Design, modelling and preliminary characterisation of microneedle-based electrodes for tissue electroporation in vivo

, , , , and

Published under licence by IOP Publishing Ltd
, , Citation Conor O'Mahony et al 2016 J. Phys.: Conf. Ser. 757 012040 DOI 10.1088/1742-6596/757/1/012040

1742-6596/757/1/012040

Abstract

We analysed the use of microneedle-based electrodes to enhance electroporation of mouse testis with DNA vectors for production of transgenic mice. Different microneedle formats were developed and tested, and we ultimately used electrodes based on arrays of 500 μm tall microneedles. In a series of experiments involving injection of a DNA vector expressing Green Fluorescent Protein (GFP) and electroporation using microneedle electrodes and a commercially available voltage supply, we compared the performance of flat and microneedle electrodes by measuring GFP expression at various timepoints after electroporation. Our main finding, supported by both experimental and simulated data, is that needles significantly enhanced electroporation of testis.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.