Radiation hardness study of semi-insulating GaAs detectors against 5 MeV electrons

, , , , , and

Published 9 January 2018 © 2018 IOP Publishing Ltd and Sissa Medialab
, , 19th International Workshop on Radiation Imaging Detectors (IWORID2017) Citation A. Šagátová et al 2018 JINST 13 C01006 DOI 10.1088/1748-0221/13/01/C01006

1748-0221/13/01/C01006

Abstract

A radiation hardness study of Semi-Insulating (SI) GaAs detectors against 5 MeV electrons is described in this paper. The influence of two parameters, the accumulative absorbed dose (from 1 to 200 kGy) and the applied dose rate (20, 40 or 80 kGy/h), on detector spectrometric properties were studied. The accumulative dose has influenced all evaluated spectrometric properties and also negatively affected the detector CCE (Charge Collection Efficiency). We have observed its systematic reduction from an initial 79% before irradiation down to about 51% at maximum dose of 200 kGy. Relative energy resolution was also influenced by electron irradiation. Its degradation was obvious in the range of doses from 24 up to a maximum dose of 200 kGy, where an increase from 19% up to 31% at 200 V reverse voltage was noticed. On the other hand, a global increase of detection efficiency with accumulative absorbed dose was observed for all samples. Concerning the actual detector degradation we can assume that the tested SI GaAs detectors will be able to operate up to a dose of 300 kGy at least, when irradiated by 5 MeV electrons. The second investigated parameter of irradiation, the dose rate of chosen ranges, did not greatly alter the spectrometric properties of studied detectors.

Export citation and abstract BibTeX RIS

10.1088/1748-0221/13/01/C01006