A high precision Fabry-Perot cavity polarimeter at HERA

, , , , , , , , , , , , , , , , , , , , and

Published 28 June 2010 Published under licence by IOP Publishing Ltd
, , Citation S Baudrand et al 2010 JINST 5 P06005 DOI 10.1088/1748-0221/5/06/P06005

1748-0221/5/06/P06005

Abstract

A Fabry-Perot cavity polarimeter, installed in 2003 at HERA for the second phase of its operation, is described. The cavity polarimeter was designed to measure the longitudinal polarisation of the HERA electron beam with high precision for each electron bunch spaced with a time interval of 96 ns. Within the cavity the laser intensity was routinely enhanced up to a few kW from its original value of 0.7 W in a stable and controllable way. By interacting such a high intensity laser beam with the HERA electron beam it is possible to measure its polarisation with a relative statistical precision of 2% per bunch per minute. Detailed systematic studies have also been performed resulting in a systematic uncertainty of 1%.