see our Privacy and Cookies policy.

The Daya Bay antineutrino detector filling system and liquid mass measurement

, , , , , , , , , , , and

Published 24 September 2013 © 2013 IOP Publishing Ltd and Sissa Medialab srl
, , Citation H R Band et al 2013 JINST 8 P09015 DOI 10.1088/1748-0221/8/09/P09015

1748-0221/8/09/P09015

Abstract

The Daya Bay Reactor Neutrino Experiment has measured the neutrino mixing angle θ13 to world-leading precision. The experiment uses eight antineutrino detectors filled with 20-tons of gadolinium-doped liquid scintillator to detect antineutrinos emitted from the Daya Bay nuclear power plant through the inverse beta decay reaction. The precision measurement of sin213 relies on the relative antineutrino interaction rates between detectors at near (400 m) and far (roughly 1.8 km) distances from the nuclear reactors. The measured interaction rate in each detector is directly proportional to the number of protons in the liquid scintillator target. A precision detector filling system was developed to simultaneously fill the three liquid zones of the antineutrino detectors and measure the relative target mass between detectors to < 0.02%. This paper describes the design, operation, and performance of the system and the resulting precision measurement of the detectors' target liquid masses.

Export citation and abstract BibTeX RIS

10.1088/1748-0221/8/09/P09015