Abstract
Simulation distribution of pollutants (SOx and NOx) emitted from Cirebon power plant activities have been carried out. Gaussian models and scenarios are used to predict the concentration of pollutant gasses. The purposes of this study were to determine the distribution of the flue gas from the power plant activity and differences pollutant gas concentrations in the wet and dry seasons. The result showed that the concentration of pollutant gasses in the dry season was higher than the wet season. The difference of pollutant concentration because of wind speed, gas flow rate, and temperature of the gas that flows out of the chimney. The maximum concentration of pollutant gasses in wet season for SOx is 30.14 µg/m3, while NOx is 26.35 µg/m3. Then, The simulation of air pollution in the dry season for SOx is 42.38 µg/m3, while NOx is 34.78 µg/m3.

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.